Progress
Public procurement opportunity for Oil And Natural Gas Corporation Limited Multi Gas Detector (V1) (Q2) in BHARUCH, GUJARAT. Quantity: 5 issued by. Submission Deadline: 02-09-2026 15: 00: 00. View full details and respond.
Quantity
5
Bid Type
Single Packet Bid
Bid Validity
60 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
3 Days
EMD Required
No
MII Purchase Preference
No
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Warranty Period
2 years
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Multi Gas Detector (V1) (Q2)
Payment Timelines
Payments shall be made to the Seller within 10 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
30
Delivery Locations
1
Delivery Cities
Bharuch
Delivery Pincodes
392130
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Sajan Chacko | 392130,C2C3 Plant Dahej, ONGC, Plot No.7/D , Dahej SEZ Ph-II, Taluka Vagra, District- Bharuch. | Bharuch | Gujarat | 392130 | 5 | 30 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Extended Deadline
02-Sep-2026, 9:30 am
Opening Date
02-Sep-2026, 10:00 am
Discover companies most likely to bid on this tender
Experience Criteria
Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| TYPE/APPLICATION/TECHNOLOGY | Type | Portable /Handheld |
| TYPE/APPLICATION/TECHNOLOGY | Detactable Gases | Combustible Gas-Lower Explosive Limit(LEL), Oxygen(O2), Hydrosulfide(H2S), Carbon Monooxide(CO), Ammonia(NH3), Sulfur dioxide(SO2), Chlorine(CI2), Methane (CH4) |
| TYPE/APPLICATION/TECHNOLOGY | Gases for which Preset value to be set by user | Lower Explosive Limit(LEL), Oxygen(O2), Hydrosulfide(H2S), Carbon Monooxide(CO), Sulfur dioxide(SO2) |
| AREA OF USE - HAZARDOUS AREA CLASSIFICATION | Hazardous area classification standard | IEC 60079 (latest) |
| AREA OF USE - HAZARDOUS AREA CLASSIFICATION | Area of use - Hazardous area classification | Intrinsically safe for use in hazardous area classification conforming to Class I, Division I, Group A, B, C & D or Zone - 0, Group-IIA, IIB & IIC |
| MEASUREMENT OF Combustible Gas- Lower Explosive Limit(LEL) | Measurment Range of Combustible gas(LEL) | 0 -100 % |
| MEASUREMENT OF Combustible Gas- Lower Explosive Limit(LEL) | Resolution of the Combustible gas(LEL) measurement | 1 % |
| MEASUREMENT OF OXYGEN(O2) | Measurment Range of Oxygen(O2) gas concentration | 0 -25 % |
| MEASUREMENT OF OXYGEN(O2) | Resolution of the Oxygen(O2) measurement | 0.1 |
| MEASUREMENT OF HYDROGEN SULFIDE (H2S) | Measurment Range of HYDROGEN SULFIDE (H2S) gas concentration | 0 -100 ppm |
| MEASUREMENT OF HYDROGEN SULFIDE (H2S) | Resolution of the HYDROGEN SULFIDE (H2S) measurement | 1 ppm |
| MEASUREMENT OF SELECTABLE GAS(CO/NH3/SO2/CL2 etc) | Measurment Range of Selectable Gas(CO/NH3/SO2/Cl2/CH4/CO2) | 0 -500 ppm |
| MEASUREMENT OF SELECTABLE GAS(CO/NH3/SO2/CL2 etc) | Resolution of the Range of Selectable Gas(CO/NH3/SO2/Cl2/CH4/CO2) measurement | 0.1 ppm |
| PERFORMANCE PARAMETER OF THE DETECTOR | Accuracy | +/- 2 % of measured value |
| PERFORMANCE PARAMETER OF THE DETECTOR | Response time to reach to 90% of measured value(with Sampling pumping house) | 25.0, 30.0 |
| SAMPLING PUMP | Sampling Pump | Fitted with Motorized Pump with Audio and visual low flow alarm |
| SAMPLING PUMP | Remote Sampling Accessories in the scope of Supply | Minimum 120 feet long sampling hose and sampling probe equipped ; Suitable Filter |
| POWER SOURCE | Power Source | Rechargeable Batteries;, Alkaline Batteries (Non-Rechargeable);, Mains (230 ± 10 Volts / 50 Hz AC) |
| POWER SOURCE | Suitable Battery Charger operable with 230 V + 5%, 50 Hz AC inclusive in the scope of supply | Yes Or higher |
| GENERIC | Display | Self-illuminating back-light digital display |
| GENERIC | Enclsoure Protection rating | IP 67, IP 68 Or higher |
| GENERIC | Weight(Including Battery & Sampling pump | < 500 gram(Handheld/Portable) |
| FEATURES | Display Features | Simultaneous Display for all four gases, Simultaneous readout for each gas monitored in ppm, %, LEL as aplicable |
| FEATURES | Audio Visual Alarm | Visual 360° LED, > 108 dB in a distance of 1m(30ft);, Audible 360 DEGREE, configurable alarm patterns frequencies and volumes |
| ACCESSORIES | Accessories in the scope of supply | Calibration cup/adaptor/calibration tubing to facilitate calibration locally, Operation Manual, Carrying case |
| WARRANTY/SERVICE | Warranty on Equipment | 24 Or higher |
| WARRANTY/SERVICE | Warranty on Sensor | 24 Or higher |
| OPERATING ENVIRONMENT | Minimum Operating Temperature | -20.0 Or lower |
| OPERATING ENVIRONMENT | Maximum Operating Temperature | 50.0 Or higher |
| TEST REPORT | Agree to provide all relevant documents Test Reports/supporting document /reports etc to the buyer at the time of bidding or on demand | Yes |