Electrocardiography (ECG) Machine (V2)
Chittaranjan Locomotive Works
BARDHAMAN, WEST BENGAL
Bid Publish Date
06-Jun-2026, 12:25 pm
Bid End Date
22-Jun-2026, 12:00 pm
Value
₹1,44,900
Progress
Quantity
1
Bid Type
Two Packet Bid
Public procurement opportunity for Indian Air Force Electrocardiography (ECG) Machine (V2) (Q2). Quantity: 1 issued by. Submission Deadline: 22-06-2026 12: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Electrocardiography (ECG) Machine (V2) (Q2)
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Chittaranjan Locomotive Works
BARDHAMAN, WEST BENGAL
North Eastern Railway
BAREILLY, UTTAR PRADESH
N/a
Government Medical College And Hospital
CHANDIGARH, CHANDIGARH
Indian Air Force
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| PRODUCT INFORMATION | Operating modes of ECG Machine | Automatic, Manual and Rhythm |
| PRODUCT INFORMATION | ECG machine should have ECG lead annotation facility | Yes |
| PRODUCT INFORMATION | Leads which is in ECG machine should be able to acquire simultaneously and interpret them | 12 |
| PRODUCT INFORMATION | Number of channels | 12 Channel |
| PRODUCT INFORMATION | ECG machine should acquire lead ECG for both adult and pediatric patients | Yes |
| PRODUCT INFORMATION | The ECG machine should have facility to show lead fail indication | Yes |
| PRODUCT INFORMATION | The ECG machine should have facility to show lead reversal indication | Yes |
| PRODUCT INFORMATION | Acquisition time for ECG Machine in sec | 10 sec |
| PRODUCT INFORMATION | ECG machine should have frequency filters | Artifact, AC and low and high pass frequency filters |
| PRODUCT INFORMATION | Number of ECGs which can be store in ECG Machine | 151 to 200 |
| PRODUCT INFORMATION | ECG machine should have full screen preview of ECG report for quality assessment checks prior to print | Yes |
| PRODUCT INFORMATION | Type of inbuilt screen | LCD, LED |
| PRODUCT INFORMATION | Size of screen in inches | 5, 10, 12 |
| PRODUCT INFORMATION | Display resolution of ECG machine in pixels | 640 x 480 |
| PRODUCT INFORMATION | ECG machine should have alphanumeric keyboard for patient data entry | Hard keys |
| PRODUCT INFORMATION | Availability of latest interpretation software | Yes, No |
| PRODUCT INFORMATION | System should have the dedicated software to download the ECG form machine in PDF format | Yes |
| PRINTER | Printer Type | Thermal Printer |
| PRINTER | Recorder Paper Size | A4 Size |
| PRINTER | Recorder Speed | 10 mm/sec, 25 mm/sec, 50 mm/sec |
| BATTERY | Provision of Battery | Yes |
| BATTERY | Battery Type | Built in Rechargeable Battery |
| BATTERY | Battery capacity of continuous rhythm recording on single charge (minutes) | 60 |
| BATTERY | Battery capacity | 50 ECG or 1 hour of continous rhythm recording on single charge |
| BATTERY | The individual patient lead should be change without replacing the whole patient cable assembly | Yes |
| ENVIRONNMENTS PARAMETERS | Operating temperature and humidity | Temperature of 10 to 40 degree Celsius and Relative Humidity of 15 to 90% |
| POWER SUPPLY | Power input | 220-240 V AC, 50 Hz fitted with Indian plug |
| ACCESSORIES | Patient Cable | 2 |
| ACCESSORIES | Chest Electrodes Adult (set of Six) | 1, 2 |
| ACCESSORIES | Chest Electrodes Paediatric (set of Six) | 2, Not provided |
| ACCESSORIES | Limb Electrodes | 2 for adults and 2 for paediatric |
| ACCESSORIES | Power cable for charging | Yes |
| ACCESSORIES | Supplied with Clip electrode | Yes |
| CERTIFICATION & REPORTS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATION & REPORTS | Availability of valid drug license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATION & REPORTS | Manufacturing unit certification | ISO:13485 (Latest) |
| CERTIFICATION & REPORTS | Compliance to Safety Standards | IS 13450:Part 2:Sec 25 / IEC 60601-2-25 |
| WARRANTY | Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3, 4, 5 Or higher |
| Miscellaneous Parameters | The Principal Manufacturer must have direct Presence/approved service center In India | Yes |
| Miscellaneous Parameters | Installation and demonstration of equipment and training to be provided after completing supplies before acceptance | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
OEM Authorization Certificate
OEM Annual Turnover
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Chhattisgarh Medical Services Corporation Limited
📍 RAIPUR, CHHATTISGARH
Nuclear Power Corporation Of India Limited
📍 UTTARA KANNADA, KARNATAKA
N/a
📍 MUMBAI, MAHARASHTRA
Indian Air Force
📍 CHANDIGARH, CHANDIGARH
N/a