High End Multipara Monitor (V3)
N/a
PATAN, GUJARAT
Progress
Quantity
8
Bid Type
Two Packet Bid
All India Institute Of Medical Sciences (aiims) invites bids for High End Multipara Monitor (V3) (Q2) in PATNA, BIHAR. Quantity: 8. Submission Deadline: 08-07-2026 18: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
High End Multipara Monitor (V3) (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
PATAN, GUJARAT
Central University Of Gujarat
VADODARA, GUJARAT
Directorate Of Medical Education And Training
CHANDAULI, UTTAR PRADESH
N/a
LUCKNOW, UTTAR PRADESH
Ssg Hospital Vadodara
VADODARA, GUJARAT
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Product Specifications | Type of Monitor | Modular |
| Product Specifications | Monitoring Parameters | ECG, HR, Respiration Rate, SpO2, Pulse Rate, NIBP, Temperature, IBP |
| Product Specifications | EtCO2 | Yes |
| Product Specifications | Cardiac output | Invasive (Thermodilution) |
| Product Specifications | Transport monitor module with basic vital parameters for transporting within the hospital | No |
| Product Specifications | AEEG (Amplitude Integrated Electroencephalography)Trend Graph | No |
| Product Specifications | Depth of Anesthesia Monitoring | No |
| Product Specifications | Perfusion Index | Yes |
| Product Specifications | Transcutaneous PO2 / PCO2 | No |
| Product Specifications | S T Analysis | Yes |
| Product Specifications | PPV (derived value during IBP measurement) | Yes |
| Product Specifications | Regional Oximetry | No |
| Product Specifications | Length of time of full disclosure of patient data in hr | ≥ 72 Or higher |
| Product Specifications | Length of time of trending in hr | ≥ 72 Or higher |
| Generic | Product Description | High End Multipara Monitor |
| ECG PARAMETERS | ECG Provided | Yes |
| ECG PARAMETERS | Number of leads of ECG | 5 |
| ECG PARAMETERS | 12-Lead interpretation for ECG | Yes |
| ECG PARAMETERS | ECG Waveform number of leads display | 7 |
| ECG PARAMETERS | Arrhythmia detect | Yes |
| ECG PARAMETERS | Heart rate measurement range | Atleast 30 -250 bpm |
| ECG PARAMETERS | Accuracy | ± 2 bpm or better |
| ECG PARAMETERS | Minimum gradation | 1 bpm or better |
| RESPIRATION PARAMETERS | Respiration Method | Impedance pneumography |
| RESPIRATION PARAMETERS | Display waveform of respiration | Yes |
| RESPIRATION PARAMETERS | Respiration rate measurement range | 0 - 100 bpm or more |
| RESPIRATION PARAMETERS | Minimum gradation of respiratory measurement | 1 bpm or better |
| PULSE OXIMETERY PARAMETERS | Measurement technique (Declaration of the measurement technique by the seller at the time of bid submission/supply) | Low Perfusion Technology with Motion artifact detection |
| PULSE OXIMETERY PARAMETERS | Probe type | Clip |
| PULSE OXIMETERY PARAMETERS | Probe for Adult and Pediatric | Reusable |
| PULSE OXIMETERY PARAMETERS | Probe for neonates | Reusable |
| PULSE OXIMETERY PARAMETERS | SPO2 measurement range | 40 - 100% |
| PULSE OXIMETERY PARAMETERS | Accuracy of SPO2 measurement | ± 2% or better |
| PULSE OXIMETERY PARAMETERS | Minimum Gradation | 1% |
| NIBP PARAMETERS | Measurement technique for NIBP | Step-deflation Oscillometric / Linear Inflation |
| NIBP PARAMETERS | Systolic Blood pressure monitoring range | 30 - 300 mmHg or more |
| NIBP PARAMETERS | Diastolic Blood pressure monitoring range | 10 - 200 mmHg or more |
| NIBP PARAMETERS | Accuracy of NIBP Measurement | ±1 mm/Hg or better |
| TEMPERATURE PARAMETERS | Number of channels for temperature | 2 |
| TEMPERATURE PARAMETERS | Type of probe | Skin |
| TEMPERATURE PARAMETERS | Temperature probe type | Reusable |
| TEMPERATURE PARAMETERS | Temperature probe range | Atleast 30 - 40 degree |
| TEMPERATURE PARAMETERS | Minimum gradation of temperature probe | 0.1 degree C or better |
| TEMPERATURE PARAMETERS | Accuracy in % | ±1% or better |
| IBP PARAMETERS | Number of channels for IBP | 2 |
| ETCO2 PARAMETERS | Sensor type | Sidestream |
| ETCO2 PARAMETERS | Patient type | Intubated and non intubated |
| ETCO2 PARAMETERS | CO2 Measuring range ( in mmHg ) | 0 to 99 mmHg or better |
| ALARMS | Availability of Audio and visual alarms with high , medium and low intensity adjustment | Yes |
| ALARMS | Operator can set audio visual alarm levels for low or high levels of each parameter independently | Yes |
| ALARMS | Systolic BP - low and high | Yes |
| ALARMS | Diastolic BP - low and high | Yes |
| ALARMS | Mean BP - low and high | Yes |
| ALARMS | Heart rate - low and high | Yes |
| ALARMS | SPO2 - low and high | Yes |
| ALARMS | Respiratory rate - low and high | Yes |
| ALARMS | Temperature - low and high | Yes |
| ALARMS | Alarm Volume Adjustable | Yes |
| ALARMS | Activating silence of alarm | Yes |
| ALARMS | Duration of alarm silence ( in seconds ) | 120 |
| ALARMS | Suspension of all alarms | Yes |
| ALARMS | Latching of alarm | No |
| ALARMS | Cuff leakage alarm | Yes |
| ALARMS | Cuff disconnect alarm | Yes |
| ALARMS | Alarm for inflation/deflation errors | Yes |
| ALARMS | Indicator for low-battery | Yes |
| ALARMS | EtCO2 - low and high | Yes |
| ALARMS | Escalation of Alarm Priority | Yes |
| ALARMS | Sensor/ wire/probe disconnection alarm | Yes |
| NETWORK PARAMETERS | Ethernet port | Yes |
| NETWORK PARAMETERS | Hardwired | Yes |
| NETWORK PARAMETERS | Wireless | No |
| NETWORK PARAMETERS | Connectivity with Network printer | Yes |
| NETWORK PARAMETERS | Connectivity provision with Central Nursing Station | Yes |
| DISPLAY PARAMETERS | Type of display | LCD/LED/TFT |
| DISPLAY PARAMETERS | Display Size in inches | 17, 19 Or higher |
| DISPLAY PARAMETERS | Traces of display | >6 |
| DISPLAY PARAMETERS | User Interface of display | Touchscreen and Rotary knob Or higher |
| DISPLAY PARAMETERS | Inbuilt thermal Recorder (Printer) | No |
| DISPLAY PARAMETERS | Should be able to connect to additional display | Yes |
| STANDARD ACCESSORIES | Number of reusable adult probe provided | 1 |
| STANDARD ACCESSORIES | Number of reusable pediatric probe provided | NA |
| STANDARD ACCESSORIES | Number of reusable neonatal probe provided | NA |
| STANDARD ACCESSORIES | Number of Disposable neonate probes provided | NA |
| STANDARD ACCESSORIES | Number of ECG 5/6/10 lead cable provided | 1 |
| STANDARD ACCESSORIES | Number of Neonatal ECG 3/5/6 lead cable provided | Not Provided |
| STANDARD ACCESSORIES | Number of IBP cables provided | 2 Reusable Cables |
| STANDARD ACCESSORIES | Number of Skin temperature probe provided | 1 for Adult / Paediatric |
| STANDARD ACCESSORIES | Number of Neonatal Rectal temperature Probe provided | NA |
| STANDARD ACCESSORIES | Accessories to wall mount the monitor | Yes |
| POWER REQUIREMENTS | Power supply | Single Phase 220-240 VAC, 50Hz |
| POWER REQUIREMENTS | Mains cable | 3 meter or more with Indian plug |
| POWER REQUIREMENTS | Battery | Inbuilt |
| POWER REQUIREMENTS | Minimum Inbuilt Battery back up ( in minutes ) | 120 |
| POWER REQUIREMENTS | Recharging time of battery ( in hr ) | ≤ 6 |
| POWER REQUIREMENTS | Weight of the Machine in kgs | ≤ 15 |
| POWER REQUIREMENTS | Noise level ( in dB ) | ≤ 50 |
| POWER REQUIREMENTS | Device Earthing | Yes |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | Conformity to Electrical Safety Standards | IEC 60601 or BIS Equivalent |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Gujarat Medical Education And Research Society (gmers)
📍 VALSAD, GUJARAT
Sanjay Gandhi Post Graduate Institute Of Medical Sciences Lucknow
📍 LUCKNOW, UTTAR PRADESH
Directorate Of Medical Education
📍 DIBRUGARH, ASSAM
Central Railway
📍 SOLAPUR, MAHARASHTRA
Tata Memorial Centre Mpmmcc And Hbch Varanasi Madh
📍 VARANASI, UTTAR PRADESH
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS