| MAGNET | Magnet Configuration | Normal bore, Wide Bore |
| GANTRY | Bore diameter at isocenter (cm) | 60, 70 |
| GANTRY | Maximum bore length with cover (cm) | 140-149, 150-159, 160-169, 170-179, 180-189, 190 and above |
| SHIM SYSTEM | Type of shimming | Active, Passive, Active and Passive, Passive, linear and higher order active |
| PATIENT TABLE | Safe patient transfer cart provided | Yes, No |
| PATIENT TABLE | Table Type | Dockable, Fixed |
| PATIENT TABLE | Table movements | Vertical, Horizontal, Vertical and Horizontal |
| PATIENT TABLE | Lateral movement in Table | Yes, No |
| GRADIENT SYSTEM | Peak Amplitude with each axis independently mT/m | ≥ 30, ≥ 40, ≥ 60, ≥ 80 |
| GRADIENT SYSTEM | Standard slew rate, with each axis independently T/m/sec | ≥ 100, ≥ 200 |
| RF SYSTEM | Minimum RF transmitter and receiver power output (KW) | 20, 30, 40 |
| RF SYSTEM | Number of minimum independent / quadrature RF receiver channels that can be used simultaneously in one single scan and in one single FOV | 8, 16, 24, 32, 48, 64, 128, Digital imaging with direct digital interface and digital surround technology, ADC at the coil (channel independent) |
| RF SYSTEM | RF system's minimum number of elements that can be connected simultaneously in single FOV and single scan | 16, 24, 32, 48, 128, 204, Coil and FOV Dependent |
| COIL SYSTEM | Parallel imaging -uses redundant information acquired by multiple coil elements to significantly accelerate image acquisition The overall image time can be reduced by a factor of two or more | Yes, No |
| COIL SYSTEM | Head and Neck Coil - Number of elements (minimum) | 8, 10, 14, 16, 20, 32, 37, 48, 64 Or higher |
| COIL SYSTEM | Head and Neck coil, Detachable face - a detachable front section is Intended to help reduce patient anxiety | Yes, No |
| COIL SYSTEM | Head and Neck Coil, Patient mirror(s) - include a small mirror that enables the patient to see outside the bore, which can reduce patient anxiety | Yes, No |
| COIL SYSTEM | Spine Coil - Number of elements (minimum) | 12, 16, 18, 24, 32, 44, 60, 40 Or higher |
| COIL SYSTEM | Dedicated Anterior body Coil with Spine Coil (body imaging at Max FOV) 45cm (single or combination of coils) - Maximum elements used simultaneously | 9, 18, 29, 32, 36, 60, 12, 24, 6 Or higher |
| COIL SYSTEM | Breast Coil | Yes, No |
| COIL SYSTEM | Breast Coil - Number of elements (minimum) | 4, 7, 8, 16, 18, NA |
| COIL SYSTEM | Dedicated Breast Biopsy coil | Yes, No |
| COIL SYSTEM | Spine (CTL) | Yes, No |
| COIL SYSTEM | Head + Neck, Neuro-Vasculature | Yes, No |
| COIL SYSTEM | Whole CNS (Head + Whole Spine) | Yes, No |
| COIL SYSTEM | Chest, Heart | Yes, No |
| COIL SYSTEM | Abdomen, Pelvis | Yes, No |
| COIL SYSTEM | Whole Abdomen | Yes, No |
| COIL SYSTEM | Peripheral Vasculature | Yes, No |
| COIL SYSTEM | Prostate, Colon, Rectum, Cervix | Yes, No |
| COIL SYSTEM | Dedicated Knee Coil | Yes, No |
| COIL SYSTEM | Knee coil - number of elements | ≥ 8, ≥ 15, NA |
| COIL SYSTEM | Dedicated Ankle coil | Yes, No |
| COIL SYSTEM | Ankle coil - number of elements | ≥ 8, ≥ 16, NA |
| COIL SYSTEM | Dedicated Shoulder coils | Yes, No |
| COIL SYSTEM | Shoulder coil - number of elements | ≥ 3, ≥ 8, ≥ 15, NA |
| COIL SYSTEM | Wrist coil - number of elements | ≥ 8, ≥ 16, NA |
| COIL SYSTEM | Multi-Purpose Coils | Yes, No |
| COIL SYSTEM | Temporo-Mandibular Joints | Yes, No |
| COIL SYSTEM | Whole Body | Yes, No |
| COIL SYSTEM | Flex coils small and large at least 4 channel | Yes, No |
| COIL SYSTEM | Multi nuclear spectroscopy with one multinuclear coil | Yes, No |
| SCANNING TECHNIQUES | Standard pulse sequences (Series of RF and gradient pulses used to generate MR signals for image acquisition) | Yes, No |
| SCANNING TECHNIQUES | Image acquisition - Patient movement compensated, head and body | Yes, No |
| SCANNING TECHNIQUES | Isotropic 3-D (T1) and Isotropic 3-D fast spin echo (T2) | Yes, No |
| SCANNING TECHNIQUES | Fat supressed Single breath-hold 3-D body imaging using parallel acquisition of gradient echo pulse sequences | Yes, No |
| SCANNING TECHNIQUES | Single-point Dixon acquisition - this technique generates different image contrasts such as water-only, fat-only, in-phase, and out-of-phase | Yes, No |
| SCANNING TECHNIQUES | Gradient Echo - An imaging sequence in which echo is created by switching a pair of dephasing and rephasing gradients such as spoiled, rewound and Steady state free precession techniques | Yes, No |
| SCANNING TECHNIQUES | Spectroscopy for Breast | Yes, No |
| SCANNING TECHNIQUES | Spectroscopy for Prostate | Yes, No |
| SCANNING TECHNIQUES | multi parametric study for prostate | Yes, No |
| SCANNING TECHNIQUES | Bilateral Breast imaging with fat suppression with time intensity graph | Yes, No |
| SCANNING TECHNIQUES | Non-contrast angiographic imaging technique (time of flight, phase contrast and SSFP) is used to visualize flow within vessels | Yes, No |
| WORKSTATION QUANTITATIVE IMAGE ANALYSIS TOOLS | Neuro Perfusion imaging tools | Yes, No |
| WORKSTATION QUANTITATIVE IMAGE ANALYSIS TOOLS | fMRI tools | Yes, No |
| WORKSTATION QUANTITATIVE IMAGE ANALYSIS TOOLS | Diffusion Imaging tools | Yes, No |
| WORKSTATION QUANTITATIVE IMAGE ANALYSIS TOOLS | Diffusion tensor imaging tools | Yes, No |
| WORKSTATION QUANTITATIVE IMAGE ANALYSIS TOOLS | Cardiac imaging tools | Yes, No |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | Image post processing workstation model | Standalone, Client server |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | If it is server workstation, number of nodes to be provided | 1, 2, 3, 4, Not Applicable in case of Standalone Workstation |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | l necessary compatible and up gradable software including post processing software for all offered application including DTI and other associated post processing like MIP, MPR, and surface reconstruction to be provided | Yes, No |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | Software's for analyzing DWI, Spectroscopy, perfusion, CSF flow data, T1 relaxation, T2 relaxation, T2*relaxation to be provided | Yes, No |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | System should be capable of having number of DTI directions (minimum) | 12, 32, 128, 256 Or higher |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | Cardiac package for morphology and cardiac angiography | Yes, No |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | Output in the form of jpeg, avi /equivalent formats | Yes, No |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | Display of cardiac cine images in movie mode with rapid avi creation in workstation | Yes, No |
| SERVER HARDWARE | Image storage capacity of Server | ≥ 2 TB, Not Applicable in case of Standalone Workstation |
| SERVER HARDWARE | Minimum Processing Power of Server | 20,000 concurrent slices, Not Applicable in case of Standalone Workstation, 16,000 concurrent slices |
| SERVER HARDWARE | Ram Size of server | ≥ 32 GB, Not Applicable in case of Standalone Workstation |
| SERVER HARDWARE | Size of Monitor of Server | 19 inch or more, Not Applicable in case of Standalone Workstation |
| SERVER HARDWARE | Type of Monitor of Server | LCD/LED/TFT, Not Applicable in case of Standalone Workstation |
| WORKSTATION HARDWARE | Minimum Ram Size of Workstation | 4, 8, 16 Or higher |
| WORKSTATION HARDWARE | Minimum Storage capacity of Workstation | 500, 1000 Or higher |
| ACCESSORIES | MRI Compatible auto pressure injector | Yes, No |
| ACCESSORIES | MR Compatible basic ventillator | Yes, No |
| ACCESSORIES | MR Compatible Monitor (ECG, SpO2, NIBP, RR and HR/PR) with slave display in control room | Yes, No |
| ACCESSORIES | MR Compatible medical O2 gas pipeline with cylinder and standard accessories | Yes, No |
| ACCESSORIES | MRI Compatible trolley and wheel chair to transfer patient in and out of gantry room | Yes, No |
| ACCESSORIES | Dry laser camera with minimum resolution of 500 DPI and with three trays to accommodate three different size of films | Yes, No |
| ACCESSORIES | Online UPS for entire system for backup of at least 30 minutes | Yes, No |
| PRE-INSTALLATION SITE REQUIREMENTS | Preparation of MRI Room , console Room , Technical room, patient preparation room, one wash room etc to be done by the seller in the area of approx 900 Sq feet | Yes, No |
| PRE-INSTALLATION SITE REQUIREMENTS | Vinyl flooring, wooden panels and good quality false ceiling in MRI room to be done by the seller | Yes, No |
| PRE-INSTALLATION SITE REQUIREMENTS | Tile based false ceiling and floor tiling and wall tiling till false ceiling in rooms other than MRI room to be done by the seller | Yes, No |
| PRE-INSTALLATION SITE REQUIREMENTS | Necessary modification civil work, electrical , plumbing, furnishing, air conditioning in the given area to be done by the seller | Yes, No |
| PRE-INSTALLATION SITE REQUIREMENTS | Doors other than main MRI room to be of good quality Aluminium doors and to be done by the seller | Yes, No |
| PRE-INSTALLATION SITE REQUIREMENTS | RF shielding for doors, wall, glass viewer etc to be done by the seller | Yes, No |
| WARRANTY | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5, 2, 3 Or higher |