GEM

Contract Bidding Open For Cassette AC 2Tr,Hi wall Split AC 2.0 Tr,Hi wall Split AC 1.5 Tr,Installation of cassette AC,Install in LUCKNOW, UTTAR PRADESH

Posted

04 Oct 2025, 07:21 pm

Deadline

15 Oct 2025, 04:00 pm

EMD

₹8,500

Value

₹9,78,692

Progress

Issue04 Oct 2025, 07:21 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

648

Category

Cassette AC 2Tr

Bid Type

Two Packet Bid

Categories 7

A tender has been published for State Bank Of India (sbi) Cassette AC 2Tr, Hi wall Split AC 2. 0 Tr, Hi wall Split AC 1. 5 Tr, Installation of cassette AC, Installation of Hi wall Split AC, Additional Copper pipe for Cassette AC, Additional Copper pipe for Hi wall split AC, Cable for cassette AC, Cable for Hi wall split AC, Drain pipe 25 mm, Drain pipe 32 mm, Outdoor Stand, Stabiliser 5 KVA 2Tr AC, Stabiliser 4 KVA for 1. 5 or 1 Tr AC, Dismanteling of existing split ACs, Core Cutting in LUCKNOW, UTTAR PRADESH. Quantity: 648 by. Submission Deadline: 15-10-2025 16: 00: 00. Check eligibility and apply.

Bill of Quantities (BOQ) 16 Items

Item # Title Description Quantity Unit Consignee Delivery (Days)
1 Cassette AC 2Tr Supply of ceiling suspended energy efficient 4 way air-flow Cooling type 5 star single phase 2 Tr, Cassette type split air conditioner in recessed manner in false ceiling. Refer technical specification for details. 4 set sbilholuc.buy_con9 30
2 Hi wall Split AC 2.0 Tr Supply of 2.0 Tr hi wall type BEE rated 5 star inverter technology split air conditioner with full function wireless remote and auto restart feature. Refer technical specification for details. 4 set sbilholuc.buy_con9 30
3 Hi wall Split AC 1.5 Tr Supply of 1.5 Tr hi wall type BEE rated 5 star inverter technology split air conditioner with full function wireless remote and auto restart feature. Refer technical specification for details. 2 set sbilholuc.buy_con9 30
4 Installation of cassette AC Installation, testing and commissioning of 4/3/2 TR cassette type air-conditioner with wall cutting/ mounting including making good of damages complete in all respects. 4 set sbilholuc.buy_con9 30
5 Installation of Hi wall Split AC Installation, testing and commissioning of 2/ 1.5/ 1 TR Hi wall type split/window air conditioner/ old AC dismantled from branch with wall cutting/ mounting, stabiliser and making good of damages complete in all respects. For old AC dismentling also to be done. 6 set sbilholuc.buy_con9 30
6 Additional Copper pipe for Cassette AC Supply, installation, testing and commissioning of insulated copper refrigerant piping set (suction and discharge) duly insulated by nitrile rubber for 4/2 TR cassette AC. Size (thickness and dia) of both Copper pipe. Refer technical specification for details. 110 mtr sbilholuc.buy_con9 30
7 Additional Copper pipe for Hi wall split AC Supply, installation, testing and commissioning of insulated copper refrigerant piping set (suction and discharge) duly insulated by nitrile rubber for 2/ 1.5/ 1 TR hi wall split AC. Size (thickness and diameter) of both Copper pipes. Refer technical specification for details. 80 mtr sbilholuc.buy_con9 30
8 Cable for cassette AC Supply, installation, testing and commissioning of inter connecting wiring/ cabling between indoor and outdoor of Cassette type split AC (power supply will be made available at the outdoor unit, please quote accordingly). 120 mtr sbilholuc.buy_con9 30
9 Cable for Hi wall split AC Supply, installation, testing and commissioning of inter connecting wiring/ cabling between indoor and outdoor of hi wall split AC (power supply will be made available at the outdoor unit, please quote accordingly). 90 mtr sbilholuc.buy_con9 30
10 Drain pipe 25 mm Supply, installation, testing and commissioning of PVC 25 mm water pipe with accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. 80 mtr sbilholuc.buy_con9 30
11 Drain pipe 32 mm Supply, installation, testing and commissioning of PVC 32 mm water pipe with accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. 60 mtr sbilholuc.buy_con9 30
12 Outdoor Stand Supply and installation of robust MS angle, MS flat fabricated floor/ wall mounting stand suitable for outdoor units. Refer technical specification for details. 10 nos sbilholuc.buy_con9 30
13 Stabiliser 5 KVA 2Tr AC Supply of 5 KVA, wall mounted hi lo cut off stabiliser with TDR, voltage range 140-280V, complete in all respects. Refer technical specification for details. 8 set sbilholuc.buy_con9 30
14 Stabiliser 4 KVA for 1.5 or 1 Tr AC Supply of 4 KVA, wall mounted hi lo cut off stabiliser with TDR, voltage range 140-280V, complete in all respects. Refer technical specification for details. 2 set sbilholuc.buy_con9 30
15 Dismanteling of existing split ACs Dismanteling of existing split ACs 8 set sbilholuc.buy_con9 30
16 Core Cutting Core cutting/ wall chiseling upto 75mm width and 50 mm depth for concealing the copper pipe, drain pipe and conduit either on wall or under floor including making good of damages with plaster, putti and paint. 60 mtr sbilholuc.buy_con9 30

AI-Powered Bidder Prediction

Companies most likely to bid

Unlock Bidder Insights

AI predictions on likely bidders

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

Additional Doc 1 (Requested in ATC)

7

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer