GEM

Indian Army Structural Design & Drawings Tender Hyderabad Telangana 2025 IS 456 IS 875 STAAD PRO

Posted

24 Oct 2025, 05:42 pm

Deadline

03 Nov 2025, 07:00 pm

Value

₹5,90,000

Progress

Issue24 Oct 2025, 05:42 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Key Highlights

  • Specific brand/OEM requirements: none specified beyond software tools STAAD PRO V8i and STAAD Foundation Advanced
  • Technical certifications/standards: IS 456-2000, IS 1983-2002, IS 875, IS 13920; IIT/NIT vetting
  • Special clauses: Vetting of structural drawings by IIT/NIT; design notes must indicate adopted parameters
  • Eligibility criteria: consultancy experience in RCC structure design, IS code compliance, software capability
  • Warranty/AMC: not specified
  • Penalties/Performance bonds: not specified
  • Delivery/Installation: not applicable; design and drawings delivery only
  • Unique conditions: soil investigation-based foundation design; dual designer verification

Categories 4

Tender Overview

Indian Army invites proposals for consultancy services to prepare complete structural designs and drawings, and vetting by IIT/NIT for simulator rooms at Arty Centre, Hyderabad, under GE Golconda. Project scope covers an RCC framed structure of approximately 45.75m x 9.15m with 6m clear height, including foundation, plinth beams, lintels, floor/roof beams, slabs, stairs, and ramp. Deliverables include signed designs, vetted drawings, and soft copies in AutoCAD and PDF formats, plus an accompanying BOQ per SSR 2020 for MES & Market rates. Design must be produced by one designer and verified by another, with documentation of notes and design parameters. Estimated project value is ₹590,000. The work requires adherence to specified IS codes and a comprehensive design folder in STAAD Pro V8i and STAAD Foundation Advanced, along with soil- investigation-driven foundation design. Clarity on missing details will be provided by the Engineer-in-Charge. Final vetting will be conducted by IIT/NIT. The tender emphasizes strict coding for software and structural standards, ensuring traceability of design decisions and professional vetting across multiple stages.

Key Specifications

  • Project scope: consultancy for simulator room with stand-by power arrangement

  • Room dimensions: 45.75m x 9.15m, 6m clear height

  • Software: STAAD PRO V8i, STAAD Foundation Advanced

  • Structure: RCC framed; includes foundation, plinth beams, lintels, slabs, stairs, ramp

  • Documentation: AutoCAD format, PDF, and BOQ per SSR 2020

Terms & Conditions

  • 25% quantity/duration variation allowed at contract issue

  • Vet by IIT/NIT; engineer-in-charge clarifications

  • IS code compliance and soil-investigation-based foundation design

Important Clauses

Payment Terms

Not specified in data; expect standard government payment on submission and acceptance

Delivery Schedule

Delivery of signed designs and drawings as per Engineer-in-Charge instructions; exact timeline not provided

Penalties/Liquidated Damages

Not specified in data; typical contracts include LD for delays, but exact rates not disclosed

Bidder Eligibility

  • Experience in structural consultancy for RCC framed buildings

  • Proficiency in STAAD PRO V8i and STAAD Foundation Advanced

  • Compliance with IS codes and environmental/safety norms

AI-Powered Bidder Prediction

Companies most likely to bid

Unlock Bidder Insights

AI predictions on likely bidders

Required Documents

1

GST registration certificate

2

Permanent Account Number (PAN) card

3

Experience certificates for similar consultancy in RCC structures

4

Financial statements or proof of financial stability

5

EMD/Security deposit documents (if applicable)

6

Technical bid documents demonstrating STAAD Pro proficiency

7

OEM authorizations or design software licenses (if required)

8

Engineer-in-Charge clearance notes or project approach statement

Frequently Asked Questions

How to bid for the IIT/NIT vetted RCC design tender in Hyderabad?

Bidders must demonstrate RCC design experience, provide STAAD Pro proficiency, and submit technical bid with AutoCAD drawings, PDF copies, and BOQ per SSR 2020. Include IS code compliance (IS 456, 875, 13920) and soil-investigation-based foundation design notes.

What documents are required for the Hyderabad simulator room project bid?

Submit GST, PAN, company financials, experience certificates for similar RCC projects, technical bid, engineering staff credentials, OEM authorizations if applicable, and software license proof for STAAD PRO V8i and STAAD Fdn Advanced.

What standards must the structural drawings adhere to for this tender?

Drawings must follow IS 456-2000, IS 1983-2002, IS 875, IS 13920, with notes clearly stating adopted design parameters; vetting by IIT/NIT is mandatory.

When is the procurement opportunity for simulator rooms in Hyderabad opening?

The tender requires consultancy for Arty Centre Hyderabad, GE Golconda; while start date not published, bidders should ensure readiness of AutoCAD, PDF deliverables, and BOQ per SSR 2020 for MES & Market rates.

How is the project quantity variation handled in this tender?

The buyer may increase or decrease contract quantity or duration up to 25% at contract issue and subsequently; bidders must accept revised quantities or durations as per ATC terms.

What is the expected deliverable format for the structural designs?

Deliverables include fully signed RCC design drawings on tracing paper, soft copies in AutoCAD format, PDFs, and an analysis folder in STAAD Pro V8i/STAAD Fdn Advanced.

What is the role of IIT/NIT in this Hyderabad project?

IIT/NIT will vet and proof-check the structural designs and drawings for simulator rooms; bidder should anticipate design clarifications from the Engineer-in-Charge during vetting.