Cassette AC 2Tr,Hi wall Split AC 2.0 Tr,Hi wall Split AC 1.5 Tr,Installation of cassette AC,Install
State Bank Of India (sbi)
LUCKNOW, UTTAR PRADESH
Menu
Bid Publish Date
15-Dec-2025, 1:53 pm
Bid End Date
29-Dec-2025, 3:00 pm
EMD
₹35,000
Value
₹40,40,615
Location
Progress
Quantity
2231
State Bank Of India (sbi) announces a tender for 28 HP heat pump outdoor VRV OR VRF, 26 HP heat pump outdoor VRV OR VRF, 4 Way 3. 0 Tr VRF Cassette Indoor, 4 Way 2. 0 Tr VRF Cassette Indoor, 4 Way 1. 6 Tr VRF Cassette Indoor, 4 Way 1. 3 Tr VRF Cassette Indoor, 4 Way 1. 0 Tr VRF Cassette Indoor, 1. 6 Tr VRF HI wall split Indoor, 1. 0 Tr VRF HI wall split Indoor, 4 Way 2. 0 Tr 5 star Cassette AC, 2. 0 Tr 5 star Hi Wall Split AC, 1. 5 Tr 5 star Hi Wall Split AC, Installation of VRV OR VRF Outdoor, Installation of VRV OR VRF cassette Indoor, Installation of VRV OR VRF split Indoor, Installation of cassette AC, Installation of Hi wall Split AC, Refrigerant piping 34. 9 mm, Refrigerant piping 31. 8 mm, Refrigerant piping 28. 6 mm, Refrigerant piping 22. 2 mm, Refrigerant piping 19. 1 mm, Refrigerant piping 15. 9 mm, Refrigerant piping 12. 7 mm, Refrigerant piping 9. 5 mm, Refrigerant piping 6. 4 mm, Additional Copper pipe for cassettre AC, Additional Copper pipe for split AC, Drain pipe 32 mm, Drain pipe 25 mm, Control and Transmission wiring, Control wiring for cassette and split AC, Cable Tray, Outdoor Stand for VRV or VRF, Outdoor Stand for cable and split AC, Stabiliser 5. 0 KVA, Stabiliser 4 KVA, Core Cutting in LUCKNOW, UTTAR PRADESH. Quantity: 2231. Submission Deadline: 29-12-2025 15: 00: 00. Last date to apply is approaching fast!
State Bank Of India (sbi)
LUCKNOW, UTTAR PRADESH
State Bank Of India (sbi)
LUCKNOW, UTTAR PRADESH
State Bank Of India (sbi)
State Bank Of India (sbi)
LUCKNOW, UTTAR PRADESH
State Bank Of India (sbi)
LUCKNOW, UTTAR PRADESH
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | 28 HP heat pump outdoor VRV OR VRF | Supply of air cooled 28 HP Outdoor units suitable for cooling and heating. Refer technical specification and BOQ for details. | 2 | nos | sbilholuc.buy_con9 | 75 |
| 2 | 26 HP heat pump outdoor VRV OR VRF | Supply of air cooled 26 HP Outdoor units suitable for cooling and heating. Refer technical specification and BOQ for details. | 1 | nos | sbilholuc.buy_con9 | 75 |
| 3 | 4 Way 3.0 Tr VRF Cassette Indoor | Supply of ceiling suspended 4-way VRF/VRV Cassette type 3.0 Tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. Refer technical specification and BOQ for details. | 11 | nos | sbilholuc.buy_con9 | 75 |
| 4 | 4 Way 2.0 Tr VRF Cassette Indoor | Supply of ceiling suspended 4-way VRF/VRV Cassette type 2.0 Tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. Refer technical specification and BOQ for details. | 8 | nos | sbilholuc.buy_con9 | 75 |
| 5 | 4 Way 1.6 Tr VRF Cassette Indoor | Supply of ceiling suspended 4-way VRF/VRV Cassette type 1.6 Tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. Refer technical specification and BOQ for details. | 4 | nos | sbilholuc.buy_con9 | 75 |
| 6 | 4 Way 1.3 Tr VRF Cassette Indoor | Supply of ceiling suspended 4-way VRF/VRV Cassette type 1.3 Tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. Refer technical specification and BOQ for details. | 2 | nos | sbilholuc.buy_con9 | 75 |
| 7 | 4 Way 1.0 Tr VRF Cassette Indoor | Supply of ceiling suspended 4-way VRF/VRV Cassette type 1.0 Tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. Refer technical specification and BOQ for details. | 7 | nos | sbilholuc.buy_con9 | 75 |
| 8 | 1.6 Tr VRF HI wall split Indoor | Supply of wall mounted VRF/VRV Hi wall split type 1.6 Tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. Refer technical specification and BOQ for details. | 1 | nos | sbilholuc.buy_con9 | 75 |
| 9 | 1.0 Tr VRF HI wall split Indoor | Supply of wall mounted VRF/VRV Hi wall split type 1.0 Tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. Refer technical specification and BOQ for details. | 2 | nos | sbilholuc.buy_con9 | 75 |
| 10 | 4 Way 2.0 Tr 5 star Cassette AC | Supply of ceiling suspended 4-way 5 star Cassette type 2.0 Tr AC unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. Refer technical specification and BOQ for details. | 1 | nos | sbilholuc.buy_con9 | 75 |
| 11 | 2.0 Tr 5 star Hi Wall Split AC | Supply of 2.0 Tr 5 star inverter Hi wall split AC unit with full function wireless remote and auto restart feature. Refer technical specification and BOQ for details. | 3 | nos | sbilholuc.buy_con9 | 75 |
| 12 | 1.5 Tr 5 star Hi Wall Split AC | Supply of 1.5 Tr 5 star inverter Hi wall split AC unit with full function wireless remote and auto restart feature. Refer technical specification and BOQ for details. | 4 | nos | sbilholuc.buy_con9 | 75 |
| 13 | Installation of VRV OR VRF Outdoor | Installation, testing and commissioning of VRV/VRF outdoor with necessary stand, Gas etc. including making good of damages complete in all respects. | 3 | nos | sbilholuc.buy_con9 | 75 |
| 14 | Installation of VRV OR VRF cassette Indoor | Installation, testing and commissioning of VRV/VRF cassette indoor with necessary stand, Gas etc. including making good of damages complete in all respects. | 32 | nos | sbilholuc.buy_con9 | 75 |
| 15 | Installation of VRV OR VRF split Indoor | Installation, testing and commissioning of VRV/VRF split indoor with necessary stand, Gas etc. including making good of damages complete in all respects. | 3 | nos | sbilholuc.buy_con9 | 75 |
| 16 | Installation of cassette AC | Installation, testing and commissioning of 2 Tr cassette conditioner with wall cutting/ mounting, stabiliser and making good of damages complete in all respects. | 1 | nos | sbilholuc.buy_con9 | 75 |
| 17 | Installation of Hi wall Split AC | Installation, testing and commissioning of 2/ 1.5/ 1 TR Hi wall type split/window air conditioner with wall cutting/ mounting, stabiliser and making good of damages complete in all respects. | 7 | nos | sbilholuc.buy_con9 | 75 |
| 18 | Refrigerant piping 34.9 mm | Supply, installation, testing and commissioning of Interconnecting 34.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details. | 80 | rmt | sbilholuc.buy_con9 | 75 |
| 19 | Refrigerant piping 31.8 mm | Supply, installation, testing and commissioning of Interconnecting 31.8 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details. | 50 | rmt | sbilholuc.buy_con9 | 75 |
| 20 | Refrigerant piping 28.6 mm | Supply, installation, testing and commissioning of Interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details. | 80 | rmt | sbilholuc.buy_con9 | 75 |
| 21 | Refrigerant piping 22.2 mm | Supply, installation, testing and commissioning of Interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details. | 30 | rmt | sbilholuc.buy_con9 | 75 |
| 22 | Refrigerant piping 19.1 mm | Supply, installation, testing and commissioning of Interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details. | 40 | rmt | sbilholuc.buy_con9 | 75 |
| 23 | Refrigerant piping 15.9 mm | Supply, installation, testing and commissioning of Interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details. | 160 | rmt | sbilholuc.buy_con9 | 75 |
| 24 | Refrigerant piping 12.7 mm | Supply, installation, testing and commissioning of Interconnecting 12.7 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details. | 50 | rmt | sbilholuc.buy_con9 | 75 |
| 25 | Refrigerant piping 9.5 mm | Supply, installation, testing and commissioning of Interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details. | 120 | rmt | sbilholuc.buy_con9 | 75 |
| 26 | Refrigerant piping 6.4 mm | Supply, installation, testing and commissioning of Interconnecting 6.4 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details. | 40 | rmt | sbilholuc.buy_con9 | 75 |
| 27 | Additional Copper pipe for cassettre AC | Supply, installation, testing and commissioning of insulated copper refrigerant piping set (suction and discharge) duly insulated by nitrile rubber for 2/1.5 TR cassette AC. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details. | 40 | rmt | sbilholuc.buy_con9 | 75 |
| 28 | Additional Copper pipe for split AC | Supply, installation, testing and commissioning of insulated copper refrigerant piping set (suction and discharge) duly insulated by nitrile rubber for 2/1.5/1 TR hi wall split AC. Size (thickness and diameter) of both Copper pipes. Refer technical specification and BOQ for details. | 90 | rmt | sbilholuc.buy_con9 | 75 |
| 29 | Drain pipe 32 mm | Supply, installation, testing and commissioning of UPVC 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. Refer technical specification and BOQ for details. | 160 | rmt | sbilholuc.buy_con9 | 75 |
| 30 | Drain pipe 25 mm | Supply, installation, testing and commissioning of UPVC 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. Refer technical specification and BOQ for details. | 80 | rmt | sbilholuc.buy_con9 | 75 |
| 31 | Control and Transmission wiring | Supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. Refer technical specification and BOQ for details. | 550 | rmt | sbilholuc.buy_con9 | 75 |
| 32 | Control wiring for cassette and split AC | Supply, installation, testing and commissioning of inter connecting wiring/ cabling between indoor and outdoor of Cassette and hi wall type split AC (power supply will be made available at the outdoor or indoor unit as per the site AC requirement, please quote accordingly). Refer technical specification and BOQ for details. | 150 | rmt | sbilholuc.buy_con9 | 75 |
| 33 | Cable Tray | Supply & Laying of Cable Tray 300 mm GI for Copper Pipes & Cables | 260 | rmt | sbilholuc.buy_con9 | 75 |
| 34 | Outdoor Stand for VRV or VRF | Supply and installation of robust MS angle, MS flat fabricated floor/ wall mounting stand suitable for VRF/ VRV outdoor units. Refer technical specification and BOQ for details. | 3 | nos | sbilholuc.buy_con9 | 75 |
| 35 | Outdoor Stand for cable and split AC | Supply and installation of robust MS angle, MS flat fabricated floor/ wall mounting stand suitable for hi wall split/ cassette outdoor units. Refer technical specification for details. | 8 | nos | sbilholuc.buy_con9 | 75 |
| 36 | Stabiliser 5.0 KVA | Supply of 5.0 KVA, wall mounted hi lo cut off stabiliser with TDR, voltage range 140-280V, complete in all respects. Refer technical specification for details. | 4 | set | sbilholuc.buy_con9 | 75 |
| 37 | Stabiliser 4 KVA | Supply of 4 KVA, wall mounted hi lo cut off stabiliser with TDR, voltage range 140-280V, complete in all respects. Refer technical specification for details. | 4 | set | sbilholuc.buy_con9 | 75 |
| 38 | Core Cutting | Core cutting/ wall chiseling upto 75mm width and 50 mm depth for concealing the copper pipe, drain pipe and conduit either on wall or under floor including making good of damages with plaster, putti and paint. | 140 | mtr | sbilholuc.buy_con9 | 75 |