TenderDekho Logo
GEM

Open Tender for ACMC 1ST YEAR,ACMC 2ND YEAR,Operation 1st year,Operation 2nd year,Supply of 4X6 Sqmm copper cable,S in GHAZIABAD, UTTAR PRADESH

Bid Publish Date

19-Apr-2025, 3:14 pm

Bid End Date

12-May-2025, 4:00 pm

EMD

₹84,900

Value

₹84,87,405

Progress

Issue19-Apr-2025, 3:14 pm
AwardPending
Explore all 5 tabs to view complete tender details

Quantity

860

Bid Type

Two Packet Bid

Categories 42

Airports Authority Of India, rhq Nr - Rangpuri has released a public tender for ACMC 1ST YEAR, ACMC 2ND YEAR, Operation 1st year, Operation 2nd year, Supply of 4X6 Sqmm copper cable, Supply of 4X10 Sqmm copper cable, Supply of 4X16 Sqmm copper cable, End Termination of 4X6 Sqmm copper cable, End Termination of 4X10 Sqmm copper cable, End Termination of 4X16 Sqmm copper cable, Laying of cable in RCC, Hume, Pipe upto 35 Sqmm, Laying and Fixing cable upto 35 sqmm, Wiring for Circuit submain 2X1 5 Sqmm plus 1X1 5 Sqmm, Wiring for Circuit submain 2X2 5 Sqmm plus 1X2 5 Sqmm, Wiring for Circuit submain 2X4 Sqmm plus 1X4 Sqmm, Wiring for Circuit submain 4X2 5 Sqmm plus 2X2 5 Sqmm, Wiring for Circuit submain 4X4 Sqmm plus 2X4 Sqmm in GHAZIABAD, UTTAR PRADESH. Quantity: 860. Submission Deadline: 12-05-2025 16: 00: 00. Download documents and apply online.

Documents 5

GeM-Bidding-7753063.pdf

Main Document

BOQ Document

BOQ

BOQ Document

BOQ

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Ex-work supply for 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE,Ex work supply for 1.1KV GRADE 10CX2.5 SQM

Power Grid Corporation Of India Limited

KACHCHH, GUJARAT

Posted: 2 September 2025
Closed: 11 October 2025
GEM

PVC COPPER CABLE 4 X 4 SQM,4 CORE X 16 SQMM PVC COPPER CABLE 660 1100V,PVC INSULATED FLEX CABLE 3C

Visvesvaraya Iron And Steel Plant

SHIMOGA, KARNATAKA

Posted: 16 August 2025
Closed: 26 August 2025
GEM

Ex work supply for 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE,Ex work supply for 1.1KV GRADE 10CX2.5 SQM

Power Grid Corporation Of India Limited

ALWAR, RAJASTHAN

Posted: 2 September 2025
Closed: 10 October 2025
GEM

Supply of 3 and half Core x 50 Sqmm Al Cable,Supply of 4 core x 16 Sqmm Al Cable,Supply of 4 core x

Bharat Dynamics Limited

HYDERABAD, TELANGANA

Posted: 5 August 2025
Closed: 16 August 2025
GEM

Hindustan Petroleum Corporation Ltd Cable Supply Tender 2025 India – 4C/1C Copper Cable & Cat6 Armoured Specifications

Hindustan Petroleum Corporation Ltd

GORAKHPUR, UTTAR PRADESH

Posted: 7 November 2025
Closed: 17 November 2025
GEM

Bill of Quantities (BOQ) 17 Items

Item # Title Description Quantity Unit Consignee Delivery (Days)
1 ACMC 1ST YEAR Annual Comprehensive Maintenance of 250 HP LG Make VRF System comprising of following outdoor and indoor units installed at Hindon Airport including providing and replacement of defective compressor by original company make new compressor and other defective component with original spares including central remote controller electrical panel board for VRF System carrying out routine preventive and breakdown maintenance etc as per recommendation of OEM and as per the terms and conditions of the contract a ODU - 26 HP Heating and Cooling - 01 nos Model no ARUN260LTES b ODU - 22 HP Heating and Cooling - 02 nos Model no JRUN220LLN4 c ODU - 20 HP Heating and Cooling - 01 nos Model No JRUN200LTES d ODU - 18 HP Heating and Cooling - 03 nos Model No JRUN180LLS4 e ODU - 16HP Heating and Cooling - 04 nos Model No JRUN160LLS4_JRUN160LTES f ODU - 14HP Heating and Cooling - 03 nos Model No JRUN140LLS4_JRUN140LTES g IDU -Ceiling Mounted AHUs 5000 CFM each - 05 nos Make- Edgetech h IDU - Ceiling Mounted AHUs 5400 CFM each - 04 nos Make- Edgetech i IDU - Ceiling Mounted Cassette Unit Four Way 0 8 TR - 02 nos Make-LG j IDU - Ceiling Mounted Cassette Unit Four Way 1 TR - 04 nos Make-LG k IDU - Ceiling Mounted Split Unit 0 63 TR - 01 nos Make-LG l IDU - Ceiling Mounted Split Unit 0 8 TR - 04 nos Make-LG m IDU - Ceiling Mounted Split Unit 1 TR - 03nos Make-LG n IDU - Ceiling Mounted Split Unit 1 6 TR - 03nos Make-LG o IDU - Floor Mounted Split Unit 8 TR -7 nos Make LG p IDU - Floor Mounted Split Unit 4 TR -8 nos Make LG 12 month engg_hindon 730
2 ACMC 2ND YEAR Annual Comprehensive Maintenance of 250 HP LG Make VRF System comprising of following outdoor and indoor units installed at Hindon Airport including providing and replacement of defective compressor by original company make new compressor and other defective component with original spares including central remote controller electrical panel board for VRF System carrying out routine preventive and breakdown maintenance etc as per recommendation of OEM and as per the terms and conditions of the contract a ODU - 26 HP Heating and Cooling - 01 nos Model no ARUN260LTES b ODU - 22 HP Heating and Cooling - 02 nos Model no JRUN220LLN4 c ODU - 20 HP Heating and Cooling - 01 nos Model No JRUN200LTES d ODU - 18 HP Heating and Cooling - 03 nos Model No JRUN180LLS4 e ODU - 16HP Heating and Cooling - 04 nos Model No JRUN160LLS4_JRUN160LTES f ODU - 14HP Heating and Cooling - 03 nos Model No JRUN140LLS4_JRUN140LTES g IDU -Ceiling Mounted AHUs 5000 CFM each - 05 nos Make- Edgetech h IDU - Ceiling Mounted AHUs 5400 CFM each - 04 nos Make- Edgetech i IDU - Ceiling Mounted Cassette Unit Four Way 0 8 TR - 02 nos Make-LG j IDU - Ceiling Mounted Cassette Unit Four Way 1 TR - 04 nos Make-LG k IDU - Ceiling Mounted Split Unit 0 63 TR - 01 nos Make-LG l IDU - Ceiling Mounted Split Unit 0 8 TR - 04 nos Make-LG m IDU - Ceiling Mounted Split Unit 1 TR - 03nos Make-LG n IDU - Ceiling Mounted Split Unit 1 6 TR - 03nos Make-LG o IDU - Floor Mounted Split Unit 8 TR -7 nos Make LG p IDU - Floor Mounted Split Unit 4 TR -8 nos Make LG 12 month engg_hindon 730
3 Operation 1st year Operation of 250 TR LG make VRF Airconditioning system in two shifts each of 8 hours duration on all days including Saturday Sundays holidays and National holidays etc and carrying out the routine cleaning and checking activities and maintaining records documentation etc complete as per terms and conditions of contract and as directed by Engineer-Incharge by deploying the following minimum manpower (a) Supervisor (Highly Skilled) - 01 No (Excluding Reliever) (b) Technician (Skilled)-03 Nos. (Excluding Reliever) (c) Helper (Unskilled) - 02 Nos (Excluding Reliever) Note If additional equipments installations provided or capacity of the existing AC system augmented during the currency of this contract the additional equipments installations plant shall be operated and records maintained by the contractor with the existing manpower within the quoted cost and nothing extra shall be paid on account of this 12 month engg_hindon 730
4 Operation 2nd year Operation of 250 TR LG make VRF Airconditioning system in two shifts each of 8 hours duration on all days including Saturday Sundays holidays and National holidays etc and carrying out the routine cleaning and checking activities and maintaining records documentation etc complete as per terms and conditions of contract and as directed by Engineer-Incharge by deploying the following minimum manpower (a) Supervisor (Highly Skilled) - 01 No (Excluding Reliever) (b) Technician (Skilled)-03 Nos. (Excluding Reliever) (c) Helper (Unskilled) - 02 Nos (Excluding Reliever) Note If additional equipments installations provided or capacity of the existing AC system augmented during the currency of this contract the additional equipments installations plant shall be operated and records maintained by the contractor with the existing manpower within the quoted cost and nothing extra shall be paid on account of this 12 month engg_hindon 730
5 Supply of 4X6 Sqmm copper cable Supply of PVC XLPE insulated copper conductor armoured cable confirming to the relevant IS specifications with upto date ammendments 4C X 6 sqmm 50 metre engg_hindon 730
6 Supply of 4X10 Sqmm copper cable Supply of PVC XLPE insulated copper conductor armoured cable confirming to the relevant IS specifications with upto date ammendments 4C X 10 sqmm 50 metre engg_hindon 730
7 Supply of 4X16 Sqmm copper cable Supply of PVC XLPE insulated copper conductor armoured cable confirming to the relevant IS specifications with upto date ammendments 4C X 16 sqmm 50 metre engg_hindon 730
8 End Termination of 4X6 Sqmm copper cable Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed XLPE copper conductor cable of 1-1kV grade as required(Note The item shall be executed as per requirement) 4C X 6 sq mm 4 set engg_hindon 730
9 End Termination of 4X10 Sqmm copper cable Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed XLPE copper conductor cable of 1-1kV grade as required(Note The item shall be executed as per requirement) 4C X 10 sq mm 4 set engg_hindon 730
10 End Termination of 4X16 Sqmm copper cable Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed XLPE copper conductor cable of 1-1kV grade as required(Note The item shall be executed as per requirement) 4C X16 sq mm 4 set engg_hindon 730
11 Laying of cable in RCC, Hume, Pipe upto 35 Sqmm Laying of one number PVC insulated and PVC sheathed XLPE power control Aluminium copper conductor cable of 1-1 KV grade of following size in the existing RCC HUME METAL HDPE pipe as required (Note The item shall be executed as and when required) Upto 35 sq mm 50 metre engg_hindon 730
12 Laying and Fixing cable upto 35 sqmm Laying and fixing of one number PVC insulated and PVC sheathed XLPE power cable of 1-1 KV grade of following size on wall surface as required (Note The item shall be executed as and when required) Upto 35 sq mm (clamped with 1mm thick saddle) 100 metre engg_hindon 730
13 Wiring for Circuit submain 2X1 5 Sqmm plus 1X1 5 Sqmm Wiring for circuit submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit as required (Note The item shall be executed as and when required) 2 X 1.5 sq mm + 1 X 1.5 sq mm earth wire 100 metre engg_hindon 730
14 Wiring for Circuit submain 2X2 5 Sqmm plus 1X2 5 Sqmm Wiring for circuit submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit as required (Note The item shall be executed as and when required) 2 X 2.5 sq mm + 1 X 2.5 sq mm earth wire 100 metre engg_hindon 730
15 Wiring for Circuit submain 2X4 Sqmm plus 1X4 Sqmm Wiring for circuit submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit as required (Note The item shall be executed as and when required) 2 X 4 sq mm + 1 X 4 sq mm earth wire 100 metre engg_hindon 730
16 Wiring for Circuit submain 4X2 5 Sqmm plus 2X2 5 Sqmm Wiring for circuit submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit as required (Note The item shall be executed as and when required) 4 X 2.5 sq mm + 2 X 2.5 sq mm earth wire 100 metre engg_hindon 730
17 Wiring for Circuit submain 4X4 Sqmm plus 2X4 Sqmm Wiring for circuit submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit as required (Note The item shall be executed as and when required) 4 X 4 sq mm + 2X 4 sq mm earth wire 100 metre engg_hindon 730

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Additional Doc 2 (Requested in ATC)

9

Additional Doc 3 (Requested in ATC)

10

Additional Doc 4 (Requested in ATC)

11

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

12

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Frequently Asked Questions

Key insights about UTTAR PRADESH tender market

What are the eligibility requirements for tendering on operation and comprehensive maintenance for VRF AC systems?

The eligibility requirements include being a registered entity under relevant authorities, demonstrating prior experience in the operation and maintenance of VRF AC systems, possessing all necessary licenses, and ensuring compliance with local laws.

What certificates are required for participating in the VRF AC maintenance tender?

Participants must provide essential certifications such as business registration, applicable licenses for operating maintenance services, and any other relevant compliance documents to ensure eligibility for the tender.

How should participants register for the VRF AC System maintenance tender?

The registration process typically involves filling out the tender application form available from the Airports Authority of India's official website. Participants must submit the required documentation electronically or in hard copy as specified in the tender notification.

What are the expected formats for document submission in this tender?

Accepted document formats usually include PDF and DOC files, though participants are advised to verify specific submission guidelines from the Airports Authority of India’s website or tender documents to ensure compliance.

What benefits are available for Micro, Small, and Medium Enterprises (MSEs) in this tender?

MSEs are encouraged to participate and may receive special provisions in terms of relaxed eligibility criteria, financial assistance, or dedicated support under the 'Make in India' initiative, fostering local industry involvement.