| GENERIC | Configuration of Cabin | With one Room and Verandah., With one Room only., With one room, one kitchen and verandah, With three rooms, one kitchen and verandah, With one room - one toilet and one pantry, Hall with attached Room β 1 no, Conference Hall + attached Pantry β 1 no, One no. Toilet (comprising of 2 Urine pot, 1 Toilet Room with Sheet and 1 no. Wash basin) |
| GENERIC | Approval of Advance sample | No Advance Sample |
| GENERIC | Time period for completion of Erection work at site by seller | Within 30 days of the date of receipt of consignee's confirmation regarding completion of ground and foundation work |
| GENERIC | Suitability / structural stability / completness of structures, the structure is intended for use in | In wind condition of 55m/s - in Seismic zone V and ambient temprature range 0 degree C to (+) 50 degree C - Roof slope 1 : 2 Cabin should be structurally stable and suitable to meet severity of these climatic condition. |
| GENERIC | Type of slope(roof) | One way slope., Two way slope., All side slope., No Slope (self draining type roof) |
| GENERIC | Storage provision | 1 no. Wooden Cabinet, 1 no. Steel Almirah, N.A |
| GENERIC | Provision for Power Connection | The seller to be liable to get the Electric connection through 3 core insulated underground cable covered with MS pipe from the power supply point provided by the Buyer., The seller to be liable to get the Electric connection through 3 core insulated underground cable covered with PVC pipe from the power supply point provided by the Buyer., Provision for Power Connection not required., The seller to be liable for Electric Supply to Porta Cabin at one point only (suitable for 415 V 50 HZ for distribution of supply for various appliances) |
| GENERIC | Wiring | Concealed wiring, Surface wiring |
| GENERIC | Provision for Cable , Switches and Junction box connection | Seller to make appropriate provisions for cable laying - installing meter / junction box with switches - other related electrical accessories as may be require for the power supply to the Cabin., Provision for Cable, switches and Junction box Connection not required., Provision of PVC insulated copper wiring - PVC conduits - AC points - Switch - Sockets - Fluorescent lights/LED's - Fans - Exhaust fan and MCB, As per Buyerβs choice |
| GENERIC | Other requirements | All necessary required permissions from civic agencies for installation and commissioning to be arranged by seller - necessary assistance / documents required to be provided by Buyer., Not required. |
| PANEL MATERIAL | Side wall panel material | 1.25 mm thick corrugated HR sheet |
| PANEL MATERIAL | Door panel material | Panel made up of micro ribbing Pre-Painted Galvanized Iron Sheet on both sides(have tongue groove arrangement) and 50 mm thick composite PUF sandwich between Pre-Painted Galvanized Iron Sheet |
| PANEL MATERIAL | Window panel material | Powder coated aluminium sliding windows with 4 mm tinted Glass |
| PANEL MATERIAL | Door and Window canopy material | Fibreglass Reinforced plastics (F.R.P)., 18 gauge MS corrugated sheet., 1.25 mm thick corrugated HR sheet, N.A, As per Buyerβs choice |
| PANEL MATERIAL | Floor panels material | 24 mm Block board thickness with FRP coating checkers style., 19 mm thick marine grade plywood confmg. to IS 710 / latest to be laid on top and secured by self - tapping screws to the base members - Covered with 2 mm thick PVC sheets., 16 mm thick marine grade plywood with Vinyl carpet., 15 mm heavy duty cement fiber board inside and outside texture paint., 18 mm thick BWP plyboard mounted on top and above that PVC to be attached on above surface., BWP marine grade ply board 12 mm thick with PVC vinyl sheet on top., 18 mm plywood with 1.5 mm vinyl sheet, 18mm thick cement board with PVC Vinyl carpet top of at least 1.5mm thickness with suitable support on bottom |
| PANEL MATERIAL | Roof panel material | 18 gauge MS corrugated sheet |
| PANEL MATERIAL | Insulation material for sides and End walls | With 50 mm thick glass wool, With polyurethane foam (PUF) having density 40 Kg/CuM Β± 2 Kg / CuM., 30 mm high density thermocol., Resin bonded with EPS thermo-Cole 75 mm thick - sand casted and texture finish / color (outside only), N.A, With 50 mm thick Mineral wool, 50mm thick layer of PU foam of density of 40Β±2 kg / CuM as insulation, 40mm thick layer of PU foam of density of 40Β±2 kg / CuM as insulation |
| PANEL MATERIAL | Insulation material for Roof | With 75 mm thick glass wool, With polyurethane foam (PUF) having density 40 Kg/CuM Β± 2 Kg / CuM, 30 mm high density thermocol., Resin bonded with EPS thermo-Cole 75 mm thick - sand casted and texture finish / color (outside only), N.A, 50mm thick layer of PU foam of density of 40Β±2 kg / CuM as insulation, 40mm thick layer of PU foam of density of 40Β±2 kg / CuM as insulation |
| PANEL MATERIAL | Inside panel material for sides, end walls & roof | Consists of 8 mm thick pre-laminated board., Wall internal cladding by 50 mm thick glasswood with 6 mm prelaminated plywood (having colour as per buyer's choice) - fixed with aluminium stiffener and rivets, N.A, The interior shall be aesthetically finished. All vertically and horizontal corners shall be neatly and smoothly finished with suitable Aluminum sections. All inner paneling shall be done by decorative laminated board |
| FRAME MATERIAL | Roof frame | Made of MS having stiffner Top 40 mm x 20 mm x 3.2 mm thick, Made of MS having stiffner Top 40 mm x 20 mm x 3.5 mm thick, Made of MS having stiffner Top 40 mm x 20 mm x 4 mm thick, Made of MS having stiffner Top 50 mm x 25 mm x 2.5 mm thick and 32 mm x 32 mm x 2 mm MS sq. tubes, Supported MS structure with Column - Truss - Portal truss - Purlin - Tie member, MS frame of 32 mm x 32 mm size 16 gauge square hollow tube section., Robust structural steel frame laced with cross members and corrugated steel panels, Top frame MS tube 80 mm X 80 mm (Materials of structural steel members shall conform to IS: 1079 Grade O/ IS: 2062 Grade A) |
| FRAME MATERIAL | Side Panel frame | Made of MS having stiffner Top 40 mm x 20 mm x 3.2 mm thick |
| FRAME MATERIAL | Floor panel frame | MS having 50 mm x 50 mm x 1.2 mm, MS having 50 mm x 50 mm x 1.5mm, MS having 50 mm x 50 mm x 2 mm, MS having 50 mm x 50 mm x 3 mm, To be made out with 1.2 mm MS folded section in required size and shape., MS frame of 32 mm x 32 mm size 16 gauge square hollow tube section., MS Tubular pipes of 50 mm x 50 mm heavy gauge., MS structure base frame C channel of size 125 mm x 75 mm and Base filling of MS tubular pipe of 80 mm x 40 mm, interconnecting MS pipe (Materials of structural steel members shall conform to IS: 1079 Grade O/ IS: 2062 Grade A) |
| Dimensions and Thickness | Inside Length Β± 15 mm | 1220 mm, 1525 mm, 1830 mm, 2135 mm, 2210 mm, 2440 mm, 3050 mm, 3960 mm, 6100 mm, 6000 mm, 12200 mm, 9000 mm, 12000 mm |
| Dimensions and Thickness | Inside Width Β± 15 mm | 1065 mm, 1220 mm, 1830 mm, 2135 mm, 2210 mm, 2440 mm, 3050 mm, 3660 mm, 1525 mm, 7620 mm, 3000 mm |
| Dimensions and Thickness | Total Height (mm) Β± 15mm | 2135 mm, 2285 mm, 2440 mm, 2590 mm, 2750 mm, 2895 mm, 2550 mm |
| Dimensions and Thickness | Roof projection (if any) Β± 10 mm | 305 mm to be given on all sides at full height of cabins., 300 mm from the Eaves wall and 150 mm from the Gable walls., 380 mm to be given on all sides at full height of cabins., N.A |
| Dimensions and Thickness | Total thickness of Wall panel Β± 2 mm | 75 mm, 47 mm, 40 mm, 30 mm, 20 mm, 15 mm, 50 mm, 55 mm |
| Dimensions and Thickness | Total thickness of Door panel Β± 2 mm | 40 mm, 35 mm, 30 mm, 20 mm, 15 mm, 50 mm |
| Dimensions and Thickness | Roof ridge height Β± 10 mm | Total height (i.e. height of side panels) + 610 mm, Total height (i.e. height of side panels) + 760 mm, N.A |
| Dimensions and Thickness | Almirah / Cabinet size Β± 5 mm | 760 mm x 405 mm x 750 mm, 760 mm x 405 mm x 1000 mm, 760 mm x 405 mm x 1220 mm, 760 mm x 405 mm x 1525mm, 760 mm x 405 mm x 1650 mm, N.A |
| MISCELENIOUS | Electric fittings | As per Buyer's choice |
| MISCELENIOUS | Number of Windows | 1 no. window, 2 nos. windows, 3 nos. Window, 4 nos. Window, 5 nos. Window |
| MISCELENIOUS | Roof ridge | To be made out from 0.45 mm thick PPGI sheet., N.A |
| MISCELENIOUS | Flashing item (U track, L corner etc) | To be made out with 0.45 mm thick PPGI sheet in require size and shape., N.A, As per Buyerβs choice |
| MISCELENIOUS | Locking / Security | Cabin have to be provision of locking Door and Windows to prevent unwanted intrusion and theft., N.A, Door Locking arrangement from outside with separate handles on both sides of the door. Door fitted with lock and door closure fitted from inside. |
| COLOUR AND FINISH | Colour | White, Green, Blue, Grey, As per Buyer's choice |
| COLOUR AND FINISH | Top coat | Chlorinated rubber paint 50 microns., Bituminous paint., N.A |
| COLOUR AND FINISH | Paint outside | Two coats of synthetic enamel paint to be applied on expose structure and all MS items after installation., Weather texture roller paint, All exterior panels to be white and Blue texture excluding the acrylic / polycarbonate and aluminium frames., As per Buyer's choice, 1 coat primer and 2 coats of enamel exterior paint(colour as per buyer's choice), N.A |
| COLOUR AND FINISH | Inside finish | Internal panels - doors - ceiling - shutter to be white finish (excluding polycarbonate / acrylic glass sheet and aluminium frames on windows), Weather texture roller paint., Wall internal cladding by 50 mm thick glasswood with 6 mm prelaminated plywood with white colour sunmica fixed with aluminium stiffener and rivets, As per Buyer's choice, Inner panelling in all walls and roof provided with Decorative laminated sheet fixed on moisture resistant plywood |
| COLOUR AND FINISH | Logo (if any) | Approved logo of desired size to be painted as per Buyer's requirement., No logo |
| CERTIFICATION | Test reports to be furnished to buyer's on demand | Yes |
| CERTIFICATION | OEM of offered product is ISO 9001:2015 certified | Yes, No |
| CERTIFICATION | OEM of offered product is ISO 14001:2015 certified | Yes, No |
| CERTIFICATION | OEM of offered product is ISO 18001:2007 certified | Yes, No |