GEM

Government Tender Published for Electrolyte Analyzers (V2) in JAMMU, JAMMU & KASHMIR

Posted

16 Oct 2025, 03:52 pm

Deadline

07 Nov 2025, 12:00 pm

Latest Corrigendum Available

Progress

Issue16 Oct 2025, 03:52 pm
Corrigendum31 Oct 2025
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 1

Public procurement opportunity for Employees State Insurance Corporation (esic) Electrolyte Analyzers (V2) (Q2) in JAMMU, JAMMU & KASHMIR. Quantity: 1 issued by. Submission Deadline: 07-11-2025 12: 00: 00. View full details and respond.

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Generic Measuring Parameter Chloride (Cl), Ionized calcium (iCa), Potassium (K), Sodium (Na)
Generic Sample Type Serum, Plasma, Whole Blood, Cerebrospinal Fluid, Urine, Other Biological Body Fluid
Generic Measuring Method Ion selective electrode (ISE)
Generic Minimum Sample Volume 50 Micro Litre, 60 Micro Litre, 70 Micro Litre, 80 Micro Litre, 90 Micro Litre Or higher
Generic Rapid Test Speed Capability More than 50 tests per hour
Generic Sample Analysis Time <=30 sec, <=45 sec, <= 60 sec Or higher
Measurement of Sodium Measuring Range of Na (Blood Sample) 20-200 mmol/L
Measurement of Sodium Measuring Range of Na (Urine Sample) 3-300 mmol/L
Measurement of Sodium Resolution of Na (in mmol/L) 0.1
Measurement of Sodium Measuring Accuracy of Na (+/-) (In %) 0.1% Or higher
Measurement of Potassium Measuring Range of K (Blood Sample) 0.5 - 15 mmol/L
Measurement of Potassium Measuring Range of K (Urine Sample) 5-120 mmol/L
Measurement of Potassium Resolution of K (in mmol/L) 0.1
Measurement of Potassium Measuring Accuracy of K (+/-) (In %) 0.5% Or higher
Measurement of Chlorine Measuring Range of Cl (Blood Sample) 50-200 mmol/L
Measurement of Chlorine Measuring Range of Cl (Urine Sample) 25-500 mmol/L
Measurement of Chlorine Resolution of Cl (in mmol/L) 0.1
Measurement of Chlorine Measuring Accuracy of Cl (+/-) (In %) 0.5% Or higher
Measurement of Lithium Measuring Range Li (Blood Sample) NA (Lithium Measurement Not Offered)
Measurement of Lithium Resolution of Li (in mmol/L) 0.1
Measurement of Lithium Measuring Accuracy of Li (+/-) (In %) 0.5% Or higher
Measurement of Calcium Measuring Range Ca (Blood Sample) 0.1-5 mmol/L
Measurement of Calcium Resolution of Ca (in mmol/L) 0.01
Measurement of Calcium Measuring Accuracy of Ca (+/-) (In %) 0.5% Or higher
Measurement of pH Resolution of pH 0.01
Measurement of pH Measuring Accuracy of pH (+/-) (In %) 0.5% Or higher
Measurement of Total Carbon Di-Oxide Measuring Range of TCO2 (Blood Sample) NA (Carbon Di-Oxide Measurement Not Offered)
Measurement of Total Carbon Di-Oxide Resolution of Carbon Di-Oxide (in mmol/L)) 0.01
Measurement of Total Carbon Di-Oxide Measuring Accuracy of TCO2 (+/-) (In %) 0.5%, 1%, 2%, 5%, NA Or higher
Display Display Type Touch LCD/LED
Display Display Size ( In Inches) 8, 9, 10 Or higher
Display Connectivity Interface/Port RS232, USB
Display Features of Display Data Displayed on Computer through Connected Interface, NA
Auto Sampler Auto Sampler Provided? No
Software Suitable Application Software Provided Yes
Software Feature for Software Option to feed Patient Name and Patient ID
UPS Specifications Suitable Online UPS Provided Yes
UPS Specifications Rating of UPS in KVA 3, 5 Or higher
UPS Specifications Minimum Power Backup time ( In Minutes) 30, 60 Or higher
Printer Specifications Suitable inbuilt Printer Provided Yes
Buyer Specific Requirement & Features Features Real time reagent level monitoring and alarming systems, Separate electrode for sodium, potassium, calcium, ionized calcium and lithium, Integrated Pack to avoid Wastage Handling, Maintenance free electrodes, Automatic one and two points calibration, User controlled manual calibration option, NA
Buyer Specific Requirement & Features Accessories Reagent pack for 500 tests
Buyer Specific Requirement & Features Barcode Scanner Provided (To scan the data of reagents/electrodes etc) No
Environmental Condition Minimum Operating Temperature ( °C) -5, 0, 5, 10 Or lower
Environmental Condition Maximum Operating Temperature (°C) 40, 45, 50 Or higher
Environmental Condition Operating Humidity (%) 85.0
Environmental Condition Ingress Protection NA
Power Supply / Power Source Power Source Mains (230 +/- 10 Volts / 50 Hz AC)
Training Training Methods Onsite at the time of Installation
Training Number of Days for Training 2
Warranty & Service Warranty on Complete Unit 3 Years Or higher
Warranty & Service Service/Repair request response time 24 Hours Or higher
Calibration Certificate Calibration Certificate issuing authority OEM Certificate
Test Report Type of lab which carried out Test of Complete Product to prove the conformity of product as per specification OEM, Govt Lab, NABL Accredited Lab, ILAC Accredited Lab

AI-Powered Bidder Prediction

Companies most likely to bid

Unlock Bidder Insights

AI predictions on likely bidders

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria

7

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Corrigendum Updates

1 Update
#1

Update

31 Oct 2025

Extended Deadline

07 Nov 2025, 12:00 pm

Opening Date

07 Nov 2025, 12:30 pm