View Catalog| Category | Specification | Requirement |
|---|---|---|
| Types of Probes & Features | Convex Probe | 2.5 to 5 MHz (Β±2), Not Provided |
| Types of Probes & Features | Microconvex probe | 4 to 8 MHz (Β±2), Not Provided |
| Types of Probes & Features | Linear array probe | 5 to 10 MHz (Β±2), 3 to 12 MHz (Β±2), 6 to 15 MHz (Β±2), 6 to 18 MHz (Β±2), Not provided |
| Types of Probes & Features | TVS Probe | 4 to 9 MHz (Β±2), Not Provided |
| Types of Probes & Features | Cardiac Probe | 1 to 5 MHz (Β±2), 5 to 9 MHz (Β±2), Not Provided |
| Types of Probes & Features | Hockey Stick Probe | 6 to 17 MHz (Β±2), 6 to 13 MHz (Β±2), 8 to 20 MHz (Β±2), Not Provided |
| Types of Probes & Features | Volume Convex Probe | 2.5 to 5 MHz (Β±2), Not Provided |
| Types of Probes & Features | Volume Linear Probe | 3 to 12 MHz (Β±2), 6 to 15 MHz (Β±2), 6 to 18 MHz (Β±2), 5 to 10 MHz (Β±2), Not Provided |
| Types of Probes & Features | Volume TVS Probe | 4 to 9 MHz (Β±2), Not Provided |
| Types of Probes & Features | Endorectal Probe | 5 to 9 MHz (Β±2), Not Provided |
| Types of Probes & Features | E-Breast Elastography technique | No |
| Types of Probes & Features | E-Thyroid Elastography technique | No |
| Types of Probes & Features | Liver Elastography technique | No |
| Types of Probes & Features | Gel Warmer | Yes |
| Types of Probes & Features | Dedicated 3-D/4-D | Yes |
| Scan Modes | Contrast harmonic imaging with angio mode | No |
| Scan Modes | Provision of Harmonic imaging in Linear Probes | Yes |
| Scan Modes | Color Doppler imaging (CDI) | Yes |
| Scan Modes | Color Doppler 3-D/4-D option | No |
| Scan Modes | Power Doppler imaging (PDI) | Yes |
| Scan Modes | Power Doppler 3-D/4-D option | No |
| Scan Modes | Continuous wave | Yes |
| Scan Modes | Triplex mode | Yes |
| Scan Modes | Tissue Doppler imaging | Yes |
| Scan Modes | Contrast-enhanced ultrasoundΒ (CEUS) option | No |
| Scan Modes | Tissue synchronization, tissue velocity | No |
| Scan Modes | Probes supplied shall be in latest generation bandwidth | Yes |
| Scan Modes | Provision for higher sensitivity for low frequency doppler in all probes | Yes |
| Scan Modes | Number of channels in color doppler system | 4000000 or more (if channels are being designated as digital channels) |
| Scan Modes | Live 3 D imaging in color doppler system | Yes |
| Scan Modes | Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval | Yes |
| Scan Modes | Provision of Tissue Colorization (B-Colour) for improved contrast resolution | Yes |
| Scan Modes | Cine Loop Features | Yes |
| Scan Modes | Frame grabber facility for post analysis | No |
| Scan Modes | Number of transducer/probe ports | 4 or More |
| Scan Modes | System should be capable of generating real time live 3- D images | Yes |
| Scan Modes | Contrast agent imaging | Yes |
| Image Display and Processing | DICOM 3 Compliant | Yes |
| Image Display and Processing | Automated B-mode (2-D) image | Yes |
| Image Display and Processing | Automated CDI(Color Doppler Imaging) image optimization | Yes |
| Image Display and Processing | Automated PW Doppler image optimization | Yes |
| Image Display and Processing | Touch Screen | Yes |
| Image Display and Processing | Monitor display size (inch) | 21 or more Or higher |
| Image Display and Processing | Split screen | Twin View |
| Image Display and Processing | Single/dual monitors | Dual (image display and touch panel) |
| Image Display and Processing | Max number frames | >=1000 |
| Image Display and Processing | Digital storage hard drive, GB | >=500 |
| Image Display and Processing | DVD/CD Writer/ USB | Yes |
| Image Display and Processing | Type of processor (in PC) | i7 or latest |
| Image Display and Processing | RAM capacity of PC in GB (hint: In case PC not provided put zero) | β₯ 4 |
| Image Display and Processing | Processor speed in GHz (PC) | β₯ 3 |
| Image Display and Processing | Frame Grabber incorporated(PC) | Yes |
| Image Display and Processing | Connectivity between USG and PC | Yes |
| Image Display and Processing | PC with all software inclusive interfaced with USG machine | Yes |
| Image Display and Processing | Laser Color printer provided | Yes |
| Image Display and Processing | Inkjet/Thermal printer provided | Yes |
| Image Display and Processing | CD/DVD/USB Produced should be playable on any system | Yes |
| Image Display and Processing | Glossy Colour Print Paper supplied | 500 sheets |
| Image Display and Processing | Dicom Interfacability Dicom to PACS | Yes |
| Image Display and Processing | Interfacability Dicom to RIS | Yes |
| Power Requirements | Resettable over current breaker shall be fitted for protection | Yes |
| Power Requirements | Power backup | UPS |
| Power Requirements | Back up time in minutes (minimum) | 30.0 |
| Power Requirements | Suitable Servo Controlled Stabilizer / CVT should be provided | Yes, No |
| Warranty and Maintenance | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5 Or higher |
AI-Powered Bidder Prediction
Companies most likely to bid
Unlock Bidder Insights
AI predictions on likely bidders
Required Documents
1
Experience Criteria
2
Past Performance
3
Bidder Turnover
4
OEM Authorization Certificate
5
OEM Annual Turnover
6
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
7
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Download FREE!
Access all tender documents at no cost
Documents 3
GeM-Bidding-8488188.pdf
Main Document
CATALOG-Specification-1
CATALOG Specification
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS
GeM-Bidding-8488188.pdf
Main Document
CATALOG-Specification-1
CATALOG Specification
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS