Fully Automated Nephelometer
N/a
LUCKNOW, UTTAR PRADESH
Progress
Quantity
1
Bid Type
Single Packet Bid
Southern Railway invites bids for Fully Automated Nephelometer (Q2) in PALAKKAD, KERALA. Quantity: 1. Submission Deadline: 06-06-2026 14: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Fully Automated Nephelometer (Q2)
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
LUCKNOW, UTTAR PRADESH
All India Institute Of Medical Sciences (aiims)
N/a
PONDICHERRY, PUDUCHERRY
Employees State Insurance Corporation (esic)
KOLLAM, KERALA
Employees State Insurance Corporation (esic)
GULBARGA, KARNATAKA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Fully Automated Nephelometer |
| PRODUCT INFORMATION | Working Principle | Nephelometry |
| PRODUCT INFORMATION | Analyzing Modes | Rate Nephelometry |
| PRODUCT INFORMATION | Type of tests | IgA, Total IgG, IgM, Haptoglobin, Ceruloplasmin, ASO, RF, CRP, Ultra Sensitive CRP, C3, C4, Apo A1, Apo B, Urine MicroAlbumin, IgE, k Free Light Chain, λ Free Light Chain, Ferritin, LP(a) |
| PRODUCT INFORMATION | Minimum throughput | >=20 tests per hour, >=60 tests per hour, >=100 tests per hour Or higher |
| PRODUCT INFORMATION | Generating Levy- Jennings plots, from the stored data for efficient quality control | Yes |
| PRODUCT INFORMATION | Samples loaded in | Primary tubes |
| PRODUCT INFORMATION | Continuous loading | Yes |
| PRODUCT INFORMATION | Display | LED/LCD |
| PRODUCT INFORMATION | Touch screen interface | Yes |
| PRODUCT INFORMATION | Printer | Inbuilt printer |
| PRODUCT INFORMATION | Temperature control mechanism | Dry heater |
| PRODUCT INFORMATION | Reagent type | Single test cartridges with barcode for test identification |
| PRODUCT INFORMATION | Calibration | Smart Card Calibration |
| PRODUCT INFORMATION | Bidirectional host interface to connect with LIMS/HIS | Yes |
| PRODUCT INFORMATION | Storage of calibration curves for different reagents | Yes |
| PRODUCT INFORMATION | Reagents/Catridges to be supplied with the machine | IgA |
| PRODUCT INFORMATION | Supply necessary pre-requisites and startup kits, free of cost with required reagents calibrators and controls for the selected tests, as per the mentioned quantity for each test | 1 |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Certification for manufacturing unit | ISO:13485 (Latest) |
| CERTIFICATIONS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | Electrical Safety | IEC 60601-1-2 or Equivalent BIS |
| MISCELLANEOUS REQUIREMENTS | OEM/Reseller shall ensure uninterrupted availability of all spares, consumables and reagents for atleast 10 years | Yes |
| MISCELLANEOUS REQUIREMENTS | Availability of toll free facility for technical support maintened by OEM or authorized agencies | Yes |
| MISCELLANEOUS REQUIREMENTS | User/Technical/Maintenance manuals to be provided in English in hard and soft copy | Yes |
| MISCELLANEOUS REQUIREMENTS | Details of equipments and procedures required for local calibration and routine maintenance to be provided and advanced maintenance task documentation also to be furnished | Yes |
| MISCELLANEOUS REQUIREMENTS | Supplier to perform installation, safety and operation checks before handover | Yes |
| MISCELLANEOUS REQUIREMENTS | Training of users in operation and basic maintenance shall be provided | Yes |
| MISCELLANEOUS REQUIREMENTS | Contact details of manufacturer, supplier and local service agent to be provided | Yes |
| MISCELLANEOUS REQUIREMENTS | Certificate of calibration from the manufacturer | Yes |
| MISCELLANEOUS REQUIREMENTS | Supplier to provide the reagents/cartridges required to complete the installation, training and handover | Yes |
| WARRANTY | Warranty (Years) | 3, 5 Or higher |
Discover companies most likely to bid on this tender
Past Performance
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Dg Armed Forces Medical Service
All India Institute Of Medical Sciences (aiims)
📍 JODHPUR, RAJASTHAN
National Institute Of Mental Health And Neuro Sciences (nimhans)
📍 BANGALORE, KARNATAKA
Hll Infra Tech Services Limited
📍 NEW DELHI, DELHI
N/a
📍 VADODARA, GUJARAT
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS