TenderDekho Logo
Repair Of Air Condition Plant state-wide in Rajasthan

Repair Of Air Condition Plant Tenders in Rajasthan

Access live Repair Of Air Condition Plant procurement tenders in Rajasthan state

Location
Authority
0

Dismentaling of the existing split type AC Units,General Servicing of 1.5 or 2.0 TR Split AC units,

Bharat Sanchar Nigam Limited Portal(bsnl)

JODHPUR, RAJASTHANPosted 10 Nov
₹3.3 L
GEMGoods4 Documents
Category: Dismentaling of the existing split type AC Units , General Servicing of 1.5 or 2.0 TR Split AC units , Installation, Testing and Commissioning of the Split AC units , Replacement of the 1.5 TR capacity compressor , Charging of Refrigerant gas , Supplying and fixing Starting Capacitor , Supplying and fixing Running Capacitor , Supplying and fixing fan motor capacitor , PCB card for indoor unit of inverter type Split AC , PCB card for outdoor unit of inverter type Split AC , Condenser or Blower fan blade suitable for existing model , Condenser or Blower fan motor suitable for existing model , Rewinding of existing all type Blower or condenser fan motor , Provision of Top up of R-22 or R-410 or R-407 refrigerant gas , Supplying and laying 3 core 2.5sqmm PVC insulated and PVC sheathed flexible copper cable , Supplying and laying 4 core 2.5sqmm PVC insulated and PVC sheathed flexible copper cable , Supply and Fixing of 20 mmdia Medium UPVC pipe for drain , Providing nd fixing 12mm thick Exterior grade ISI mark both side laminated particle board , Supply and fixing of 4feet long, 18 watt LED lighting fixture , Providing and fixing 1 by 4 inch size extra refrigerant copper piping , Providing and fixing 5 by 8 inch size extra refrigerant copper piping , Providing and fixing 7 by 8 inch size extra refrigerant copper piping , Providing and fixing 1 by 2 inch size extra refrigerant copper piping , SITC Including Fabricating 100mm width x 50mm x 1.6mm thickness size of perforated MS cable tray , SITC Including Fabricating 150mm width x 50mm x 1.6mm thickness size of perforated MS cable tray , Supply and fixing of 35mm X 35mm X 5mm size MS Angle iron , Supply and fixing of 25mm X 25mm X 3mm size MS Angle iron , Supply and fixing of 25mm X 3mm size MS Flat , Supply and fixing 1cm X 1cm squre MS wire mesh of 3mm thick wire
Deadline
2 Dec 2025
View Details

Labour Charges for Service and maintenance of 1.5T and 2.0T AC,Labour Charges for Routine or Breakd

Indo Tibetan Border Police (itbp)

ALWAR, RAJASTHANPosted 13 Jun
₹30.3 L
EMD: ₹60,595
GEMGoods4 Documents
Category: Labour Charges for Service and maintenance of 1.5T and 2.0T AC , Labour Charges for Routine or Breakdown Service and maintenance of 8.5T AC , Labour Charges for Service and maintenance and maintenance of VRV and VRF , Labour Charges for Service and maintenance Air Waher ventilators and Scrubbers , chemical and other items required for Servicing of AC, VRV and VRFs , Topping up with suitable cooling gas of refrigerant in AC, VRV and VRF units , Replacement of Running capacitor 36 mfd, 240 V of 1.5T, 2.0T and 8.5T AC , Replacement of Running capacitor 45 to 50 mfd, 240 V of 1.5T, 2.0T and 8.5T AC , Replacement of Motor capacitor 2.5 mfd, 240 V of 1.5T, 2.0T and 8.5T AC , Replacement of Motor capacitor 4 mfd, 240 V of 1.5T, 2.0T and 8.5T AC , Replacement of Indoor Fan Motor of 1.5T, 2.0T and 8.5T AC , Replacement of Outdoor Fan Motor of 1.5T, 2.0T and 8.5T AC , Replacement of Condenser Coil of 1.5T, 2.0T and 8.5T AC , Replacement of Cooling Coil of 1.5T, 2.0T and 8.5T AC , Supplying and Replacement of PCB For 1.5TR and 2.0 TR inverter AC , Supplying and Replacement of PCB For 8.5 TR AC , Repairing of PCB For 1.5TR and 2.0 TR inverter AC. , Repairing of PCB For 8.5 TR inverter AC. , Replacement of old burnt or defective compressor 1.5 TR AC Compressor , Replacement of old burnt or defective compressor 2 TR AC Compressor , Replacement of old burnt or defective compressor 8.5 TR AC Compressor , Replacement of Magnet Switch for VRV and VRF , Replacement of Motor capacitor 2-5 mfd, 240 V for VRV and VRF , Replacement of Motor capacitor 4 mfd, 240 V for VRV and VRF , Replacement of Outdoor Fan Motor for VRV and VRF , Replacement of Condenser Coil for VRV and VRF , Replacement of Cooling Coil for VRV and VRF , Replacement of old burnt compressor for Hot and cold type VRV and VRF , Repairing of 8 to 12.5 HP Monoblock pumps , Repairing of 1 to 2 HP Monoblock pumps , Repairing and Re-installation of Starters for various pumps in air ventilators , Replacement of old burnt Starters for various pumps in air ventilators , Replacement of old burnt connectors and Contactors for pumps
Deadline
4 Jul 2026
View Details