Progress
Quantity
1
Bid Type
Two Packet Bid
Cattle And Dairy Development Division announces a tender for Bacterial and Somatic Cell Analyser (Q3) in HAVERI, KARNATAKA. Quantity: 1. Submission Deadline: 31-10-2025 19: 00: 00. Last date to apply is approaching fast!
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Bacterial and Somatic Cell Analyser (Q3)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
| Category | Specification | Requirement |
|---|---|---|
| Construction | Input Power Supply | 100-240 V, 50Hz |
| Functional Parameter | Technology Used | Flow Cytometry |
| Functional Parameter | Parameters | IBC, SCC |
| Functional Parameter | Sample Type | Cow Milk, Buffalo Milk, Mix Milk |
| Performance Parameter | Performance Range (IBC) (IBC/ml) (Min.) | 5000-10000 |
| Performance Parameter | Measuring range (SCC) (cells/ml) (Min.) | 0-5000 |
| Performance Parameter | Analysis time (IBC) (in Minute) | 7-10 |
| Performance Parameter | Working factor (IBC) | 100 |
| Performance Parameter | Repeatability (SCC) at 500000 cells/ml | CV < 3 % |
| Performance Parameter | Repeatability (SCC) at 300000 cells/ml | CV < 4 % |
| Performance Parameter | Performance Range (SCC) (cells/ml) (Max.) | 15000000-2000000 |
| Performance Parameter | Analysis capacity (Only IBC) (Samples/Hour) | 15 |
| Performance Parameter | Working factor (SCC) | 100 |
| Performance Parameter | Repeatability (IBC) at 10-50 IBC/?l | Sr <= 0.07 log relative |
| Performance Parameter | Accuracy (SCC) | < 10% relative mean difference form Direct Microscopic SCC |
| Performance Parameter | Measuring range (IBC) (IBC/ml) (Max.) | 15000000-20000000 |
| Performance Parameter | Sample Intake (Only IBC) (in ml) | 5-7 |
| Performance Parameter | Repeatability (IBC) at >200 IBC/?l | Sr <= 0.05 log relative |
| Performance Parameter | Performance Range (SCC) (cells/ml) (Min.) | 10000-15000 |
| Performance Parameter | Compatible Software for Documentation and Presentation | Yes |
| Performance Parameter | Performance Range (IBC) (IBC/ml) (Max.) | 5000000-10000000 |
| Performance Parameter | Analysis capacity (SCC and IBC) (Samples/Hour) | 10, 15 |
| Performance Parameter | Measuring range (SCC) (cells/ml) (Max.) | 10000000-15000000 |
| Performance Parameter | Measuring range (IBC) (IBC/ml) (Min.) | 4000-5000 |
| Performance Parameter | Sample Intake (Only SCC), ml | 2.0-2.5 |
| Performance Parameter | Repeatability (SCC) at 100000 cells/ml | CV < 6 % |
| Performance Parameter | Repeatability (IBC) at 51-200 IBC | Sr <= 0.06 log relative |
| Performance Parameter | Sample Intake (SCC and IBC) (in ml) | 7-9 |
| Installation & training | Supplier capable to supply appropriate Reagents and Consumables sample as and when required | Yes |
| Installation & training | Appropriate Reagents and Consumables sample for IBC (Approx) | 10000 |
| Installation & training | No. of days of training program | 2 |
| Installation & training | Appropriate Reagents and Consumables sample for SCC (Approx) | 10000 |
| Installation & training | No of people to be trained in training program | 5-10 |
| Installation & training | Spares and Preventive Maintainance kits and Accessories for routine operation | Yes |
| Installation & training | No of training sessions executed | 10 |
| Warranty & services | Ability of supplier to provide spares/consumables upto 10 years of supply(Separate purchases not included in this purchase) | Yes |
| Warranty & services | Warranty from date of installation(System & all other parts) in years | 1.0 |
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | ANALYTICAL TECHNOLOGIES LIMITED Under PMA | Make : ANALYTICAL Model : BSMC-3012 | 31-10-2025 16:43:05 | |
| 2 | INDIFOSS ANALYTICAL PRIVATE LIMITED Under PMA | Make : FOSS Model : BacSomatic | 31-10-2025 13:37:13 | |
| 3 | TARA INTERNATIONAL Under PMA | Make : Bentley Model : IBCm 3.0 | 31-10-2025 18:57:17 |
| Rank | Seller | Price | Item |
|---|---|---|---|
| L1 | INDIFOSS ANALYTICAL PRIVATE LIMITED Under PMA | Item Categories : Bacterial and Somatic Cell Analyser |
Please sign in or create an account to view contract details and download result documents.
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS