Bharuch District Panchayat has released a public tender for High Mast Lighting Tower for large area with LED Flood Lighting System (Q3) in BHARUCH, GUJARAT. Quantity: 2. Submission Deadline: 07-11-2025 13: 00: 00. Download documents and apply online.
   
Categories
 2  
     
Technical Specifications
 1 Item  
 Item #1 Details
View Catalog| Category | Specification | Requirement | 
|---|---|---|
| GENERIC | Height of High Mast Tower (in Meters) | 16 | 
| GENERIC | Installation and commissioning (Installation and commissioning work at multiple locations shall follow as per the guidelines of State/Central Govt rules and regulations as applicable) | Yes. Including Civil work at site | 
| GENERIC | Onsite warranty (in Years) | 2 | 
| High mast System | No of sections | 2 | 
| High mast System | Effective length of each section (in m) | 8.5 | 
| High mast System | Material construction: The mast shall be manufactured using special steel plates, conforming to | 355 gradeasper BSEN10 025 | 
| High mast System | Bottom diameter (in mm) - Minimum | 540 | 
| High mast System | Plate thickness for Middle (in mm) - Minimum | 4 | 
| High mast System | Plate thickness for Bottom (in mm) - Minimum | 5 | 
| High mast System | No of longitudinal welds / section (in Nos) | 2 | 
| High mast System | Diameter of base plate (in mm) - Minimum | 740 | 
| High mast System | Thickness of base plate (in mm) - Minimum | 25 | 
| Wind Load | Maximum Wind load | 50 m/sec | 
| Door Opening | Size of opening and closing door at base compartment of high mast (in mm) - Minimum | 1200 x 250 | 
| Junction Box | Ingress protection for Junction Box i.e. IP Class (as per IS/IEC:60529:2001 latest) Test Report from Central Government lab/NABL/ILAC accrediated lab and report shall furnish to buyer on demand | IP 65 | 
| Junction Box | No of core | 3 | 
| Junction Box | Cable category | FR-LSH | 
| Junction Box | Size of cable (in Sq mm) | 2.5 | 
| Junction Box | Conductor material shall be | Copper | 
| Winch | The winch shall have provision for manual operation in case of failure of the motor | Yes | 
| Stainless Steel Wire Rope | The breaking load of each rope shall be at full load as per the relevant standard | >/=2400 Kg | 
| Electrical System, Cable and Cable Connections | No. of cores | 3 | 
| Electrical System, Cable and Cable Connections | Cable shall be | Unarmoured | 
| Electrical System, Cable and Cable Connections | Conudctor material shall be | Aluminium | 
| Electrical System, Cable and Cable Connections | Cable Category | 1 | 
| Electrical System, Cable and Cable Connections | Incoming power cable from feeder panel to base compartment of mast and cable shall conforming to | IS:7098 (Part 1):1988 latest | 
| Feeder pillar Panel | Feeder pillar panel for each mast | Yes | 
| Feeder pillar Panel | Feeder panel shall be suitable for | 415 V, 3 phase, 4 wire, 50 Hz, AC | 
| Feeder pillar Panel | The control panels shall be | Stand mounted | 
| Feeder pillar Panel | Ingress protection for feeder pillar panel i.e IP Class (as per IS/IEC:60529:2001 latest).Test Report shall furnish from Central Government lab/NABL/ILAC accrediated lab to buyer on demand | IP 65 | 
| Feeder pillar Panel | It shall be fabricated out of | No without feeder pillar panel | 
| Feeder pillar Panel | Thickness of sheet (in mm) | No without feeder pillar panel | 
| Feeder pillar Panel | The panels shall be given pre-treatment and powder coated and color shall be | Grey | 
| Feeder pillar Panel | The stand shall be painted in | Black color | 
| Feeder pillar Panel | Cable entry shall be at the | Bottom | 
| Feeder pillar Panel | The panels shall have | knock outs of the required cable | 
| Feeder pillar Panel | Laminated circuit diagram shall be pasted | No without feeder pillar panel | 
| Feeder pillar Panel | Feeder pillar shall have pad locking arrangement | Yes | 
| Feeder pillar Panel | Earth terminal | 12 mm dia. Bolts | 
| Feeder pillar Panel | Panel shall have a sloping cover to avoid accumulation of dust | Yes | 
| Feeder pillar Panel | Panel shall be provided with incoming & outgoing MCCB / MCB of appropriate rating and in desired quantity depending on total no of circuits in use | yes | 
| Feeder pillar Panel | Timer for automatic ON & OFF of lights with pilot lamps shall be provided | Yes | 
| Feeder pillar Panel | Bus bars material | Yes. Copper | 
| Feeder pillar Panel | No of Cores | 3 | 
| Feeder pillar Panel | Size of cable (in Sq.mm) | 2.5 | 
| Feeder pillar Panel | Cable Shall be | Unarmoured | 
| Feeder pillar Panel | The conductor material shall be | Aluminium | 
| Feeder pillar Panel | cable category | C1 | 
| LED FLOOD LIGHT LUMINAIRE | No. of Luminaires for each high mast lighting tower (in Nos) | 6 | 
| LED FLOOD LIGHT LUMINAIRE | LED Rating/System Wattage/Rated Power for each luminaire | 100W | 
| LED FLOOD LIGHT LUMINAIRE | Luminaire System Efficacy (Lumen/watt) | >/= 100 Lm/Watt | 
| LED FLOOD LIGHT LUMINAIRE | Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest | IP65 | 
| LED FLOOD LIGHT LUMINAIRE | Mounting brackets (included) | Adjustable | 
| LED FLOOD LIGHT LUMINAIRE | Input operating Voltage range and frequency | 90 to 300 Volts AC at 50Hz+/-2Hz | 
| LED FLOOD LIGHT LUMINAIRE | Rated voltage | 230 V AC 50 Hz | 
| LED FLOOD LIGHT LUMINAIRE | Colour temperature | 6000K (+/- 500K) | 
| LED FLOOD LIGHT LUMINAIRE | Optic lense material (UV stabilised) (Write NA for without optic lense supply) | Poly carbonate lense | 
| LED FLOOD LIGHT LUMINAIRE | Operating temperature range | -20 deg C to +50 deg C | 
| LED FLOOD LIGHT LUMINAIRE | The luminaire shall be protected against surges and transients( Internal) | >/=5KV | 
| LED FLOOD LIGHT LUMINAIRE | Number of electronic control gear per luminaire (power supplies) | 2 Nos. | 
| LED FLOOD LIGHT LUMINAIRE | Length of ISI marked three core wire (shall be provided along with supply of material) | 50 cm | 
AI-Powered Bidder Prediction
Companies most likely to bid
Unlock Bidder Insights
AI predictions on likely bidders
Required Documents
1
Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
2
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Download FREE!
Access all tender documents at no cost
    Documents  4  
 GeM-Bidding-8517919.pdf
Main Document
CATALOG-Specification-1
CATALOG Specification
Buyer uploaded ATC document
ATC
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS
GeM-Bidding-8517919.pdf
Main Document
CATALOG-Specification-1
CATALOG Specification
Buyer uploaded ATC document
ATC
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS