The pipeline installation must conform to IS standards for water pipelines and civil construction. The RCC pipes should have a diameter of 600 mm, with a minimum compressive strength of 5 MPa. The joints should be sealed using approved jointing materials to prevent leakage. The trench dimensions should be in accordance with the technical drawings provided in the tender documents. The installation process involves sequential laying, jointing, and testing. The pressure testing must ensure the pipeline withstands at least 1.5 times the operating pressure. The technical parameters are summarized below:
| Parameter |
Specification |
| Pipe Diameter |
600 mm |
| Material |
Reinforced Cement Concrete |
| Strength |
Minimum 5 MPa |
| Joint Type |
Rubber gasket or equivalent |
| Testing Pressure |
1.5 times operational pressure |
Sequential procedures include site survey, trench excavation, pipe laying, joint sealing, pressure testing, and site restoration.