C73340001918Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type
Bharat Electronics Limited (bel)
GHAZIABAD, UTTAR PRADESH
Bid Publish Date
28-Feb-2025, 4:02 pm
Bid End Date
11-Mar-2025, 9:00 am
Location
Progress
RAQuantity
7857
Bharat Electronics Limited (bel) invites bids for C73340001918Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type in GHAZIABAD, UTTAR PRADESH. Quantity: 7857. Submission Deadline: 11-03-2025 09: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Bharat Electronics Limited (bel)
GHAZIABAD, UTTAR PRADESH
Director General Of National Cadet Corps (dgncc)
LUCKNOW, UTTAR PRADESH
Bharat Electronics Limited (bel)
GHAZIABAD, UTTAR PRADESH
N/A
BASTI, UTTAR PRADESH
State Bank Of India (sbi)
DIMAPUR, NAGALAND
Tender Results
Loading results...
C73340001918Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure II-A
Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure II-A
C73340001724 Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure II-A
Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure II-A
C73340001821 Supply of Cassette AC four way capacity 4 TR rating Inverter type rotary scroll compressor aircooled condensing unit with copper cooling coil refer annexure II-A
Supply of Cassette AC four way capacity 4 TR rating Inverter type rotary scroll compressor aircooled condensing unit with copper cooling coil refer annexure II-A
100000000001Supply of suitable size refrigerant grade copper piping for 2or2point5or3or 4TR Cassette ACorSplit AC unit Refer annexureII-A
Supply of suitable size refrigerant grade copper piping for 2or2point5or3or 4TR Cassette ACorSplit AC unit Refer annexureII-A
100000000002Providing flexible PVC Duct hose Covering pipeof size 60 mm suitable for exposed refrigerant pipes for cassttte AC units refer anexure II-A
Providing flexible PVC Duct hose Covering pipeof size 60 mm suitable for exposed refrigerant pipes for cassttte AC units refer anexure II-A
100000000003 ProvidingcPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for refer annexureII-A
ProvidingcPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for refer annexureII-A
100000000004 Providing cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexureII-A
Providing cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexureII-A
100000000005 Supply of rain proof outdoor duty as per IP-66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter digital ammeter indication lamps refer annexureII-A
Supply of rain proof outdoor duty as per IP-66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter digital ammeter indication lamps refer annexureII-A
100000000006 Supply of following size LT power cable with Copper conductor XLPEorPVC as directed by EIC 4 core - 4 sqmm refer annexureII-A
Supply of following size LT power cable with Copper conductor XLPEorPVC as directed by EIC 4 core - 4 sqmm refer annexureII-A
100000000007 Supply of following size LT power cable with Copper conductor XLPEorPVC as directed by EIC 4 core - 6 sqmm refer annexureII-A
Supply of following size LT power cable with Copper conductor XLPEorPVC as directed by EIC 4 core - 6 sqmm refer annexureII-A
100000000008 Supply of following size LT power cable with Copper conductor laying of the same in by EIC 4core - 25 sqmm refer annexure-II-A
Supply of following size LT power cable with Copper conductor laying of the same in by EIC 4core - 25 sqmm refer annexure-II-A
100000000009Supply of following size LT power cable with Copper conductor as directed by EIC 4core - 16 sqmm refer annexure-II-A
Supply of following size LT power cable with Copper conductor as directed by EIC 4core - 16 sqmm refer annexure-II-A
100000000010 Supply of Copper cable of size 4core - 2point5 sqmm for communication refer annexure II-A
Supply of Copper cable of size 4core - 2point5 sqmm for communication refer annexure-II-A
100000000011 Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-A
Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-A
100000000012Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-A
Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-A
100000000013Installation testing and commissioning of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotaryorscroll compressor aircooled refer annexure-II-B
Installation testing and commissioning of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotaryorscroll compressor aircooled refer annexure-II-B
100000000014Installationtesting and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type refer annexure-II-B
Installationtesting and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type refer annexure-II-B
100000000015 Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor units refer annexure-II-B
Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor units refer annexure-II-B
100000000016 Erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexure-II-B
Erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexure-II-B
100000000017Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable refer annexure-II-B
Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable refer annexure-II-B
100000000018 Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexure-II-B
Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexure-II-B
100000000019 Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-II-B
Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-II-B
100000000020 Erection testing and commissioning of rain proof outdoor duty as per IP-66 Electrical control panel annexure-II-B
Erection testing and commissioning of rain proof outdoor duty as per IP-66 Electrical control panel annexure-II-B
100000000021 Laying of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed armoured extruded PVC oas directed by EIC 4 core - 4 sqmm refer annexure-II-B
Laying of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed armoured extruded PVC oas directed by EIC 4 core - 4 sqmm refer annexure-II-B
100000000022 Laying of following size LT power cable with Copper conductor XLPEorPVC insulation as directed by EIC 4 core - 6 sqmm refer annexure-II-B
Laying of following size LT power cable with Copper conductor XLPEorPVC insulation as directed by EIC 4 core - 6 sqmm refer annexure-II-B
100000000023Laying of following size LT power cable with Copper conductor as directed by EIC 4 core - 25 sqmm refer annexure-II-B
Laying of following size LT power cable with Copper conductor as directed by EIC 4 core - 25 sqmm refer annexure-II-B
100000000024Laying of following size LT power cable with Copper conductor XLPEorPVCas directed by EIC 4 core - 16 sqmm refer annexure-II-B
Laying of following size LT power cable with Copper conductor XLPEorPVCas directed by EIC 4 core - 16 sqmm refer annexure-II-B
100000000025Laying of Copper cable of size 4 core - 2point5 sqmm for communication refer annexure-II-B
Laying of Copper cable of size 4 core - 2point5 sqmm for communication refer annexure-II-B
100000000026Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-B
Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-B
100000000027Installing of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-B
Installing of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-B
100000000028Dismantling and shifting of existing Cassette AC 46 nos and VRV outdoor units of capacity 198 Hp refer annexure II-B
Dismantling and shifting of existing Cassette AC 46 nos and VRV outdoor units of capacity 198 Hp refer annexure-II-B
C73340100470Supply of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexureIII-A
Supply of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexureIII-A
C73340001724Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexureIII-A
Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexureIII-A
C73340001821Supply of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil fan motor refer annexureIII-A
Supply of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil fan motor refer annexureIII-A
100000000029Supply of suitable size refrigerant grade copper piping between indoor and outdoor units for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexureIII-A
Supply of suitable size refrigerant grade copper piping between indoor and outdoor units for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexureIII-A
100000000030Providing of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling cassttte AC units refer annexureIII-A
Providing of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling cassttte AC units refer annexureIII-A
100000000031Providing of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units to refer annexureIII-A
Providing of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units to refer annexureIII-A
100000000032Providingof cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units complete refer annexureIII-A
Providingof cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units complete refer annexureIII-A
100000000033Supply of rain proof outdoor duty as per IP-66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter refer annexureIII-A
Supply of rain proof outdoor duty as per IP-66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter refer annexureIII-A
100000000034Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY cable confirming EIC 4 core - 4 sqmm refer annexureIII-A
Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY cable confirming EIC 4 core - 4 sqmmrefer annexureIII-A
100000000035Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY as directed by EIC 4 core - 6 sqmm refer annexureIII-A
Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY as directed by EIC 4 core - 6 sqmm refer annexureIII-A
100000000036Supply of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFY as directed by EIC 4 core - 25 sqmm refer annexureIII-A
Supply of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XF as directed by EIC 4 core - 25 sqmm refer annexureIII-A
100000000037Supply of following size LT power cable with Copper conductor XLPEorPVC sheathed 1point1KV by EIC 4 core - 16 sqmm refer annexureIII-A
Supply of following size LT power cable with Copper conductor XLPEorPVC sheathed 1point1KV by EIC 4 core - 16 sqmm refer annexureIII-A
100000000038Supply of Copper cable of size 4 core - 2point5 sqmm for communication refer annexureIII-A
Supply of Copper cable of size 4 core - 2point5 sqmm for communication refer annexureIII-A
100000000039Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexureIII-A
Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexureIII-A
100000000040Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexureIII-A
Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexureIII-A
100000000041Installation testing and commissioning of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexure-III-B
Installation testing and commissioning of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexure-III-B
100000000042Installation testing and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-III-B
Installation testing and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-III-B
100000000043Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-III-B
Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-III-B
100000000044Installation testing and commissioning of suitable size refrigerant grade for 2or2.5or3or4TR Cassette ACorSplit AC unit for suction liquid refer annexure-III-B
Installation testing and commissioning of suitable size refrigerant grade for 2or2.5or3or4TR Cassette ACorSplit AC unit for suction liquid refer annexure-III-B
100000000045Laying of flexible PVC Duct hose Covering pipe of size 60 mm suitable for exposed refrigerant refer annexure-III-B
Laying of flexible PVC Duct hose Covering pipe of size 60 mm suitable for exposed refrigerant refer annexure-III-B
100000000046Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-III-B
Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-III-B
100000000047Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure-III-B
Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure-III-B
100000000048Installation testing and commissioning of rain proof outdoor duty as per IP-66 refer annexure-III-B
Installation testing and commissioning of rain proof outdoor duty as per IP-66 refer annexure-III-B
100000000049Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV gradeEIC 4 core - 6 sqmm refer annexure-III-B
Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV gradeEIC 4 core - 6 sqmm refer annexure-III-B
100000000050Laying of following size LT power cable with Copper conductor XLPEorPVC 1point1KV grade by EIC 4 core - 4 sqmm refer annexure-III-B
Laying of following size LT power cable with Copper conductor XLPEorPVC 1point1KV grade by EIC 4 core - 4 sqmm refer annexure-III-B
100000000051Laying of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFY cable as directed by EIC 4 core - 16 sqmm refer annexure-III-B
Laying of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFY cable as directed by EIC 4 core - 16 sqmm refer annexure-III-B
100000000052Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV grade as directed by EIC 4 core - 25 sqmm refer annexure-III-B
Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV grade as directed by EIC 4 core - 25 sqmm refer annexure-III-B
100000000053Laying of Copper cable of size 4 core - 2point5 sqmm for communication refer annexure-III-B
Laying of Copper cable of size 4 core - 2point5 sqmm for communication refer annexure-III-B
100000000054Laying of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-III-B
Laying of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-III-B
100000000055Laying of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-III-B
Laying of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-III-B
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | C73340001918Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure II-A | Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure II-A | 5 | nos | con5.bel.gzb | 45 | |
| 2 | C73340001724 Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure II-A | Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure II-A | 5 | nos | con5.bel.gzb | 45 | |
| 3 | C73340001821 Supply of Cassette AC four way capacity 4 TR rating Inverter type rotary scroll compressor aircooled condensing unit with copper cooling coil refer annexure II-A | Supply of Cassette AC four way capacity 4 TR rating Inverter type rotary scroll compressor aircooled condensing unit with copper cooling coil refer annexure II-A | 12 | nos | con5.bel.gzb | 45 | |
| 4 | 100000000001Supply of suitable size refrigerant grade copper piping for 2or2point5or3or 4TR Cassette ACorSplit AC unit Refer annexureII-A | Supply of suitable size refrigerant grade copper piping for 2or2point5or3or 4TR Cassette ACorSplit AC unit Refer annexureII-A | 550 | rmt | con5.bel.gzb | 45 | |
| 5 | 100000000002Providing flexible PVC Duct hose Covering pipeof size 60 mm suitable for exposed refrigerant pipes for cassttte AC units refer anexure II-A | Providing flexible PVC Duct hose Covering pipeof size 60 mm suitable for exposed refrigerant pipes for cassttte AC units refer anexure II-A | 200 | rmt | con5.bel.gzb | 45 | |
| 6 | 100000000003 ProvidingcPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for refer annexureII-A | ProvidingcPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for refer annexureII-A | 100 | rmt | con5.bel.gzb | 45 | |
| 7 | 100000000004 Providing cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexureII-A | Providing cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexureII-A | 120 | rmt | con5.bel.gzb | 45 | |
| 8 | 100000000005 Supply of rain proof outdoor duty as per IP-66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter digital ammeter indication lamps refer annexureII-A | Supply of rain proof outdoor duty as per IP-66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter digital ammeter indication lamps refer annexureII-A | 4 | nos | con5.bel.gzb | 45 | |
| 9 | 100000000006 Supply of following size LT power cable with Copper conductor XLPEorPVC as directed by EIC 4 core - 4 sqmm refer annexureII-A | Supply of following size LT power cable with Copper conductor XLPEorPVC as directed by EIC 4 core - 4 sqmm refer annexureII-A | 200 | rmt | con5.bel.gzb | 45 | |
| 10 | 100000000007 Supply of following size LT power cable with Copper conductor XLPEorPVC as directed by EIC 4 core - 6 sqmm refer annexureII-A | Supply of following size LT power cable with Copper conductor XLPEorPVC as directed by EIC 4 core - 6 sqmm refer annexureII-A | 200 | rmt | con5.bel.gzb | 45 | |
| 11 | 100000000008 Supply of following size LT power cable with Copper conductor laying of the same in by EIC 4core - 25 sqmm refer annexure-II-A | Supply of following size LT power cable with Copper conductor laying of the same in by EIC 4core - 25 sqmm refer annexure-II-A | 60 | rmt | con5.bel.gzb | 45 | |
| 12 | 100000000009Supply of following size LT power cable with Copper conductor as directed by EIC 4core - 16 sqmm refer annexure-II-A | Supply of following size LT power cable with Copper conductor as directed by EIC 4core - 16 sqmm refer annexure-II-A | 60 | rmt | con5.bel.gzb | 45 | |
| 13 | 100000000010 Supply of Copper cable of size 4core - 2point5 sqmm for communication refer annexure II-A | Supply of Copper cable of size 4core - 2point5 sqmm for communication refer annexure-II-A | 500 | rmt | con5.bel.gzb | 45 | |
| 14 | 100000000011 Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-A | Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-A | 120 | rmt | con5.bel.gzb | 45 | |
| 15 | 100000000012Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-A | Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-A | 75 | rmt | con5.bel.gzb | 45 | |
| 16 | 100000000013Installation testing and commissioning of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotaryorscroll compressor aircooled refer annexure-II-B | Installation testing and commissioning of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotaryorscroll compressor aircooled refer annexure-II-B | 5 | nos | con5.bel.gzb | 45 | |
| 17 | 100000000014Installationtesting and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type refer annexure-II-B | Installationtesting and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type refer annexure-II-B | 5 | nos | con5.bel.gzb | 45 | |
| 18 | 100000000015 Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor units refer annexure-II-B | Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor units refer annexure-II-B | 12 | nos | con5.bel.gzb | 45 | |
| 19 | 100000000016 Erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexure-II-B | Erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexure-II-B | 550 | rmt | con5.bel.gzb | 45 | |
| 20 | 100000000017Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable refer annexure-II-B | Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable refer annexure-II-B | 200 | rmt | con5.bel.gzb | 45 | |
| 21 | 100000000018 Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexure-II-B | Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexure-II-B | 100 | rmt | con5.bel.gzb | 45 | |
| 22 | 100000000019 Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-II-B | Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-II-B | 120 | rmt | con5.bel.gzb | 45 | |
| 23 | 100000000020 Erection testing and commissioning of rain proof outdoor duty as per IP-66 Electrical control panel annexure-II-B | Erection testing and commissioning of rain proof outdoor duty as per IP-66 Electrical control panel annexure-II-B | 4 | nos | con5.bel.gzb | 45 | |
| 24 | 100000000021 Laying of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed armoured extruded PVC oas directed by EIC 4 core - 4 sqmm refer annexure-II-B | Laying of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed armoured extruded PVC oas directed by EIC 4 core - 4 sqmm refer annexure-II-B | 200 | rmt | con5.bel.gzb | 45 | |
| 25 | 100000000022 Laying of following size LT power cable with Copper conductor XLPEorPVC insulation as directed by EIC 4 core - 6 sqmm refer annexure-II-B | Laying of following size LT power cable with Copper conductor XLPEorPVC insulation as directed by EIC 4 core - 6 sqmm refer annexure-II-B | 200 | rmt | con5.bel.gzb | 45 | |
| 26 | 100000000023Laying of following size LT power cable with Copper conductor as directed by EIC 4 core - 25 sqmm refer annexure-II-B | Laying of following size LT power cable with Copper conductor as directed by EIC 4 core - 25 sqmm refer annexure-II-B | 60 | rmt | con5.bel.gzb | 45 | |
| 27 | 100000000024Laying of following size LT power cable with Copper conductor XLPEorPVCas directed by EIC 4 core - 16 sqmm refer annexure-II-B | Laying of following size LT power cable with Copper conductor XLPEorPVCas directed by EIC 4 core - 16 sqmm refer annexure-II-B | 60 | rmt | con5.bel.gzb | 45 | |
| 28 | 100000000025Laying of Copper cable of size 4 core - 2point5 sqmm for communication refer annexure-II-B | Laying of Copper cable of size 4 core - 2point5 sqmm for communication refer annexure-II-B | 500 | rmt | con5.bel.gzb | 45 | |
| 29 | 100000000026Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-B | Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-B | 120 | rmt | con5.bel.gzb | 45 | |
| 30 | 100000000027Installing of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-B | Installing of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-B | 75 | rmt | con5.bel.gzb | 45 | |
| 31 | 100000000028Dismantling and shifting of existing Cassette AC 46 nos and VRV outdoor units of capacity 198 Hp refer annexure II-B | Dismantling and shifting of existing Cassette AC 46 nos and VRV outdoor units of capacity 198 Hp refer annexure-II-B | 1 | lot | con5.bel.gzb | 45 | |
| 32 | C73340100470Supply of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexureIII-A | Supply of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexureIII-A | 4 | nos | con5.bel.gzb | 45 | |
| 33 | C73340001724Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexureIII-A | Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexureIII-A | 3 | nos | con5.bel.gzb | 45 | |
| 34 | C73340001821Supply of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil fan motor refer annexureIII-A | Supply of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil fan motor refer annexureIII-A | 21 | nos | con5.bel.gzb | 45 | |
| 35 | 100000000029Supply of suitable size refrigerant grade copper piping between indoor and outdoor units for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexureIII-A | Supply of suitable size refrigerant grade copper piping between indoor and outdoor units for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexureIII-A | 400 | rmt | con5.bel.gzb | 45 | |
| 36 | 100000000030Providing of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling cassttte AC units refer annexureIII-A | Providing of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling cassttte AC units refer annexureIII-A | 100 | rmt | con5.bel.gzb | 45 | |
| 37 | 100000000031Providing of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units to refer annexureIII-A | Providing of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units to refer annexureIII-A | 80 | rmt | con5.bel.gzb | 45 | |
| 38 | 100000000032Providingof cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units complete refer annexureIII-A | Providingof cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units complete refer annexureIII-A | 80 | rmt | con5.bel.gzb | 45 | |
| 39 | 100000000033Supply of rain proof outdoor duty as per IP-66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter refer annexureIII-A | Supply of rain proof outdoor duty as per IP-66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter refer annexureIII-A | 4 | nos | con5.bel.gzb | 45 | |
| 40 | 100000000034Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY cable confirming EIC 4 core - 4 sqmm refer annexureIII-A | Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY cable confirming EIC 4 core - 4 sqmmrefer annexureIII-A | 175 | rmt | con5.bel.gzb | 45 | |
| 41 | 100000000035Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY as directed by EIC 4 core - 6 sqmm refer annexureIII-A | Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY as directed by EIC 4 core - 6 sqmm refer annexureIII-A | 175 | rmt | con5.bel.gzb | 45 | |
| 42 | 100000000036Supply of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFY as directed by EIC 4 core - 25 sqmm refer annexureIII-A | Supply of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XF as directed by EIC 4 core - 25 sqmm refer annexureIII-A | 60 | rmt | con5.bel.gzb | 45 | |
| 43 | 100000000037Supply of following size LT power cable with Copper conductor XLPEorPVC sheathed 1point1KV by EIC 4 core - 16 sqmm refer annexureIII-A | Supply of following size LT power cable with Copper conductor XLPEorPVC sheathed 1point1KV by EIC 4 core - 16 sqmm refer annexureIII-A | 60 | rmt | con5.bel.gzb | 45 | |
| 44 | 100000000038Supply of Copper cable of size 4 core - 2point5 sqmm for communication refer annexureIII-A | Supply of Copper cable of size 4 core - 2point5 sqmm for communication refer annexureIII-A | 450 | rmt | con5.bel.gzb | 45 | |
| 45 | 100000000039Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexureIII-A | Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexureIII-A | 80 | rmt | con5.bel.gzb | 45 | |
| 46 | 100000000040Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexureIII-A | Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexureIII-A | 25 | rmt | con5.bel.gzb | 45 | |
| 47 | 100000000041Installation testing and commissioning of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexure-III-B | Installation testing and commissioning of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexure-III-B | 4 | nos | con5.bel.gzb | 45 | |
| 48 | 100000000042Installation testing and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-III-B | Installation testing and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-III-B | 3 | nos | con5.bel.gzb | 45 | |
| 49 | 100000000043Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-III-B | Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-III-B | 21 | nos | con5.bel.gzb | 45 | |
| 50 | 100000000044Installation testing and commissioning of suitable size refrigerant grade for 2or2.5or3or4TR Cassette ACorSplit AC unit for suction liquid refer annexure-III-B | Installation testing and commissioning of suitable size refrigerant grade for 2or2.5or3or4TR Cassette ACorSplit AC unit for suction liquid refer annexure-III-B | 400 | rmt | con5.bel.gzb | 45 | |
| 51 | 100000000045Laying of flexible PVC Duct hose Covering pipe of size 60 mm suitable for exposed refrigerant refer annexure-III-B | Laying of flexible PVC Duct hose Covering pipe of size 60 mm suitable for exposed refrigerant refer annexure-III-B | 100 | rmt | con5.bel.gzb | 45 | |
| 52 | 100000000046Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-III-B | Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-III-B | 80 | rmt | con5.bel.gzb | 45 | |
| 53 | 100000000047Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure-III-B | Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure-III-B | 80 | rmt | con5.bel.gzb | 45 | |
| 54 | 100000000048Installation testing and commissioning of rain proof outdoor duty as per IP-66 refer annexure-III-B | Installation testing and commissioning of rain proof outdoor duty as per IP-66 refer annexure-III-B | 4 | nos | con5.bel.gzb | 45 | |
| 55 | 100000000049Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV gradeEIC 4 core - 6 sqmm refer annexure-III-B | Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV gradeEIC 4 core - 6 sqmm refer annexure-III-B | 175 | rmt | con5.bel.gzb | 45 | |
| 56 | 100000000050Laying of following size LT power cable with Copper conductor XLPEorPVC 1point1KV grade by EIC 4 core - 4 sqmm refer annexure-III-B | Laying of following size LT power cable with Copper conductor XLPEorPVC 1point1KV grade by EIC 4 core - 4 sqmm refer annexure-III-B | 175 | rmt | con5.bel.gzb | 45 | |
| 57 | 100000000051Laying of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFY cable as directed by EIC 4 core - 16 sqmm refer annexure-III-B | Laying of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFY cable as directed by EIC 4 core - 16 sqmm refer annexure-III-B | 60 | rmt | con5.bel.gzb | 45 | |
| 58 | 100000000052Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV grade as directed by EIC 4 core - 25 sqmm refer annexure-III-B | Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV grade as directed by EIC 4 core - 25 sqmm refer annexure-III-B | 60 | rmt | con5.bel.gzb | 45 | |
| 59 | 100000000053Laying of Copper cable of size 4 core - 2point5 sqmm for communication refer annexure-III-B | Laying of Copper cable of size 4 core - 2point5 sqmm for communication refer annexure-III-B | 450 | rmt | con5.bel.gzb | 45 | |
| 60 | 100000000054Laying of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-III-B | Laying of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-III-B | 80 | rmt | con5.bel.gzb | 45 | |
| 61 | 100000000055Laying of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-III-B | Laying of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-III-B | 25 | rmt | con5.bel.gzb | 45 |
Start
21-Mar-2025, 3:00 pm
End
22-Mar-2025, 6:15 pm
Duration: 28 hours
Reverse Auction Document
✅ RA concluded. Check financial results for final rankings.
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | AIR CARE ELECTRONICS Under PMA | - | 10-03-2025 19:54:36 | |
| 2 | GAYATRI AIRCON PRIVATE LIMITED Under PMA | - | 10-03-2025 18:21:59 | |
| 3 | ISHA ENTERPRISES Under PMA | - | 10-03-2025 17:45:29 | |
| 4 | TEZZ WEB & BUSINESS SOLUTION PRIVATE LIMITED Under PMA | - | 10-03-2025 14:38:16 | |
| 5 | TRANSCEND CONTRACTS PRIVATE LIMITED Under PMA | - | 06-03-2025 19:29:25 |
These are the final prices after the reverse auction event. Prices may be lower than initial bids.
| Rank | Seller | Final Price | Item |
|---|---|---|---|
| L1 | GAYATRI AIRCON PRIVATE LIMITED(MSE,MII) Under PMA Winner | ₹81,94,093 | Item Categories : C73340001918Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type |
| L2 | AIR CARE ELECTRONICS (MII) Under PMA | ₹82,03,150 | Item Categories : C73340001918Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type |
| L3 | ISHA ENTERPRISES (MII) Under PMA | ₹1,12,07,483 | Item Categories : C73340001918Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type |
🎉 L1 Winner
GAYATRI AIRCON PRIVATE LIMITED(MSE,MII) Under PMA
Final Price: ₹81,94,093
Key insights about UTTAR PRADESH tender market
The eligibility requirements for participating bidders include being a registered entity capable of fulfilling the technical specifications outlined in the tender. Bidders must also demonstrate prior experience with similar projects, ensuring they have a proven track record to manage successful outcomes within the procurement framework.
Bidders must submit certificates that confirm adherence to all relevant quality standards and compliance requirements established for the project. This includes documentation for the manufacturing processes, quality assurance protocols, and detailed specifications for the Cassette AC units to ensure alignment with tender requirements.
The submission process mandates that all documents are uploaded through the designated online portal. Accepted document formats typically include PDF for technical specifications and Excel for financial bids, thus ensuring standardization across submissions. Proper formatting significantly aids evaluators in reviewing the proposals effectively.
Participants in the tender are required to submit an Earnest Money Deposit (EMD) as a commitment to their bid. Upon the successful award of a contract, a performance security will be mandated to safeguard against non-fulfillment of contractual obligations, reinforcing the importance of serious bidding in the procurement process.
The tender includes special provisions aimed at promoting the participation of Micro, Small and Medium Enterprises (MSMEs), along with startups. These incentives encompass relaxed eligibility criteria and possibly preferential evaluation considerations, allowing smaller organizations to effectively compete within the tender marketplace while fostering innovation in public procurement.
State Bank Of India (sbi)
📍 VARANASI, UTTAR PRADESH
Bharat Heavy Electricals Limited (bhel)
📍 HARIDWAR, UTTARAKHAND
Department of Power
📍 PATIALA, PUNJAB
State Bank Of India (sbi)
📍 GORAKHPUR, UTTAR PRADESH
Indian Space Research Organization
📍 HASSAN, KARNATAKA
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS