View Catalog| Category | Specification | Requirement | 
|---|---|---|
| Generic | Measuring Parameter | Potassium (K), Sodium (Na), Chloride (Cl), Ionized calcium (iCa), Calcium (Ca), Lithium (Li) | 
| Generic | Sample Type | Serum, Plasma, Whole Blood, Cerebrospinal Fluid, Urine, Other Biological Body Fluid | 
| Generic | Measuring Method | Ion selective electrode (ISE) | 
| Generic | Minimum Sample Volume | 50 Micro Litre, 60 Micro Litre, 70 Micro Litre, 80 Micro Litre, 90 Micro Litre Or higher | 
| Generic | Rapid Test Speed Capability | More than 60 tests per hour | 
| Generic | Sample Analysis Time | <=30 sec, <=45 sec, <= 60 sec Or higher | 
| Measurement of Sodium | Measuring Range of Na (Blood Sample) | 40-200 mmol/L | 
| Measurement of Sodium | Measuring Range of Na (Urine Sample) | 3-300 mmol/L | 
| Measurement of Sodium | Resolution of Na (in mmol/L) | 0.1 | 
| Measurement of Sodium | Measuring Accuracy of Na (+/-) (In %) | 0.1%, 1%, 2% Or higher | 
| Measurement of Potassium | Measuring Range of K (Blood Sample) | 0.5 - 15 mmol/L | 
| Measurement of Potassium | Measuring Range of K (Urine Sample) | 5-120 mmol/L | 
| Measurement of Potassium | Resolution of K (in mmol/L) | 0.1 | 
| Measurement of Potassium | Measuring Accuracy of K (+/-) (In %) | 0.5%, 1%, 2% Or higher | 
| Measurement of Chlorine | Measuring Range of Cl (Blood Sample) | 50-200 mmol/L | 
| Measurement of Chlorine | Measuring Range of Cl (Urine Sample) | 25-500 mmol/L | 
| Measurement of Chlorine | Resolution of Cl (in mmol/L) | 0.1 | 
| Measurement of Chlorine | Measuring Accuracy of Cl (+/-) (In %) | 0.5%, 1%, 2% Or higher | 
| Measurement of Lithium | Measuring Range Li (Blood Sample) | 0.2 - 5 mmol/L | 
| Measurement of Lithium | Resolution of Li (in mmol/L) | 0.1 | 
| Measurement of Lithium | Measuring Accuracy of Li (+/-) (In %) | 0.5%, 1%, 2% Or higher | 
| Measurement of Calcium | Measuring Range Ca (Blood Sample) | 0.1-5 mmol/L | 
| Measurement of Calcium | Resolution of Ca (in mmol/L) | 0.01 | 
| Measurement of Calcium | Measuring Accuracy of Ca (+/-) (In %) | 0.5%, 1%, 2% Or higher | 
| Measurement of pH | Resolution of pH | 0.01 | 
| Measurement of pH | Measuring Accuracy of pH (+/-) (In %) | 0.5%, 1%, 2%, 5%, NA Or higher | 
| Measurement of Total Carbon Di-Oxide | Resolution of Carbon Di-Oxide (in mmol/L)) | 0.01 | 
| Measurement of Total Carbon Di-Oxide | Measuring Accuracy of TCO2 (+/-) (In %) | 0.5%, 1%, 2%, 5%, NA Or higher | 
| Display | Display Type | LCD | 
| Display | Display Size ( In Inches) | 5, 6, 7, 8, 9, 10 Or higher | 
| Display | Connectivity Interface/Port | RS232 | 
| Display | Features of Display | Data Displayed on Computer through Connected Interface | 
| Auto Sampler | Auto Sampler Provided? | No | 
| Auto Sampler | Number of Positions provided in Auto sampler | 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 Or higher | 
| Software | Suitable Application Software Provided | Yes | 
| Software | Feature for Software | Option to feed Patient Name and Patient ID | 
| UPS Specifications | Suitable Online UPS Provided | No | 
| UPS Specifications | Rating of UPS in KVA | 1, 2, 3, 5 Or higher | 
| UPS Specifications | Minimum Power Backup time ( In Minutes) | 15, 30, 60 Or higher | 
| Printer Specifications | Suitable inbuilt Printer Provided | Yes | 
| Buyer Specific Requirement & Features | Features | Real time reagent level monitoring and alarming systems, Separate electrode for sodium, potassium, calcium, ionized calcium and lithium, Integrated Pack to avoid Wastage Handling, Maintenance free electrodes, Automatic one and two points calibration, User controlled manual calibration option, NA | 
| Buyer Specific Requirement & Features | Accessories | Sample tray, Reagent pack for 1000 tests, Reagent pack for 2000 tests, Reagent pack for 500 tests | 
| Buyer Specific Requirement & Features | Barcode Scanner Provided (To scan the data of reagents/electrodes etc) | Yes (Attachable through R232/USB Interface) | 
| Environmental Condition | Minimum Operating Temperature ( °C) | -5, 0, 5, 10 Or lower | 
| Environmental Condition | Maximum Operating Temperature (°C) | 40, 45, 50 Or higher | 
| Environmental Condition | Operating Humidity (%) | 95.0 | 
| Power Supply / Power Source | Power Source | Mains (230 +/- 10 Volts / 50 Hz AC) | 
| Training | Training Methods | Onsite at the time of Installation | 
| Training | Number of Days for Training | 2 | 
| Warranty & Service | Warranty on Complete Unit | 3 Years Or higher | 
| Warranty & Service | Service/Repair request response time | 24 Hours Or higher | 
| Calibration Certificate | Calibration Certificate issuing authority | OEM Certificate | 
| Test Report | Type of lab which carried out Test of Complete Product to prove the conformity of product as per specification | NABL Accredited Lab | 
AI-Powered Bidder Prediction
Companies most likely to bid
Unlock Bidder Insights
AI predictions on likely bidders
Required Documents
1
Experience Criteria
2
Past Performance
3
Bidder Turnover
4
Certificate (Requested in ATC)
5
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
6
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Download FREE!
Access all tender documents at no cost
    Documents  3  
 GeM-Bidding-8456692.pdf
Main Document
CATALOG-Specification-1
CATALOG Specification
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS
GeM-Bidding-8456692.pdf
Main Document
CATALOG-Specification-1
CATALOG Specification
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS