TenderDekho Logo
Active GEM

Procurement Opportunity: Oxygen Concentrator (V2) in MUMBAI, MAHARASHTRA

Bid Publish Date

24-Aug-2026, 12:15 pm

Bid End Date

04-Sep-2026, 1:00 pm

Location

MUMBAI , MAHARASHTRA

Progress

Issue24-Aug-2026, 12:15 pm
AwardPending

Bhabha Atomic Research Centre has released a public tender for Oxygen Concentrator (V2) (Q2) in MUMBAI, MAHARASHTRA. Quantity: 3. Submission Deadline: 04-09-2026 13: 00: 00. Download documents and apply online.

Tender Data

Bid Details

Quantity

3

Bid Type

Two Packet Bid

Bid Validity

90 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

Tech Clarification Time

3 Days

Preference & Exemptions

EMD Required

No

MII Purchase Preference

No

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

MSE Exemption/Relaxation

Yes

Startup Exemption/Relaxation

Yes

Bid Splitting Applied

No

Requirements

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

Oxygen Concentrator (V2) (Q2)

Delivery Details

Max Delivery Days

15

Delivery Locations

1

Delivery Cities

Mumbai Suburban

Delivery Pincodes

400085

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Amit Sharma400085,BHABHA ATOMIC RESEARCH CENTRE (BARC), CENTRAL COMPLEX, TROMBAY, MUMBAI 400085Mumbai SuburbanMaharashtra400085315-

Authority Records

DEPARTMENT OF ATOMIC ENERGY

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 3

GeM-Bidding-9797810.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Authority & Contact

Office Name

Mumbai

Ministry

PMO

Grievance Contact

[email protected]

Categories 3

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
GENERAL Product Description Oxygen Concentrator
PRODUCT INFORMATION Type of Oxygen Concentrator Portable
PRODUCT INFORMATION Maximum Flow Rate 10 LPM
PRODUCT INFORMATION Continuous flow setting 2 LPM
PRODUCT INFORMATION Oxygen Outlet Dual
PRODUCT INFORMATION Oxygen Purity 93% (± 3%)
PRODUCT INFORMATION Outlet pressure (psi) 10 or more
PRODUCT INFORMATION Oxygen Concentration monitor available Yes
PRODUCT INFORMATION Type of operation Continuous Flow Type
PRODUCT INFORMATION Adjustable Air Delivery mechanism Yes
PRODUCT INFORMATION Noise Level (dB) ≤ 10 dB, ≤ 40 db Or higher
PRODUCT INFORMATION Flame Retardant Yes
POWER SOURCE Power Source Electrical Operated
OPERATING TEMPERATURE & HUMIDITY Operating Humidity upto 95%
OPERATING TEMPERATURE & HUMIDITY Operating Altitude Upto 5000 meters Or higher
ALARMS & ALERTS Digital Display Type LCD, LED Or higher
ALARMS & ALERTS Audio Alarm Yes
ALARMS & ALERTS Visual Alarm Yes
ALARMS & ALERTS Alert of technical fault Yes
ALARMS & ALERTS Alert of wrong Battery No
ALARMS & ALERTS Alert of Depleted Battery No
ALARMS & ALERTS Alert of high Breath rate No, Yes
ALARMS & ALERTS Alert of low oxygen purity Yes
ALARMS & ALERTS Alert of No Breath No
ALARMS & ALERTS Alert for No flow Yes
ALARMS & ALERTS Alert for Low flow Yes
ALARMS & ALERTS Alert for High flow Yes
ALARMS & ALERTS Alert of Low Pressure Yes
ALARMS & ALERTS Alert of High Pressure Yes
ALARMS & ALERTS Alert of High temperature Yes
ALARMS & ALERTS Alert for Power failure Yes
ALARMS & ALERTS Alert for service requirement Yes
WARRANTY Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) 1, 2, 3 Or higher
WARRANTY Spare part availability Yes
CERTIFICATION AND REPORTS Compliance to Medical Device Rules (MDR) 2017 as amended till date Yes
CERTIFICATION AND REPORTS Manufacturing unit certification ISO:13485 (Latest)
CERTIFICATION AND REPORTS Availability of Test Report for product as per Medical Device Rules (MDR) 2017 as amended till date Yes
CERTIFICATION AND REPORTS Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement Yes
MISCELLANEOUS REQUIREMENTS OEM/Reseller shall ensure uninterrupted availability of all spares for 10 years Yes
MISCELLANEOUS REQUIREMENTS Availability of toll free facility for technical support maintened by OEM or authorized agencies Yes
MISCELLANEOUS REQUIREMENTS User/Technical/Maintenance manuals to be supplied in English in hard and soft copy Yes
MISCELLANEOUS REQUIREMENTS Details of equipments and procedures required for local calibration and routine maintenance to be supplied and advanced maintenance task documentation also to be furnished Yes
MISCELLANEOUS REQUIREMENTS List of important spares and accessories, with their part numbers to be supplied to the buyer at the time of supplying the equipment Yes
MISCELLANEOUS REQUIREMENTS Installation and Demonstration of equipment and training to be provided after completing supplies before acceptance Yes
MISCELLANEOUS REQUIREMENTS The Principal Manufacturer must have direct Presence/approved service center In India Yes