Tender Overview
The
Progress
Quantity
1
Bid Type
Two Packet Bid
The
| Category | Specification | Requirement | 
|---|---|---|
| Coin / Card Acceptor / Quantity of Dispensing Water | Number of Dispensing points | 2, 3, 4, 5, 6 Or higher | 
| Coin / Card Acceptor / Quantity of Dispensing Water | Water Dispensing using coin acceptor | Yes | 
| Coin / Card Acceptor / Quantity of Dispensing Water | Coins accepted for payment | Re.1, Rs. 2, Rs. 5, Rs.10, Rs. 20 | 
| Coin / Card Acceptor / Quantity of Dispensing Water | Water Dispensing using RFID/NFC card | Yes | 
| Coin / Card Acceptor / Quantity of Dispensing Water | Mobile Wallet accepted for payment | No | 
| CAPACITY / TYPE / WATER SOURCE / OUTLET WATER QUALITY | Purification Capacity of Water ATM (LPH) | 250, 300, 500, 1000, 2000 Or higher | 
| CAPACITY / TYPE / WATER SOURCE / OUTLET WATER QUALITY | Type of Operation | Semi-Automatic, Automatic with Multi-Processor Integrated Control System and remotely conrolled web based Server system Or higher | 
| CAPACITY / TYPE / WATER SOURCE / OUTLET WATER QUALITY | Water Source | Borewell Water | 
| TECHNOLOGY | Technology | Reverse Osmosis (RO) | 
| TECHNOLOGY | Anti scalant dosing pump | Yes | 
| TECHNOLOGY | pH Correction Dosing Pump | No | 
| CONSTRUCTIONAL | Raw water Storage capacity (Indicate '0' for direct connection to continuous Tap Water source) | 0, 100, 200, 500, 1000, 2000, 3000, 5000, 8000, 10000 Or higher | 
| CONSTRUCTIONAL | Raw water Storage Tank Material of Construction | HDPE | 
| CONSTRUCTIONAL | Location of the Raw Water Storage Tank | Inside the ATM Enclosure | 
| CONSTRUCTIONAL | Treated water Storage capacity | 201-250, 251-300, 301-350, 351-400, 401-500, 501-600, 601-700, 701-800, 801-1000 Or higher | 
| CONSTRUCTIONAL | Treated water Storage Tank Material of Construction | Stainless Steel 316 Gr, Stainless Steel 304 Gr, HDPE Or higher | 
| CONSTRUCTIONAL | Equipped with an in-built chiller unit for providing continuous cold water of temperature around 15 degree Celcius | Yes | 
| CONSTRUCTIONAL | In-built Chiller Tank Capacity (Liter) | 201-250, 251-300, 301-350, 351-400, 401-500, 501-600, 601-700, 701-800, 801-1000 Or higher | 
| CONSTRUCTIONAL | Chiller Tank Material of Construction | Stainless Steel 316 Gr, Stainless Steel 304 Gr Or higher | 
| CONSTRUCTIONAL | Number of Filtration steps | 7 | 
| CONSTRUCTIONAL | Provided with suitable vending place for filling container of 20 liters capacity | Yes | 
| DISPLAY | Display of water purity parameters | Yes, No | 
| DISPLAY | Display Type | LED, LCD, TFT, NA Or higher | 
| DISPLAY | Backlit Display | Yes, No | 
| DISPLAY | Touch Screen Display | Yes, No | 
| DISPLAY | Display Size (Characters x Lines) | 4 x 2 (4 Ch x 2 lines), 8 x 2 (8 Ch x 2 lines), 16 x 2 (16 Ch x 2 lines), 20 x 2 (20 Ch x 2 lines), 7" Tablet, NA | 
| DISPLAY | Display of oulet water TDS level | Yes, No | 
| DISPLAY | Display of outlet water pH level | Yes, No | 
| DISPLAY | Display of outlet water Temperature | Yes, No | 
| Inlet / Feed Pump to feed water from raw water storage tank to filter | Inlet / Feed Pump Type | Horizontal Centrifugal | 
| Inlet / Feed Pump to feed water from raw water storage tank to filter | Number of Inlet / Feed Pumps | 1 | 
| Multi Media Filter Vessels for First stage filtration for suspended particles | Material Of Construction for Multi Media Filter Vessels | FRP, Steel Or higher | 
| Multi Media Filter Vessels for First stage filtration for suspended particles | Number of Multi Media Filter Vessels | 2, 1 Or higher | 
| Multi-Port Valve to control filtration and backwash for media filter having sand & carbon | Type of Multi-Port Valve | Manual | 
| Multi-Port Valve to control filtration and backwash for media filter having sand & carbon | Multi-Port Valve Material of Construction | PP | 
| Multi-Port Valve to control filtration and backwash for media filter having sand & carbon | Number of Multi-Port Valves | 1 | 
| Anti scalent Dosing Pump to inhibit scaling of hardness salt and silica on RO Membranes, doze pH and Cl as per water quality | Type of Anti scalent Dosing Pump | NA | 
| Anti scalent Dosing Pump to inhibit scaling of hardness salt and silica on RO Membranes, doze pH and Cl as per water quality | Material Of Construction for Anti scalent Dosing Pump | NA | 
| Anti scalent Dosing Pump to inhibit scaling of hardness salt and silica on RO Membranes, doze pH and Cl as per water quality | Number of Anti scalent Dosing Pumps | NA | 
| pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals | Type of pH Correction Pump | NA | 
| pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals | Material Of Construction for pH Correction Dosing Pump | NA | 
| pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals | Number of pH Correction Dosing Pumps | NA | 
| pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals | Dosing Tank Material of Construction | NA | 
| High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes | Type of High Pressure Pump | Vertical Centrifugal Pump | 
| High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes | Material Of Construction for High Pressure Pump | SS | 
| High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes | Number of High Pressure Pumps | 1, 2, 3 Or higher | 
| High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes | Low pressure switch for Protection of HP pump from burn-out | Yes | 
| RO Pressure Vessel | Type of RO Pressure Vessel | Membrane housing mounted on skid - End port type | 
| RO Pressure Vessel | Material Of Construction for RO Pressure Vessel | FRP | 
| RO Pressure Vessel | Number of RO Pressure Vessels | 1, 2, 3, 4 Or higher | 
| Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms | Material Of Construction for UV System | SS | 
| Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms | Number of UV Systems | 1, 2 Or higher | 
| Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms | Number of UV Lights | 1, 2, 3, 4, 5, 6 Or higher | 
| Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms | Total UV Power | 12 Watts | 
| CIP (Clean-In-Place)Tank to mix / Dilute chemicals for membrane cleaning and permeate back wash | CIP Tank | No | 
| CIP (Clean-In-Place)Tank to mix / Dilute chemicals for membrane cleaning and permeate back wash | CIP Tank Material of Construction | NA | 
| CIP (Clean-In-Place)Tank to mix / Dilute chemicals for membrane cleaning and permeate back wash | Number of CIP Tanks | NA Or higher | 
| Power Source | Power Source | AC Power Supply | 
| Power Source | Power Supply | 230 ±10 V AC | 
| Power Source | Battery back-up time (Hours) | 6, 8, 10, 12, 14, 16, 18, 20, 22, 24 Or higher | 
| Water ATM - Enclosure | Structure | Rigid structure made of MS frame, Rigid structure made of SS frame(3),, Rigid structure made of G.I. frame Or higher | 
| Water ATM - Enclosure | Thickness of the frame of structure (mm) | 2.5, 2 Or higher | 
| Water ATM - Enclosure | Material of Construction of Side Panels of Water ATM | Stainless Steel Sheet Or higher | 
| Water ATM - Enclosure | Side Panel Sheet Thickness (mm) | 0.6, 0.8, 1, 1.2 Or higher | 
| Water ATM - Enclosure | PUF insulation of Side Panels of Water ATM | With, Without Or higher | 
| Water ATM - Enclosure | PUF insulation of the door of Water ATM | With, Without Or higher | 
| Water ATM - Enclosure | Provision for in-built litter space | No | 
| Water ATM - Enclosure | Covered area of treatment plant enclosure (Square Foot) | 2-5, 5.1-10, 10.1-15, 15.1-20, 20.1-30, 30.1-40, 40.1-50, 50.1-60, 60.1-70, 70.1-80, 80.1-90, 90.1-100, 100.1-110, 110.1-120 Or higher | 
| Water ATM - Enclosure | Shape of the Water ATM housing | Cubical | 
| Water ATM - Enclosure | Top Canopy of the Water ATM housing | Flat | 
| Water ATM - Enclosure | Headroom for the Water ATM enclosure (Foot) | 7.1-8.0, 8.1-9.0, 9.1-10.0 Or higher | 
| Water ATM - Enclosure | Floor area around the Water ATM enclosure covered with anti-skid tiles | Yes | 
| Water ATM - Enclosure | Water ATM enclosure protected with enclosed MS grill / mesh | Yes | 
| Installation & Commissioning / Warranty | Trial Run and Training provided (inclusive in the Scope of Supply) (Days) | 5, 10 Or higher | 
| Installation & Commissioning / Warranty | Warranty for storage Tanks (Year) | 1, 2, 3, 4, 5 Or higher | 
| Installation & Commissioning / Warranty | Warranty for electrical motors (Year) | 1, 2, 3 Or higher | 
| Installation & Commissioning / Warranty | Warranty for the filters (Year) | 1, 2, 3 Or higher | 
| Installation & Commissioning / Warranty | Warranty for the system (Year) | 1, 2, 3 Or higher | 
| Test Reports | Availability of Test Report from Central Govt /NABL/ILAC accredited lab to prove confirmity to specification | Yes | 
| Test Reports | All the test reports and certificates shall furnish by the supplier to the buyer/consignee on demand | Yes | 
Companies most likely to bid
AI predictions on likely bidders
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Access all tender documents at no cost
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS