| Category | Specification | Requirement |
|---|---|---|
| GENERAL FEATURES | Product Description | Hemoglobinometer |
| PRODUCT INFORMATIONS | Type | Portable & Handheld |
| PRODUCT INFORMATIONS | Parameter Measured | Hemoglobin (Hb) Level |
| PRODUCT INFORMATIONS | Sample Size | ≤50 microliters (µL) |
| PRODUCT INFORMATIONS | Sample Mode | Strip |
| PRODUCT INFORMATIONS | Accuracy | ≥98% Or higher |
| PRODUCT INFORMATIONS | Reproducibility (intra sample variation) | Less than 5% Or higher |
| PRODUCT INFORMATIONS | Testing Time | ≤60 seconds Or higher |
| PRODUCT INFORMATIONS | Provision for data transfer to PC | Yes |
| PRODUCT INFORMATIONS | Connectivity | USB, Bluetooth |
| PRODUCT INFORMATIONS | Zero Setting | Automatic |
| PRODUCT INFORMATIONS | Calibration | Automatic Calibration |
| PRODUCT INFORMATIONS | Self-checking Facility available between every measurement | Yes |
| PRODUCT INFORMATIONS | Shut off system | Automatic |
| PRODUCT INFORMATIONS | Original literature of equipment provided | Yes |
| POWER REQUIREMENTS | Power supply | Battery Operated |
| POWER REQUIREMENTS | Type of Battery | Rechargeable |
| POWER REQUIREMENTS | Battery charger provided in case of rechargeable battery operated | Yes |
| POWER REQUIREMENTS | Fully Charged Battery Life (Number of Measurements) | ≥500 Or higher |
| ACCESESSORIES | Number of Lancets supplied with the instrument | 50 |
| ACCESESSORIES | Number of compatible hemoglobin strips supplied with the instrument | 50 |
| CERTIFICATIONS & REPORTS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Availability of valid drug license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Manufacturing unit certification | ISO:13485 (Latest) |
| CERTIFICATIONS & REPORTS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Compliance to Electrical Safety Standards | IEC 60601-1 or equivalent BIS Standard |
| Miscellaneous Parameters | User / Technical / Maintenance manuals to be supplied in English in hard and soft copy | Yes |
| Miscellaneous Parameters | Demonstration and training to be provided at consignee end | Yes |
| ADVANCE SAMPLE | Agree to provide advance sample of the product for buyer's approval before commencement of supply in case of bidding | Yes |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Access all tender documents at no cost
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS