TenderDekho Logo
GEM

Bids are Invited For Gas Chromatography - Triple Quadrupole Mass Spectrometry (GC - MS - MS) in KARNAL, HARYANA

Bid Publish Date

07-Jul-2026, 10:11 am

Bid End Date

06-Aug-2026, 11:00 am

Progress

Issue07-Jul-2026, 10:11 am
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 11

Indian Council Of Agricultural Research (icar) invites bids for Gas Chromatography - Triple Quadrupole Mass Spectrometry (GC - MS - MS) (Q3) in KARNAL, HARYANA. Quantity: 1. Submission Deadline: 06-08-2026 11: 00: 00. Submit your proposal before the deadline.

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Gas Chromatography - Triple Quadrupole Mass Spectrometry (GC - MS - MS) (Q3)

Authority Records

MINISTRY OF AGRICULTURE AND FARMERS WELFAREAGRICULTURAL RESEARCH AND EDUCATION DEPARTMENTINDIAN COUNCIL OF AGRICULTURAL RESEARCH

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 5

GeM-Bidding-9546774.pdf

Main Document

Other Documents

OTHER

GeM Category Specification

GEM_CATEGORY_SPECIFICATION

Other Documents

OTHER

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Gas Chromatography - Triple Quadrupole Mass Spectrometry (GC - MS - MS)

Jai Narayan Vyas University Jodhpur

JODHPUR, RAJASTHAN

Posted: 31 March 2025
Closed: 15 April 2025
GEM

Gas Chromatography - Triple Quadrupole Mass Spectrometry (GC - MS - MS)

University Of Ladakh

KARGIL, JAMMU & KASHMIR

Posted: 11 March 2026
Closed: 24 March 2026
GEM

Gas Chromatography - Triple Quadrupole Mass Spectrometry (GC - MS - MS)

N/a

GANDHI NAGAR, GUJARAT

Posted: 18 February 2026
Closed: 18 March 2026
GEM

Gas Chromatography - Triple Quadrupole Mass Spectrometry (GC - MS - MS)

Uttar Pradesh State Institute Of Forensic Science

Posted: 13 November 2024
Closed: 25 November 2024
GEM

Gas Chromatography - Triple Quadrupole Mass Spectrometry (GC - MS - MS)

N/a

PARBHANI, MAHARASHTRA

Posted: 4 September 2025
Closed: 15 September 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
GAS CHROMATOGRAPH (GC) CONFIGURATION GC Detectors inclusive in the scope of supply Flame Ionization Detector (FID), Thermal Conductivity Detector (TCD or Hot Wire Detector), Electron Capture Detector (ECD), Nitrogen–Phosphorus Detector (NPD) / Flame Thermionic Detector (FTD), Flame Photometric Detector (FPD), Photo Ionization Detector (PID), Pulsed Flame Photometric Detector (PFPD)
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of FID in the System - inclusive in the scope of Supply 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of TCD in the System - inclusive in the scope of Supply 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of ECD in the System - inclusive in the scope of Supply 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of NPD/FTD in the System - inclusive in the scope of Supply 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of FPD in the System - inclusive in the scope of Supply 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of PID in the System - inclusive in the scope of Supply 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of PFPD in the System - inclusive in the scope of Supply 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION Number of Inlets GC can Simultaneously Support 1, 2, 3
GAS CHROMATOGRAPH (GC) CONFIGURATION Number of Detectors (Ports) GC can Simultaneously Support 1, 2, 3, 4
GAS CHROMATOGRAPH (GC) CONFIGURATION Number of Capillary Columns provided in GC - inclusive in the scope of Supply 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION Type of Capillary Column Polar, Non-Polar, Semi-Polar, NA
GAS CHROMATOGRAPH (GC) CONFIGURATION "GC Capillary Column Length 0, 30, 60, 100
PERFORMANCE "GC Detector Minimum Detection Level (MDL) < 1.4 pg C/s for FID, < 1.8 pg C/s for FID, < 3.0 pg C/s for FID < 400 pg/ml for TCD, < = 1 microgram/ml for TCD, < = 10 microgram/ml for TCD, < 4.5 fg /sec for ECD, < 5.5 fg /sec for ECD, < 0.1pg N /sec for NPD/FTD, < 0.03 pg P /sec for NPD/FTD, < 100 fg P /sec for FPD, <2.5 pg S /sec for FPD, <5 pg S /sec for FPD, < 45 fg P /sec for FPD
COLUMN OVEN (GAS CHROMATOGRAPH - GC) Maximum Operating Temperature (GC Oven) upto 400 deg. C, upto 450 deg. C Or higher
COLUMN OVEN (GAS CHROMATOGRAPH - GC) Number of Oven Ramps / Plateaus for Temperature programming 6/7 or more, 9/10 or more, 20/21 or more
PNEUMATIC CONTROL Number of Injection Ports 1, 2
PNEUMATIC CONTROL Maximum Injection Port heating Temperature upto 400 deg. C, upto 450 deg. C Or higher
PNEUMATIC CONTROL Pressure Range upto100 psi, upto 140 psi Or higher
PNEUMATIC CONTROL Pressure set point Resolution (±)(psi) 0.001, 0.01, 0.1 Or lower
PNEUMATIC CONTROL Type of Sample Injection Port Split, Splitless, split / Splitless, Programmable Temperature Vaporizer (PTV)
PNEUMATIC CONTROL Split Ratio 6000:1, 7000:1, 7500:1, NA
AUTO INJECTOR / AUTO SAMPLER Compatible Liquid Auto Sampler - inclusive in the scope of supply Yes, No
AUTO INJECTOR / AUTO SAMPLER Capacity of the Liquid Auto Sampler (Number of Vials) 0, 8, 100, 150 Or higher
AUTO INJECTOR / AUTO SAMPLER Number of Injection Ports in the Liquid Auto Sampler 0, 1, 2
AUTO INJECTOR / AUTO SAMPLER Number of Channels in the Liquid Auto Sampler 0, 2
AUTO INJECTOR / AUTO SAMPLER "Liquid Auto Sampler Features (Select applicable features Only)" Fully automated Liquid Auto Sampler, Injects with variable speed & varying syringe sizes, Operates through Software (Software inclusive in the scope of supply), NA
HEAD SPACE SAMPLER Compatible Head Space Sampler- inclusive in the scope of supply Yes, No
HEAD SPACE SAMPLER Capacity of the Head Space Sampler Carousel (number of Vials) 12 or better, NA
HEAD SPACE SAMPLER Head Space Sampler Temperature Range Upto 200 deg. C or better, NA
PYROLYZER SYSTEM Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply Yes, No
MASS SPECTROPHOTOMETER (MS-MS) SYSTEM Ionization modes Electron Ionization (EI), EI/PCI/NCI
MASS SPECTROPHOTOMETER (MS-MS) SYSTEM Detector Type Electron Multiplier, Triple-Axis, HED-EM
MASS SPECTROPHOTOMETER (MS-MS) SYSTEM Operating modes Full Scan Mode, Selective Ion Monitoring (SIM) Mode, Both Full Scan & SIM Modes, Selective /Multiple Reaction Monitoring (SRM/MRM)
PERFORMANCE OF THE MASS SPECTROPHOTOMETER (MS-MS) SYSTEM Sensitivity (S/N Ratio) in full scan 300:1, 1500:1 Or higher
PERFORMANCE OF THE MASS SPECTROPHOTOMETER (MS-MS) SYSTEM Sensitivity (S/N Ratio) in SRM/MRM 6000:1, 15000:1, 30000:1 Or higher
GENERIC Power Supply 230 V ± 10%, 415 V ± 10%
GENERIC Built-in Display Yes, No
GENERIC Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously Yes, No
GENERIC Back Flash - inclusive in the scope of supply Pre Column Back Flush, Post Column Back Flash, Mid Column Back Flash, NA
SALIENT FEATURES OF GC-MS-MS "Salient Featutes of GC-MS (Select applicable features Only)" Automatic leak testing/detection of Pneumatics, Direct setting of split flow rates and ratios, Flow sensor for control & storage of split ratio, Split and Septum Purge gases, Able to direct inject onto packed and wide-bore capillary columns, Oven power turns-off automatically when the lid/door is opened, Over Heat Protection, Display Unit with built-in Key Board, Controlled by External PC System, Programmable ion source temperature, System includes variety of auto tune algorithms to tune the instrument for maximum sensitivity or for specific target compounds, EI source is inert to active compounds and programmable, EI Source have a dual filament design with automatic selection of other filament if one fails during analysis;, NA, Off-axis detection system for better removal of neutrals, Electron Impact ion source with dual filaments temperature up to 350 °C, Emission current should be able to set up to 300 µA or better, MRM/SRM Transitions should be 800 transitions/sec, Buyer specific columns - DB-fame /equivalent column 60 m x 0.25 mm id x 0.25 micron- 2 nos , DB-1 /equivalent column 60 m x 0.25 mm id x 0.25 micron- 1 nos, Instrument detection limit sensitivity of < 2 fg during installation using 5 fg of OFN with 1 ul injection with Auto sampler
LIBERARIES Libraries for GC-MS NIST Library for MS - Licensed version - 2017 or latest, MRM data base Library, Library for Pesticides, Library for Environmental, Library for Forensic, Wiley Library, NA
SOFTWARE "Software Features (Select Applicable Features only)" Compatible with Windows 7 or higher version operating system, Seamless integration & control of all the GC parameters, Interface with Multiple GCs through the comprehensive real-time monitoring and diagnostic software, Real time notification via advisories and indicators, Counters, Chromatographic attributes, Instrument diagnostics, Access to maintenance information, Access to maintenance, run and event logs, Retention Time - Locking module for analyzing target compounds in complex matrices
ACCESSORIES Gas Supply inclusive in the scope of supply Nitrogen, Hydrogen, Argon, Helium, Zero Air, Not offered
ACCESSORIES Number of Cyliners of each type supplied - inclusive in the scope of supply 0, 1, 2
ACCESSORIES Gas cylinders certified by PESO Yes, NA for Gas Cylinder not offered
ACCESSORIES Regulator - inclusive in the scope of supply Dual Stage Regulator, NA
ACCESSORIES "Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" Gas purification panel for all Gases with moisture trap, Hydrocarbon trap & Oxygen trap, Syringe for manual injection x 05 nos, Auto Sampler Vials x 1000 vials with screw cap, Graphite ferrules x 10 nos, Vessel ferrules x 10 nos, Septa for injector x 100 nos, Inlet liner for splitles x 4 nos, Inlet liner for split x 4 nos, O-rings x 10 nos. of each type, Column Cutter x 2 nos, Gas tube Cutter x 2 nos, Tool Kit x 1 no., User / Technical / Maintenance Manual, Standard Samples - NIST / IPL Traceable, Direct Injection Port, Splitter, Multishot Pyrolyser, Singleshot Pyrolyser, Syringe for Auto Sampler injection x 10 nos, EI filaments x 5 nos, NA
DESKTOP WORKSTATION Desktop workstation Suitable to GC-MS - inclusive in the scope of supply Yes, No
DESKTOP WORKSTATION Graphics Card Memory Size 0, 1, 2, 4
ONLINE UPS UPS Provided in the Scope of Supply Yes, No
ONLINE UPS Rating of online UPS(KVA) 5.0 KVA, 7.5 KVA, 10 KVA, NA
ONLINE UPS Backup time of online UPS 0, 60, 90, 120
INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING Warranty on equipment 1, 2, 3, 5
INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING Number of days onsite training provided 3, 5, 7, 10
CERTIFICATION / TEST REPORT "Availability of UL/CE Certificate as per EN 61010- 1:2010 Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" Yes, No
CERTIFICATION / TEST REPORT Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use Yes, No
CERTIFICATION / TEST REPORT Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification Yes, No

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria

7

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

5 found
Urgent

Gas Chromatography - Triple Quadrupole Mass Spectrometry (GC - MS - MS)

Skuastkashmir

📍 SRINAGAR, JAMMU & KASHMIR

EMD: ₹5.0 L
⏰ Deadline: 2 days left
🛒 Type: Goods
View GEM
Urgent

LIQUID CHROMATOGRAPHY MASS SPECTROSCOPY TRIPLE TANDEM QUADRUPOLE (LCMS/MS SYSTEM)

All India Institute Of Medical Sciences (aiims)

📍 KAMRUP, ASSAM

EMD: ₹5.0 L
⏰ Deadline: 3 days left
🛒 Type: Goods
View GEM

LC-MS (Liquid chromatography Mass spectrometer system with advanced triple quad with UHPLC along wi

Jammu And Kashmir Police

📍 SRINAGAR, JAMMU & KASHMIR

EMD: ₹8.4 L
⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM

Procurement Opportunity: PUR/IICT/17039/227/26-27/EQPT

Council of Scientific and Industrial Research

EMD: ₹1.5 L
⏰ Deadline: 4 weeks left
🛒 Type: Goods
View EPROCURE
Urgent

Gas Chromatography

Indian Institute Of Technology (iit)

EMD: ₹1.1 L
⏰ Deadline: 6 days left
🛒 Type: Goods
View GEM