View Catalog| Category | Specification | Requirement | 
|---|---|---|
| GENERAL | Product Description | 5 Part Automated Hematology Analyser | 
| PRODUCT INFORMATION | Type of Configuration | Benchtop | 
| PRODUCT INFORMATION | Type of system offered | Closed system | 
| PRODUCT INFORMATION | Type of automation | Fully Automatic | 
| PRODUCT INFORMATION | Equipment should have automatic start up,shut down and sample analysis | Yes | 
| PRODUCT INFORMATION | Analysis principle | Based on principle of counting and sizing, Laser based scatter analysis | 
| PRODUCT INFORMATION | Type of cell counting | 5 part WBC differential with Retics and NBRC enumeration capability | 
| PRODUCT INFORMATION | Should have multi channel analysis for better resolution and reproductability | Yes | 
| PRODUCT INFORMATION | Analysis available | WBC, Lympho#, Lympho%, Neutrophil#, Neutrophil %, Basophil#, Basophil%, Easinophil #, Easinophil%, Monocyte#, Monocyte%, RBC, HGB, MCV, PCV, MCH, MCHC, RDW-SD, RDW CV, PLT, MPV, PDW, PLT, PLCR, PLCC, HCT, PCT, RET#, RET%, NRBC#, WBC, Lympho#, Lympho%, Neutrophil#, Neutrophil %, Basophil#, Basophil%, Easinophil #, Easinophil%, Monocyte#, Monocyte%, RBC, HGB, MCV, PCV, MCH, MCHC, RDW-SD, RDW CV, PLT, MPV, PDW, PLT, PLCR, HCT, PCT | 
| PRODUCT INFORMATION | NRBC% | No | 
| PRODUCT INFORMATION | Availability of body fluid (CSF, synovial, serous) parameters like WBC-BF, RBC-BF, MN#, MN%, PMN%, PMN#,TC-BF# | No | 
| PRODUCT INFORMATION | IPF analysis | No | 
| PRODUCT INFORMATION | PLT-0 Analysis | No | 
| PRODUCT INFORMATION | PLT-F Analysis | No | 
| PRODUCT INFORMATION | IG % analysis | No | 
| PRODUCT INFORMATION | IG# analysis | No | 
| PRODUCT INFORMATION | RET-HE analysis | No | 
| PRODUCT INFORMATION | HFR analysis | No | 
| PRODUCT INFORMATION | LFR analysis | No | 
| PRODUCT INFORMATION | MFR analysis | No | 
| PRODUCT INFORMATION | IRFanalysis | No | 
| PRODUCT INFORMATION | Discrete analysis modes available | CBC,CBC+DIFF | 
| PRODUCT INFORMATION | Analysis method for WBC | Dual differential count, Tri-angle Laser flow cytometry | 
| PRODUCT INFORMATION | Method for platelet measurement | Electrical impedance | 
| PRODUCT INFORMATION | RBC Measurement method | Electrical Impedance | 
| PRODUCT INFORMATION | Hb measurement | Photometric/direct cellular measurement, Cyanide free colorimetry | 
| PRODUCT INFORMATION | Retic measurement | On board light scatter (fluorescent dye/retic stain based) for reticulocytes, Not provided | 
| PRODUCT INFORMATION | Number of sample racks to cater to different tube sizes | 1, 6 | 
| PRODUCT INFORMATION | Maximum sample Aspiration volume needed in all modes | 100 Β΅l or less, 20Β΅l or less | 
| PRODUCT INFORMATION | Minimum sample volume required in all modes | 20Β΅l or less | 
| PRODUCT INFORMATION | Throughput capacity in CBC/Differential | 50-60, 71-80, 90-100 | 
| PRODUCT INFORMATION | Throughput capacity in Retic mode | 45 or more, NA | 
| PRODUCT INFORMATION | Type of modes of sample running | Closed vial | 
| PRODUCT INFORMATION | Linearity of Platelet | 0 to 3000 * 10 3 cells/ micro litres | 
| PRODUCT INFORMATION | RBC Linearity | 0 to 8 x 10^6 per micro litre or more | 
| PRODUCT INFORMATION | Hemoglobin linearity | 0 to 25 gm per litre | 
| PRODUCT INFORMATION | Retic linearity | 0 to 24.5, NA | 
| PRODUCT INFORMATION | WBC linearity | 0 to 300 * 1000 cells/ micro litres | 
| PRODUCT INFORMATION | Directly measures MCV | Yes | 
| PRODUCT INFORMATION | Time taken by the analyser to produce the test results(Analysis time) in seconds | 40-60 | 
| PRODUCT INFORMATION | Availability of Auto dilution | Yes, No | 
| PRODUCT INFORMATION | Clot detection facility | No, Yes | 
| PRODUCT INFORMATION | Automatic probe wipe | Yes | 
| PRODUCT INFORMATION | Extended Analyses for cytopenic samples | Yes | 
| PRODUCT INFORMATION | Quality assurance system with calibration and controls | Yes | 
| PRODUCT INFORMATION | Number of quality control programs | Atleast 3 | 
| PRODUCT INFORMATION | Type of Calibration | Both manual and automatic | 
| PRODUCT INFORMATION | Direct aspiration for capillary blood from finger prick | No, Yes | 
| PRODUCT INFORMATION | Floating discriminator for platelets and RBC counting for reliable RBC and PLT data | Yes | 
| PRODUCT INFORMATION | Separate diluting nozzles for RBC and WBC | Yes | 
| PRODUCT INFORMATION | Double bathing mechanism | Yes | 
| PRODUCT INFORMATION | Upgradable to integrate with attachment | No | 
| Data Management and Display | Type of data management | PC based, In-built system | 
| Data Management and Display | Display | TFT, LCD, LED Or higher | 
| Data Management and Display | PC hard disk | >500 GB, NA | 
| Data Management and Display | Inbuilt monitor size in inches | >5, NA (for PC based) | 
| Data Management and Display | Processor of PC Provided with system | I5 or more, NA (If PC not provided) | 
| Data Management and Display | RAM | 4 GB, NA (If PC not provided) | 
| Data Management and Display | HDD | 500 GB, NA (If PC not provided) | 
| Data Management and Display | PC Monitor size if PC provided externally | 17 inches or more, NA (for Inbuilt based) | 
| Data Management and Display | The processor and RAM of the board system should be latest version | Yes | 
| Data Management and Display | HIS/LIS Interface | HL7 | 
| Data Management and Display | Type of external storage | USB, SD Card | 
| Data Management and Display | Number of USB Port provided | 3, 4 | 
| Data Management and Display | Type of printer unit | External | 
| Data Management and Display | Printer type | Black and White Laser Printer, Colour Laser Printer | 
| Data Management and Display | Display and print provided | Scatter plot and histograms | 
| Data Management and Display | Auto loader facility | Yes | 
| Data Management and Display | Facility for user defined flagging | Yes | 
| Data Management and Display | Database capability of storing sets of results and graphics | β₯ 10000 to 20000, β₯ 50000 | 
| Data Management and Display | L J Plot facility | Yes | 
| Data Management and Display | Delta check for cumulative review | Yes | 
| Data Management and Display | On-line QC option | Yes | 
| Data Management and Display | Patient moving average | Yes | 
| Data Management and Display | QC File management | Yes | 
| Data Management and Display | Facility for workload recording | Yes | 
| Data Management and Display | Flagging in event of unacceptable control data | Yes | 
| Data Management and Display | Ability to transmit results to host computer | Yes | 
| Data Management and Display | Type of user Interface or data entry | Touchscreen, Handheld barcode reader facility, Manual | 
| Data Management and Display | Have auto cleaning function in the analyserβs software | Yes | 
| POWER REQUIREMENTS | Type of power supply | 100-240 VAC,50-60 Hz | 
| POWER REQUIREMENTS | Power Backup facility | UPS | 
| POWER REQUIREMENTS | Type of UPS | Online | 
| POWER REQUIREMENTS | Rating of UPS in KVA | 0.5 | 
| POWER REQUIREMENTS | Availability of Sufficient Number of Quality control files which store 100 or more XB Analysis | Yes | 
| ACCESSORIES, SPARE PARTS AND CONSUMABLES | Offered equipment unit to be supplied with sufficient consumables (with at least 2/3rd of total shelf life) required for, sufficient to carry out haematological testing of samples" | 500 | 
| ACCESSORIES, SPARE PARTS AND CONSUMABLES | Should have on board reagent facility and automatic reagent inventory management | Yes | 
| ACCESSORIES, SPARE PARTS AND CONSUMABLES | Net work integration with lab information system feature | Yes | 
| ACCESSORIES, SPARE PARTS AND CONSUMABLES | Operating temperature and humidity | Capable of operating continuously in ambient temperature of 10 to 35 deg C and relative humidity of 15 to 85% in ideal circumstances | 
| CERTIFICATION AND REPORTS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes | 
| CERTIFICATION AND REPORTS | Availability of valid drug license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes | 
| CERTIFICATION AND REPORTS | Manufacturing unit certification | ISO:13485 (Latest) | 
| CERTIFICATION AND REPORTS | Availability of Test Report for product as per Medical Device Rules (MDR) 2017 as amended till date | Yes | 
| CERTIFICATION AND REPORTS | Electrical Safety Standards | IEC/EN 60601-1 or equivalent BIS Standard | 
| CERTIFICATION AND REPORTS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement | Yes | 
| WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5 Or higher | 
| MISCELLANEOUS REQUIREMENTS | OEM/Reseller shall ensure uninterrupted availability of all spares for 10 years | Yes | 
| MISCELLANEOUS REQUIREMENTS | Availability of toll free facility for technical support maintened by OEM or authorized agencies | Yes | 
| MISCELLANEOUS REQUIREMENTS | User/Technical/Maintenance manuals to be supplied in English in hard and soft copy | Yes | 
| MISCELLANEOUS REQUIREMENTS | Details of equipments and procedures required for local calibration and routine maintenance to be supplied and advanced maintenance task documentation also to be furnished | Yes | 
| MISCELLANEOUS REQUIREMENTS | List of important spares and accessories, with their part numbers to be supplied to the buyer at the time of supplying the equipment | Yes | 
| MISCELLANEOUS REQUIREMENTS | Installation and Demonstration of equipment and training to be provided after completing supplies before acceptance | Yes | 
| MISCELLANEOUS REQUIREMENTS | The Principal Manufacturer must have direct Presence/approved service center In India | Yes | 
| MISCELLANEOUS REQUIREMENTS | Calibration certificates as per NABH requirement | Yes | 
| MISCELLANEOUS REQUIREMENTS | Time to attend breakdown calls | within 48 hrs | 
AI-Powered Bidder Prediction
Companies most likely to bid
Unlock Bidder Insights
AI predictions on likely bidders
Required Documents
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
   
Similar Tenders
 5 Part Automated Hematology Analyser (V2)
Department of Health and Family Welfare
AIZAWL, MIZORAM
Download FREE!
Access all tender documents at no cost
    Documents  3  
 GeM-Bidding-8432842.pdf
Main Document
CATALOG-Specification-1
CATALOG Specification
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS
GeM-Bidding-8432842.pdf
Main Document
CATALOG-Specification-1
CATALOG Specification
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS