OPERATOR CHAIR_DECK MOUNTED _350130000229_3022_1,OPERATOR CHAIR_DECK MOUNTED _350130000229_3022_2,O
Garden Reach Ship Builders And Engineers Limited (grse)
KOLKATA, WEST BENGAL
Progress
Quantity
127
Category
SITC of 2 nos of 3 TR rated Wall Mounted Split1
Bid Type
Two Packet Bid
Council Of Scientific And Industrial Research (csir) invites bids for SITC of 2 nos of 3 TR rated Wall Mounted Split1, SITC of 2 nos of 3 TR rated Wall Mounted Split2, SITC of 2 nos of 3 TR rated Wall Mounted Split3, SITC of 2 nos of 3 TR rated Wall Mounted Split4, SITC of 2 nos of 3 TR rated Wall Mounted Split5, SITC of 2 nos of 3 TR rated Wall Mounted Split6, SITC of 2 nos of 3 TR rated Wall Mounted Split7, SITC of 2 nos of 3 TR rated Wall Mounted Split8, SITC of 2 nos of 3 TR rated Wall Mounted Split9 in BANGALORE, KARNATAKA. Quantity: 127. Submission Deadline: 11-03-2026 12: 00: 00. Submit your proposal before the deadline.
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Garden Reach Ship Builders And Engineers Limited (grse)
KOLKATA, WEST BENGAL
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | SITC of 2 nos of 3 TR rated Wall Mounted Split1 | Supply Installation Testing and Commissioning of 3TR Sensible cooling capacity of 10.5 KW rated Wall Mounted Split Air Conditioning System having Metal body construction working on 3 PH 415V 50Hz AC Supply Rated for continuous duty 24 7 Energy Efficient EC Electronically mmutated Fan IDU Blower technology with airflow rate 1700 CFM G4 grade air filters SHR Sensible Heat Ratio 90 percent microprocessor based inbuilt sequencing of units based on Duration Cooling Requirement load sharing during failures and remote monitoring features through Modbus SNMP TCP IP etc protocols including first charging of eco friendly Refrigerant Gas as required. | 2 | set | [email protected] | 90 |
| 2 | SITC of 2 nos of 3 TR rated Wall Mounted Split2 | Supply Installation of MS Stand for Outdoor Condenser Unit Floor mounted powder coated MS 25x25x5mm L angle frame including clamps bolts nuts vibrating Dampers as required for mounting as required. | 2 | each | [email protected] | 90 |
| 3 | SITC of 2 nos of 3 TR rated Wall Mounted Split3 | Supply and laying of soft drawn Copper refrigerant pipe of suitable size for 3 TR Air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular Thermal Foam insulation including necessary brazing, jointing etc as required. | 20 | rmt | [email protected] | 90 |
| 4 | SITC of 2 nos of 3 TR rated Wall Mounted Split4 | Supply laying of 4C 2.5 Sqmm FRLS PVC insulated 1.1 kV grade PVC sheathed multistrand flexible Copper Cable confirming to IS 7098 Pt 1 1988 along with the refrigerant lines for Communication cable indoor to outdoor unit | 50 | rmt | [email protected] | 90 |
| 5 | SITC of 2 nos of 3 TR rated Wall Mounted Split5 | Supply laying of 5C 6 Sqmm FRLS PVC insulated 1.1 kV grade PVC sheathed multistrand flexible Copper Cable confirming to IS 7098 Pt 1 1988 for Power Cable | 20 | rmt | [email protected] | 90 |
| 6 | SITC of 2 nos of 3 TR rated Wall Mounted Split6 | Supply and fixing of 25 mm dia SDR 13.5 grade CPVC drain pipe along with accessories and necessary clamps with an U trap at the end as required. | 10 | rmt | [email protected] | 90 |
| 7 | SITC of 2 nos of 3 TR rated Wall Mounted Split7 | Supply laying of Hot dip GI Cable Tray 150 50 1.6mm thick solid bottom cable tray with cover from indoor to outdoor unit for refrigerant, power and control lines. | 20 | rmt | [email protected] | 90 |
| 8 | SITC of 2 nos of 3 TR rated Wall Mounted Split8 | Drilling of hole using core cutting machine of necessary size in wall for laying refrigerant lines etc and finishing the same with cement mortar to match for the surrounding as required after laying as required | 2 | job | [email protected] | 90 |
| 9 | SITC of 2 nos of 3 TR rated Wall Mounted Split9 | Dismantling and shifting of old Cassette split Air Conditioner having indoor and outdoor units, associated refrigerant pipes electrical wires and drain pipes including Pump down of refrigerant Making of necessary alteration to existing grid type False ceiling of tile size 600mm x 600mm to fill up blank space formed after dismantling of Cassette AC units including necessary aluminium channel false ceiling tiles fixing accessories to match for the existing false ceiling as required. | 1 | job | [email protected] | 90 |
Discover companies most likely to bid on this tender
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS