N/a invites bids for Ultrasound Machine (V2) (Q2) in SURGUJA, CHHATTISGARH. Quantity: 2. Submission Deadline: 14-09-2026 13: 00: 00. Submit your proposal before the deadline.
Quantity
2
Bid Type
Two Packet Bid
Bid Validity
90 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
No
MSE Purchase Preference
No
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Min. Avg. Annual Turnover
20
OEM Avg. Turnover
120
Past Performance
80 %
Warranty Period
15 years
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Ultrasound Machine (V2) (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
3%
ePBG Duration (Months)
65
Payment Timelines
Payments shall be made to the Seller within 30 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Balrampur
Delivery Pincodes
497001
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Prem Singh Marko | 497001,Office of the Chief Medical and Health Officer, Darri Para, Ambikapur District- Surguja (Chhattisgarh) | Balrampur | Chhattisgarh | 497001 | 2 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| Types of Probes & Features | Applications | Abdomen, Abdominal vascular, Urology, OB/GYN, Neonatal brain, Small parts (breast, thyroid, scrotal, prostate, musculoskeletal) |
| Types of Probes & Features | Convex Probe | 2.5 to 5 MHz (±2) |
| Types of Probes & Features | Microconvex probe | 4 to 8 MHz (±2), Not Provided |
| Types of Probes & Features | Linear array probe | 5 to 10 MHz (±2), 3 to 12 MHz (±2) |
| Types of Probes & Features | TVS Probe | 4 to 9 MHz (±2), Not Provided |
| Types of Probes & Features | Cardiac Probe | 1 to 5 MHz (±2), Not Provided |
| Types of Probes & Features | Hockey Stick Probe | Not Provided |
| Types of Probes & Features | Volume Convex Probe | 2.5 to 5 MHz (±2), Not Provided |
| Types of Probes & Features | Volume Linear Probe | Not Provided |
| Types of Probes & Features | Volume TVS Probe | Not Provided |
| Types of Probes & Features | Endorectal Probe | Not Provided |
| Types of Probes & Features | E-Breast Elastography technique | No, Yes |
| Types of Probes & Features | E-Thyroid Elastography technique | No, Yes |
| Types of Probes & Features | Liver Elastography technique | No, Yes |
| Types of Probes & Features | Gel Warmer | No, Yes |
| Types of Probes & Features | Dedicated 3-D/4-D | No, Yes |
| Scan Modes | B-mode | Yes |
| Scan Modes | M-mode | Yes |
| Scan Modes | Contrast harmonic imaging with angio mode | Yes, No |
| Scan Modes | Tissue harmonic imaging mode | Yes |
| Scan Modes | Provision of Harmonic imaging in Linear Probes | Yes |
| Scan Modes | Color Doppler imaging (CDI) | Yes |
| Scan Modes | Color Doppler 3-D/4-D option | No, Yes |
| Scan Modes | Power Doppler imaging (PDI) | Yes |
| Scan Modes | Power Doppler 3-D/4-D option | No, Yes |
| Scan Modes | Continuous wave | No |
| Scan Modes | Pulsed wave | Yes |
| Scan Modes | Duplex mode | Yes |
| Scan Modes | Triplex mode | Yes, No |
| Scan Modes | Tissue Doppler imaging | Yes, No |
| Scan Modes | Contrast-enhanced ultrasound (CEUS) option | No, Yes |
| Scan Modes | Tissue synchronization, tissue velocity | Yes, No |
| Scan Modes | Gain control in two dimensions for additional level of flexibility for image quality control | Yes |
| Scan Modes | Provision for higher resolution | Real time high frequency 2D |
| Scan Modes | Probes supplied shall be in latest generation bandwidth | Yes |
| Scan Modes | Provision for higher sensitivity for low frequency doppler in all probes | Yes, No |
| Scan Modes | Number of channels in color doppler system | 50000 or more (if channels are being designated as digital channels) |
| Scan Modes | Live 3 D imaging in color doppler system | Yes, No |
| Scan Modes | Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval | Yes, No |
| Scan Modes | Number of grey shades for sharp contrast resolutions in db | 256 or more |
| Scan Modes | High-definition acoustic zoom provision for enlarging sections of 2D and Colour flow images with more acoustic information for greater clarity and detail while maintaining an optimal frame rate | Yes |
| Scan Modes | Colour Flow Imaging Option | Yes |
| Scan Modes | Provision of Tissue Colorization (B-Colour) for improved contrast resolution | Yes |
| Scan Modes | All application packages should be inbuilt into the system | Yes |
| Scan Modes | Cine Loop Features | Yes, No |
| Scan Modes | Cine Loop Memory in MB | >=100 |
| Scan Modes | Frame grabber facility for post analysis | Yes, No |
| Scan Modes | User defined system and application presets for multi-user department | Yes |
| Scan Modes | Number of transducer/probe ports | 4 or More |
| Scan Modes | System should be capable of generating real time live 3- D images | Yes, No |
| Scan Modes | Contrast agent imaging | Yes, No |
| Image Display and Processing | DICOM 3 Compliant | Yes |
| Image Display and Processing | Automated B-mode (2-D) image | Yes, No |
| Image Display and Processing | Automated CDI(Color Doppler Imaging) image optimization | Yes, No |
| Image Display and Processing | Automated PW Doppler image optimization | Yes, No |
| Image Display and Processing | Real-time image | Yes |
| Image Display and Processing | Touch Screen | No, Yes |
| Image Display and Processing | Monitor shall have high-resolution | Yes |
| Image Display and Processing | Type of Display | LCD/LED |
| Image Display and Processing | Monitor display size (inch) | 21 or more Or higher |
| Image Display and Processing | Split screen | Twin View, Twin View and Live Quad Screen, No |
| Image Display and Processing | Single/dual monitors | Single, Single with optional second console, Dual (image display and touch panel) |
| Image Display and Processing | Depth, cm | ≥30 |
| Image Display and Processing | Digital Image Storage | Yes |
| Image Display and Processing | Max number frames | >=1000 |
| Image Display and Processing | Digital storage hard drive, GB | >=500 |
| Image Display and Processing | Speckle-tracking strain and strain rate | No |
| Image Display and Processing | DVD/CD Writer/ USB | Yes |
| Image Display and Processing | Flash Memory | No |
| Image Display and Processing | USB connector | Yes |
| Image Display and Processing | Type of processor (in PC) | i7 or latest, NA |
| Image Display and Processing | RAM capacity of PC in GB (hint: In case PC not provided put zero) | ≥ 4, NA |
| Image Display and Processing | Processor speed in GHz (PC) | ≥ 3, NA |
| Image Display and Processing | Frame Grabber incorporated(PC) | Yes, No |
| Image Display and Processing | Connectivity between USG and PC | No, Yes |
| Image Display and Processing | PC with all software inclusive interfaced with USG machine | Yes, No |
| Image Display and Processing | Laser Color printer provided | Yes |
| Image Display and Processing | Inkjet/Thermal printer provided | Yes, No |
| Image Display and Processing | CD/DVD/USB Produced should be playable on any system | Yes |
| Image Display and Processing | Glossy Colour Print Paper supplied | 500 sheets, 1000 sheets, NA |
| Image Display and Processing | Dicom Interfacability Dicom to PACS | Yes, No |
| Image Display and Processing | Interfacability Dicom to RIS | Yes, No |
| Image Display and Processing | USG sytem supplied should be upgradable to next generation system on site | Yes |
| Power Requirements | Power input, VAC | 220-240VAC, 50Hz fitted with Indian plug |
| Power Requirements | Resettable over current breaker shall be fitted for protection | Yes, No |
| Power Requirements | Power backup | UPS |
| Power Requirements | Back up time in minutes (minimum) | 30.0 |
| Power Requirements | Suitable Servo Controlled Stabilizer / CVT should be provided | Yes, No |
| Certifications | Availability of valid drug/Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| Certifications | Certification for manufacturing unit | ISO:13485 (Latest) |
| Warranty and Maintenance | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3, 5 Or higher |
| Miscellaneous Requirements | Training of users in operation and basic maintenance shall be provided | Yes |
| Miscellaneous Requirements | Certificate of calibration from the manufacturer | Yes |