View Catalog| Category | Specification | Requirement |
|---|---|---|
| FEATURES | Description of the itemuu | Two port vector network analyzers(with spectrum analyser) |
| GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER | Markers | Normal |
| GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER | Trigger | Free run, video, External |
| GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER | Display | TFT Colour display |
| GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER | Interface | USB, LAN |
| GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER | Software for transfer of screen shot/measurement data to PC | Yes |
| SPECTRUM ANALYZER FEATURES | Frequency Range | 9 kHz to 3 GHz |
| SPECTRUM ANALYZER FEATURES | Aging rate of spectrum analyzer frequency: Better than 1x10-6 /Year | Yes |
| SPECTRUM ANALYZER FEATURES | Frequency counter Resolution(minimum) (Hz) | 0.01Hz |
| SPECTRUM ANALYZER FEATURES | Frequency Span | 1kHz to 3GHz |
| SPECTRUM ANALYZER FEATURES | Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz | NA |
| SPECTRUM ANALYZER FEATURES | Spectral purity:Harmonics @ -40dBm level <=60 dBc | NA |
| SPECTRUM ANALYZER FEATURES | Sweep time @span >or= 1 KHz | 2.5mS to 1000S |
| SPECTRUM ANALYZER FEATURES | Sweep time @span = 0 Hz | NA |
| SPECTRUM ANALYZER FEATURES | Resolution Bandwidth (-3dB) | NA |
| SPECTRUM ANALYZER FEATURES | Video Bandwidth | 1 Hz to 3 MHz |
| SPECTRUM ANALYZER FEATURES | Amplitude : Max input level for protection (dBm) | +30 |
| SPECTRUM ANALYZER FEATURES | Amplitude : Max input level for measurement (dBm) | 30 |
| SPECTRUM ANALYZER FEATURES | Amplitude :level measurement uncertainity (dB) | <=1, <=±1 |
| SPECTRUM ANALYZER FEATURES | Average noise level displayed(@300HzRBW,10Hz VBW) | <=-130dBm for 10MHz to 3 GHz & |
| SPECTRUM ANALYZER FEATURES | Average noise level displayed(@100HzRBW,1Hz VBW) | <=-130dBm for 10MHz to 3 GHz & |
| SPECTRUM ANALYZER FEATURES | Average noise level displayed(@300HzRBW,1Hz VBW) | <=-130dBm for 10MHz to 3 GHz & |
| SPECTRUM ANALYZER FEATURES | Measurement features | NA |
| VECTOR NETWORK ANALYZER FEATURES | Frequency Range for 2port vector network analyzer | 2 MHz to 3 GHz |
| VECTOR NETWORK ANALYZER FEATURES | Frequency Resolution (CW ON) (Hz) | 100KHz |
| VECTOR NETWORK ANALYZER FEATURES | Return Loss (dB) | 0.00 to 60 |
| VECTOR NETWORK ANALYZER FEATURES | VSWR (dB) | 1.01 to 10.00 |
| VECTOR NETWORK ANALYZER FEATURES | Cable Loss (dB) | NA |
| VECTOR NETWORK ANALYZER FEATURES | Calibration with Precision calibration components-open, short, load should be included to achieve directivity >35 dB hint: NA for items designated as spectrum analyzers | open, short, load & Through should be included to achieve directivity >40 dB |
| VECTOR NETWORK ANALYZER FEATURES | Abilty to locate Distance-to-fault in Co-axial cables | NA |
| VECTOR NETWORK ANALYZER FEATURES | Phase Range (degree) | NA |
| VECTOR NETWORK ANALYZER FEATURES | Phase Resolution (deg) | NA |
| VECTOR NETWORK ANALYZER FEATURES | RF output port | Yes |
| VECTOR NETWORK ANALYZER FEATURES | Dynamic Range | 60 |
| VECTOR NETWORK ANALYZER FEATURES | Nominal port power output: Hi Power/Lo-Power selectable | NA |
| VECTOR NETWORK ANALYZER FEATURES | Measurement of S11 and S21 and Smith Chart | Yes |
| VECTOR NETWORK ANALYZER FEATURES | Vector Voltmeter for comparision and verification of the phase of the phase-matched cables | NA |
| OPERATING CONDITIONS | Operating Temperature | '5 to 40 degree C & 80% RH @ 40 degree C |
| OPERATING CONDITIONS | Operating Humidity | 80% RH @ 40 degree C |
| POWER REQUIREMENT | Power requirement | 230 +- 10 VAC, 50Hz |
| POWER REQUIREMENT | chemistry of the battery | NA |
| POWER REQUIREMENT | Suitable charger / adaptor provided | NA |
| WARRANTY | Warranty | 1, 2, 3, 4, 5 Or higher |
| CERTIFICATION/TEST REPORT DETAILS | The equipment supplied with calibration certificate | yes |
| CERTIFICATION/TEST REPORT DETAILS | conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:9000/part-3/section-5/1977 latest | no |
| CERTIFICATION/TEST REPORT DETAILS | conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:9000/part-2/section-4/1977 latest | no |
| CERTIFICATION/TEST REPORT DETAILS | conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH | no |
| CERTIFICATION/TEST REPORT DETAILS | Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification | No |
AI-Powered Bidder Prediction
Companies most likely to bid
Unlock Bidder Insights
AI predictions on likely bidders
Required Documents
1
Certificate (Requested in ATC)
2
Additional Doc 1 (Requested in ATC)
3
Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
4
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Download FREE!
Access all tender documents at no cost
Documents 4
GeM-Bidding-8445507.pdf
Main Document
CATALOG-Specification-48-items
CATALOG Specification
Buyer uploaded ATC document
ATC
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS
GeM-Bidding-8445507.pdf
Main Document
CATALOG-Specification-48-items
CATALOG Specification
Buyer uploaded ATC document
ATC
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS