High Performance Liquid Chromatography (HPLC) System
Health Services
AIZAWL, MIZORAM
Progress
Quantity
2
Category
Anaesthesia Workstation (V2)
Bid Type
Two Packet Bid
Iocl Bongaigaon Refinery invites bids for Anaesthesia Workstation (V2) (Q2), High Performance Liquid Chromatography (HPLC) System (Q3) in BONGAIGAON, ASSAM. Quantity: 2. Submission Deadline: 13-02-2026 16: 00: 00. Submit your proposal before the deadline.
Main Document
OTHER
CATALOG Specification
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Health Services
AIZAWL, MIZORAM
Chhattarpur Nagar Panchayat
PALAMAU, JHARKHAND
N/a
Rural Development Department
PURNIA, BIHAR
Rural Development Department
PURNIA, BIHAR
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Anesthesia Workstation |
| GENERAL | Components of Anesthesia workstation | Anesthesia machine , Inbuilt ventilator , vaporisor , Gas delivery system , Multi para monitor |
| Gas Delivery System | Availability of Pin index yokes for gases | Oxygen and Nitrous oxide |
| Gas Delivery System | Number of Yokes, Oxygen | 1 |
| Gas Delivery System | Number of Yokes, N2O | 1 |
| Gas Delivery System | NIST /DISS Inlet pipeline with Hoses for O2, N2O and Air | Yes |
| Gas Delivery System | Availability of flow meters for O2, N2O and air | Yes |
| Gas Delivery System | Type of Flowmeter | Electronic |
| Gas Delivery System | Mode of gas mixing | Pneumatic |
| Gas Delivery System | Availability of pressure gauges for cylinder and pipelines in anesthesia workstation | Yes |
| Gas Delivery System | Availability of audible and visual oxygen failure alarms | Yes |
| Gas Delivery System | Minimum emergency oxygen flow (in liter per minute) | 35 - 70 |
| Gas Delivery System | Type of hypoxic guard with automatic cutoff of N2O | Mechanical |
| Gas Delivery System | Minimum 25% O2 across all Oxygen - Nitrous Oxide Mixture | Yes |
| Gas Delivery System | Auxillary Oxygen Flowmeter | Yes |
| Gas Delivery System | Auxillary Common Gas outlet for use in open circuit | Yes |
| Vaporizer | Number of quick mount type vaporizer for easy interchangeability at a time | 2 |
| Vaporizer | Number of selectatec back bar | 1 |
| Vaporizer | Facility of interlock for vaporizer | Yes |
| Vaporizer | Minimum agent capacity for free volatile anesthetic agent (in ml) | 225 ml |
| Vaporizer | Sensor connection shall be internal to prevent disconnection | Yes |
| Vaporizer | Vaporizer compatible to gases | Sevoflurane, Isoflurane |
| Vaporizer | The vaporizer design should be maintenance free | Yes |
| Vaporizer | Vaporizer calibration requirement | After every 5 years |
| Vaporizer | Should have a drug specific Filling arrangement | Yes |
| Breathing System | Breathing system should have fresh gas de-coupled / compensation , closed circle absorber system | Yes |
| Breathing System | Range of pressure relief valve (in mbar) of breathing system | 5 to 75 |
| Breathing System | Number of steps in change over from Mechanical / Spontaneous to bag ventilation | Single step |
| Breathing System | Number of reusable autoclavable closed silicone circuit supplied | 2 Nos for adult |
| Breathing System | Number of Disposable closed circuits - Adult | NA |
| Breathing System | Number of Disposable closed circuits - Pediatric | NA |
| Breathing System | Number of Disposable closed circuits - Neonatal | NA |
| Breathing System | Number of bains circuit (adult) supplied with workstation | 10 |
| Breathing System | Number of Jackson Rees circuit for pediatric patients supplied with workstation | 10 |
| Breathing System | Volume capacity of breathing system (in liters) | 1.5 or more |
| Breathing System | Reusable flow sensors covered in warranty | No |
| Breathing System | Dual flow sensor at inspiratory and expiratory port | No |
| Breathing System | Breathing system should have leak and compliance test | Yes |
| Breathing System | Breathing system should be autoclavable | No |
| Breathing System | Facility of CO2 Bypass | No |
| Anesthesia Ventilator | Available modes of operating ventilator | Manual/spontaneous, Volume controlled, Pressure controlled, SIMV/PCV, SIMV/VCV, CMV |
| Anesthesia Ventilator | Ventilator should be capable to pressure support | No |
| Anesthesia Ventilator | Ventilator should be capable to dual mode of ventilation | No |
| Anesthesia Ventilator | Integrated ventilator not require bellows to be change for adults and infants | Yes |
| Anesthesia Ventilator | Tidal volume of ventilator (in ml) | 10 to 1400 ml |
| Anesthesia Ventilator | PEEP of ventilator in mbar | 0 to 20 mbar |
| Anesthesia Ventilator | Breathing frequency in BPM | 4 to 60 BPM |
| Anesthesia Ventilator | Inspiratory pause percentage of Ti | 0 - 50% |
| Anesthesia Ventilator | Screen size of Ventilator monitor in inches | 6 to 10, 10.1 to 15, 15 .1 and more Or higher |
| Anesthesia Ventilator | Integrated ventilator shall be able to provide facility to monitor FiO2, dual agent, CO2, Automatic identification of agents, Minimal Alveolar Concentration (MAC) Value | No |
| Anesthesia Ventilator | Integrated ventilator shall be able to provide facility to monitor expired O2 (EtO2) | No |
| Anesthesia Ventilator | Flow Trigger Sensitivity | Adult |
| Monitor | Type of monitor LCD/LED/TFT | NA (If monitor not provided) |
| Monitor | Size of monitor in inches | 12 to 15, 15.1 to 18, 18.1 and more Or higher |
| Monitor | Monitor should not require lengthy start up procedure or calibration for display of parameters | NA (If monitor not provided) |
| Monitor | The graphical and numerical trend with split screen duration | NA (If monitor not provided) |
| Monitor | Patient multipara monitor shall be able to display parameters | NA(If monitor not provided) |
| Monitor | Capnography to be displayed | No |
| Monitor | IBP1 and IBP2 to be displayed | No |
| Monitor | CO (cardiac output) to be displayed | No |
| Monitor | Anesthesia Gas Monitoring (AGM) | Yes |
| Monitor | BIS/ENTROPY to be displayed | No |
| Monitor | Neuro Muscular Transmission(NMT) to be displayed | No |
| Monitor | ECG monitoring with standard lead configuration, I,II,III, avL, avF&V filters so that it is protected against defibrillator, electro surgery potentials, arrhythmia analysis and ST segment analysis with trends | NA (If monitor not provided) |
| Monitor | NIBP should be determine with oscillometric method, should read systolic, diastolic and mean arterial pressure and pulse rate | NA (If monitor not provided) |
| Monitor | Pulse oximetery with sensors suitable for adults, pediatric & neonate | NA (If monitor not provided) |
| Monitor | ETCO2 measurement should be by infra –red absorption technique,measuring mode should be side streamor main stream and response time should be less than 3 seconds | NA (If monitor not provided) |
| Monitor | Monitor should be able to measure and display all parameters in single screen | Yes |
| Monitor | Monitor should be provided from the same OEM | NA (If monitor not provided) |
| Alarms | Alarms | Tidal Volume, Minute Volume, Airway Pressure Low and High, Inspiratory Oxygen concentration, Audio power supply fail alarm, Fail to cycle warning (apnea). |
| Alarms | Alarms shall be adjustable to high / low limits with audio and visual alarms | Yes |
| Power supply | Length of main cable in meter with power socket of standard indian make to be provided | ≥5 |
| Power supply | Inbuilt battery backup for monitor in Mins | 30, 60, 120, 180, 240, 300, 360 Or higher |
| Power supply | Power supply | 220-240V AC, 50 Hz single phase |
| Additional Accessories | Transparent re-usable silicon face mask size 0,1, 2, 3, 4 & 5 | 2 each |
| Additional Accessories | Breathing bag capacity - 2 Each | 500 ml |
| Additional Accessories | 3/5 ECG lead | NA (If monitor not provided) |
| Additional Accessories | Nasopharyngeal/rectal and skin Temperature probes should be Provided | NA(If monitor not provided) |
| Additional Accessories | NIBP Reusable Large adult, Reusable small adult cuffs, Reusable Pediatric cuff | NA (If monitor not provided) |
| Additional Accessories | ETCO2 sample line | 10 |
| Additional Accessories | Pressure regulator with 3 meter high Pressure tubing(1 for oxygen and 1 for Nitrous oxide) | No |
| Additional Accessories | Provision for laryngscopes | Not Provided |
| Additional Accessories | Number of Reusable patient circuits | 1 No. Adult |
| Additional Accessories | SpO? sensor with cable provided | NA (If monitor not provided) |
| Additional Accessories | Reusable IBP interface cables | Not provided |
| Additional Accessories | Disposable IBP transducers | Not provided |
| Additional Accessories | BIS sensors | Not provided |
| Additional Accessories | Accessories for wall mounting | NA (If trolley mounting) |
| ADDITIONAL PARAMETERS | Type of mounting for the Anesthesia workstation | Trolley Mounting |
| ADDITIONAL PARAMETERS | Material used for Anesthesia workstation | Epoxy powder painted steel |
| ADDITIONAL PARAMETERS | Mode of integrated scavenging system with pressure relief valve | Passive |
| ADDITIONAL PARAMETERS | Minimum Battery backup for anesthesia workstation | 45 Minute |
| ADDITIONAL PARAMETERS | Facility of manual ventilation in case of electricity and battery failure | Yes |
| ADDITIONAL PARAMETERS | Facility of gas and agent delivery in case of electricity and battery failure | Yes |
| ADDITIONAL PARAMETERS | All the components likes anesthesia machine, integrated ventilator, vaporizer from the same manufacturer | Yes |
| ADDITIONAL PARAMETERS | The workstation should have one or more drawers to keep accessories, good mobility, anti-static caster wheels with locking facility & conveniently placed handles for easy movement of the machine | Yes |
| ADDITIONAL PARAMETERS | All software updates should be provided free of cost during Warranty period | Yes |
| ADDITIONAL PARAMETERS | The anesthesia machine can be used safely up to 1000 gauss line while being used with MRI | No |
| ADDITIONAL PARAMETERS | Pressure relief | 5 to 70 cm H20 |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Certification for manufacturing unit | ISO:13485 (Latest) |
| CERTIFICATIONS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Electrical Protection certification | IEC-60601-1-1 or equivalent BIS |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| WARRANTY | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3, 4, 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
N/a
📍 Raigarh, CHHATTISGARH
N/a
Oil And Natural Gas Corporation Limited
📍 BHARUCH, GUJARAT
Oil And Natural Gas Corporation Limited
📍 BHARUCH, GUJARAT
Indian Institute Of Technology (iit)
📍 MANDI, HIMACHAL PRADESH
Sign up now to access all documents
Main Document
OTHER
CATALOG Specification
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS