Temperature Thermometer SA0060P002,Condensor Safety Valve BM2318,Suction Pressure Guage 9026107411,
Controller General Of Defence Accounts
NORTH AND MIDDLE ANDAMAN, ANDAMAN & NICOBAR
Progress
Quantity
171
Category
ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 100DEG C WITH 30MM THERMOWELL
Bid Type
Two Packet Bid
The procurement is issued by Cochin Shipyard Ltd under the Department of Public Enterprises for the supply of multiple 1 by 4 inch BSP M.S. Bourdon tube pressure gauges (0-6, 0-10, 0-16, 0-60 bar), and alcohol-filled thermometers with varying thermowell lengths (30 mm, 63 mm, 100 mm, 160 mm) across temperature ranges 0-100°C to 0-120°C. The scope covers ten BOQ items, with unspecified quantities in the available data but a clear product mix: pressure gauges with ROOT VALVE and thermometers of several configurations. The tender is located in Ernakulam, Kerala and targets the procurement of standard instrumentation components for marine/shipbuilding applications, potentially requiring IS/IEC or OEM-compliant products. A notable bid clause allows quantity variations up to ±25% with extended delivery windows, signaling flexible yet defined delivery commitments.
1 by 4 inch BSP M.S. Bourdon tube pressure gauges with ROOT VALVE
0-6 BAR, 0-10 BAR, 0-16 BAR, 0-60 BAR pressure ranges
Alcohol-filled straight-type thermometers with 30 mm, 63 mm, 100 mm, 160 mm thermowells
Temperature ranges: 0-100°C, 0-120°C
Dial and stem configurations: straight type; BSP mounting
Quantity variation up to 25% at any stage of contract
Extended delivery period aligns with option clause
Compliance with ATC documents and OEM authorizations mandatory
Payment details to be defined in ATC; verify milestones and acceptable payment schedule in tender terms.
Delivery must adhere to original delivery period with potential extension per option clause; additional time calculated as (additional quantity/original quantity) × original delivery period, minimum 30 days.
Penalty provisions not specified in provided data; refer to ATC for LD rates and conditions.
Must meet OEM authorization requirements as per ATC
Proven experience supplying marine/instrumentation gauges and thermometers
Financial capability evidenced by recent financial statements
Controller General Of Defence Accounts
NORTH AND MIDDLE ANDAMAN, ANDAMAN & NICOBAR
National Fertilizers Limited (nfl)
ROHTAK, HARYANA
Hcsl
HOWRAH, WEST BENGAL
Indian Navy
RAIGAD, MAHARASHTRA
Hindustan Petroleum Corporation Ltd
BAREILLY, UTTAR PRADESH
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | 1 BY 4 INCH BSP_M_SS BOURDON TUBE TYPE PRESSURE GAUGE WITH ROOT VALVE 0 TO 6 BAR | 1 BY 4 INCH BSP_M_SS BOURDON TUBE TYPE PRESSURE GAUGE WITH ROOT VALVE 0 TO 6 BAR | 4 | pieces | sm_general_stores | 45 |
| 2 | 1 BY 4 INCH BSP_M_SS BOURDON TUBE TYPE PRESSURE GAUGE WITH ROOT VALVE 0 TO 10 BAR | 1 BY 4 INCH BSP_M_SS BOURDON TUBE TYPE PRESSURE GAUGE WITH ROOT VALVE 0 TO 10 BAR | 12 | pieces | sm_general_stores | 45 |
| 3 | 1 BY 4 INCH BSP_M_SS BOURDON TUBE TYPE PRESSURE GAUGE WITH ROOT VALVE 0 TO 16 BAR | 1 BY 4 INCH BSP_M_SS BOURDON TUBE TYPE PRESSURE GAUGE WITH ROOT VALVE 0 TO 16 BAR | 16 | pieces | sm_general_stores | 45 |
| 4 | 1 BY 4 INCH BSP_M_SS BOURDON TUBE TYPE PRESSURE GAUGE WITH ROOT VALVE 0 TO 60 BAR | 1 BY 4 INCH BSP_M_SS BOURDON TUBE TYPE PRESSURE GAUGE WITH ROOT VALVE 0 TO 60 BAR | 5 | pieces | sm_general_stores | 45 |
| 5 | ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 100DEG C WITH 30MM THERMOWELL | ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 100DEG C WITH 30MM THERMOWELL | 7 | pieces | sm_general_stores | 45 |
| 6 | ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 100DEG C WITH 100MM THERMOWELL | ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 100DEG C WITH 100MM THERMOWELL | 3 | pieces | sm_general_stores | 45 |
| 7 | ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 120DEG C WITH 30MM THERMOWELL | ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 120DEG C WITH 30MM THERMOWELL | 15 | pieces | sm_general_stores | 45 |
| 8 | ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 120DEG C WITH 63MM THERMOWELL | ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 120DEG C WITH 63MM THERMOWELL | 57 | pieces | sm_general_stores | 45 |
| 9 | ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 120DEG C WITH 100MM THERMOWELL | ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 120DEG C WITH 100MM THERMOWELL | 45 | pieces | sm_general_stores | 45 |
| 10 | ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 120DEG C WITH 160MM THERMOWELL | ALCOHOL FILLED STRAIGHT TYPE THERMOMETER 0 to 120DEG C WITH 160MM THERMOWELL | 7 | pieces | sm_general_stores | 45 |
Discover companies most likely to bid on this tender
GST registration certificate
Permanent Account Number (PAN) card
Experience certificates for similar instrumentation supply
Financial statements (financial capability)
EMD/Security deposit documents (as per ATC)
Technical bid documents and compliance certificates
OEM authorization letters (if bidding as authorized dealer/partner)
Extended Deadline
14-Jan-2026, 10:00 am
Opening Date
14-Jan-2026, 10:30 am
Extended Deadline
07-Jan-2026, 10:00 am
Opening Date
07-Jan-2026, 10:30 am
Extended Deadline
03-Jan-2026, 10:00 am
Opening Date
03-Jan-2026, 10:30 am
Key insights about KERALA tender market
To bid, obtain the ATC document from the buyer, ensure OEM authorizations, prepare GST, PAN, and financials, and submit EMD as specified in the ATC. Ensure compliance with pressure gauge ranges (0-6 to 0-60 bar) and alcohol-filled thermometers with listed thermowell lengths. Review delivery terms and option clause carefully.
Submit GST certificate, PAN, experience certificates for similar supply, financial statements, EMD documents, technical bid and compliance certificates, and OEM authorization letters. Ensure all documents align with ATC requirements and tender terms for complete eligibility.
Gauges are 1 by 4 inch BSP M.S. Bourdon with ROOT VALVE in ranges 0-6 bar, 0-10 bar, 0-16 bar, and 0-60 bar. Thermometers are alcohol-filled with straight type, 30 mm to 160 mm thermowell variants, and temperature scales up to 100°C and 120°C.
Delivery starts after the original delivery order; extension is allowed under the option clause. Additional time equals (increased quantity ÷ original quantity) × original delivery period, with a minimum of 30 days. The purchaser may extend the duration up to the original delivery period on exercising the option.
The BOQ lists 10 items with the products specified (gauges and thermometers), but exact quantities are not disclosed in the available data. Bidders should rely on the ATC for final quantities and ensure flexibility for ±25% variation as per clause.
The tender references OEM authorizations and ATC documents; while specific standards are not listed in the data, bidders should seek conformity with marine instrumentation norms and ensure ISI/ISO certifications if specified in ATC, along with any organization-specific compliance.
Exact payment terms are not provided in the data. Bidders must review the ATC for milestone-based payments and security deposits. Ensure pricing accounts for potential quantity fluctuations up to 25% and extended delivery terms per the option clause.
Prepare a complete bid package including technical compliance, EMD, OEM authorizations, and financial documentation. Submit through the official portal per the ATC, ensuring all required documents and certificates are current and match the tender scope for 1 by 4 inch BSP gauges and alcohol-filled thermometers.
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS