TenderDekho Logo
GEM

Invitation to Bid - Power Generator - DG Set (up to 900 KVA)

Bid Publish Date

26-Feb-2026, 7:24 pm

Bid End Date

19-Mar-2026, 8:00 pm

Progress

Issue26-Feb-2026, 7:24 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

2

Bid Type

Single Packet Bid

Categories 4

A tender has been published for Bharat Petroleum Corporation Ltd Power Generator - DG Set (up to 900 KVA) (Q2). Quantity: 2 by. Submission Deadline: 19-03-2026 20: 00: 00. Check eligibility and apply.

Documents 6

GeM-Bidding-9052514.pdf

Main Document

Other Documents

OTHER

Other Documents

OTHER

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Gujarat Forests And Environment Department DG Set Tender Bhavnagar 900 KVA 2025

N/a

BHAVNAGAR, GUJARAT

Posted: 18 December 2025
Closed: 29 December 2025
GEM

Directorate Of Collegiate Education Kerala 900 KVA DG Set Tender ISO Certified 2025

Directorate Of Collegiate Education

KOTTAYAM, KERALA

Posted: 23 December 2025
Closed: 3 January 2026
GEM

Power Generator - DG Set (up to 900 KVA)

N/a

AMRAVATI, MAHARASHTRA

Posted: 2 December 2025
Closed: 12 December 2025
GEM

Power Generator - DG Set (up to 900 KVA)

Central Water Commission (cwc)

KAMRUP, ASSAM

Posted: 11 November 2025
Closed: 26 November 2025
GEM

Power Generator - DG Set (up to 900 KVA)

Nhpc Limited

EAST SIANG, ARUNACHAL PRADESH

Posted: 15 February 2025
Closed: 15 March 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Power Generator INSTALLATION CONFIGURATIONS Power Generator installation configurations as defined in CPWD General Specifications for Electrical works - Part VII (DG Set) Fixed (Power Generators are permanently installed)"
OUTPUT CAPACITY RATING/ PHASE Nominal Rated Capacity (kVA) 62.5
OUTPUT CAPACITY RATING/ PHASE No of Phase (Single Phase-3-5kVA) (Single Phase or Three Phase-5 & 7-5, 10,15, 20, 25, 30 & 40 kVA) (Three Phase-50 to 900 kVA) Three Phase
ENGINE Rated Engine Power (kWm) 100 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator + Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience, 110 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience Or higher
ENGINE Type of governer Mechanical, Electronic Or higher
ENGINE Rated RPM of Engine (RPM) 1500
ENGINE Fuel High Speed Diesel (HSD)
ALTERNATOR Voltage Regulation Grade VG 3 Or higher
CONTROL PANEL Control Panel AMF Control Panel
TRAILER Trailer NA for Fixed/Skid Mounted Power Generator
TRAILER Pay load of the Trailer 0, 500, 1000, 2000 Or higher
SCOPE OF INSTALLATION Installation with installation - inclusive in the scope of supply Or higher
SCOPE OF INSTALLATION Scope of installation for Diesel Generating Set when offered by the vendor - inclusive in the scope of supply(Part-1) a) Installation of Power Generator when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation work of Power Generator and its constituent parts shall be generally conforming to CPWD General Specification for Electrical Works, Part - VII - latest. b) Foundation shall be constructed by the seller. Foundation shall be of PCC type with the ratio of 4:2:1. The length and breadth of the foundation shall be 300 mm more from the respective length and breadth of the Power Generator. The height of the foundation shall be 400 mm, i.e., 200 mm below and 200 mm above the ground level. All the materials / labour required for foundation work shall be supplied by the seller.
WARRANTY/SERVICES Warranty on Complete power genertor/DG Set 24, 36 Or higher
WARRANTY/SERVICES Number of preventive maintenance visits offered in an year during warranty period (Supply of all consumables is the buyer's responsibilty)* 2
TEST REPORTS Test report Available for (Test/approval) Type Approval Certificate for the specified rating of the Power Generator from any of the designated agency authorized by CPCB, COP Certificate for engine, Type test report for Alternator as per IS:13364 (Part-1) latest / IS:13364 (Part-2) latest to prove conformity to the specifications

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

OEM Authorization Certificate

5

OEM Annual Turnover

6

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

7

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer