Quantity

391

Category

HW8421726730

Categories 3

Public procurement opportunity for Bharat Heavy Electricals Limited (bhel) HW8421726730, HW8421726749, HW8421726765, HW8421726773, HW8421726838, HW8421726846, HW8421726854, HW8421726862, HW8421726870, HW8421726919, HW8421726927, HW8421726935, HW8421726943, HW8421726960, HW8421726978, HW8421726986, HW8421726994, HW8421727044, HW8421727052, HW8421727060, HW8421727095, HW8421727109, HW8421727117, HW8421727141, HW8421727150, HW8421727168, HW8421727192, HW8421727214, HW8421727249, HW8421727257, HW8421727265, HW8421727290, HW8421727303, HW8421727311, HW8421727362, HW8421727354, HW8421727346, HW8421727397, HW8421727400, HW8421727419 in HARIDWAR, UTTARAKHAND. Quantity: 391 issued by. Submission Deadline: 15-01-2026 18: 00: 00. View full details and respond.

Bill of Quantities (BOQ) 40 Items

Item # Title Description Quantity Unit Consignee Delivery (Days)
1 HW8421726730 3 POLE AIR BREAK POWER CONTACT -TOR AC-3 CATEGORY,08-10 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 24V DC,AUX. CONTACTS 2NO+2NC, SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 8 no heep_476 120
2 HW8421726749 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,08-10 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 24V AC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 10 no heep_476 120
3 HW8421726765 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,08-10 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 220VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 19 no heep_476 120
4 HW8421726773 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,08-10 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 415VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 12 no heep_476 120
5 HW8421726838 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,11-13 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 24V DC,AUX. CONTACTS 2NO+2NC, SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 6 no heep_476 120
6 HW8421726846 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,11-13 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 24V AC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 20 no heep_476 120
7 HW8421726854 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,11-13 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 110VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 21 no heep_476 120
8 HW8421726862 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,11-13 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 220VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 18 no heep_476 120
9 HW8421726870 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,11-13 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 415VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 9 no heep_476 120
10 HW8421726919 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,15-18 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 24V AC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 14 no heep_476 120
11 HW8421726927 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,15-18 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 110VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 11 no heep_476 120
12 HW8421726935 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,15-18 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 220VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 11 no heep_476 120
13 HW8421726943 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,15-18 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 415VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 10 no heep_476 120
14 HW8421726960 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,22-26 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 24V AC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 12 no heep_476 120
15 HW8421726978 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,22-26 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 110VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 11 no heep_476 120
16 HW8421726986 3 POLE AIR BREAK POWER CONTACT TOR AC-3 CATEGORY,22-26 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 220VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 24 no heep_476 120
17 HW8421726994 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,22-26 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 415VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 15 no heep_476 120
18 HW8421727044 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,30-33 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 110VAC,50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 13 no heep_476 120
19 HW8421727052 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,30-33 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 220VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 27 no heep_476 120
20 HW8421727060 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,30-33 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 415VAC,50HZ,AUX. CONTACTS 2NO+ 2NC,SCREW TERMINAL,STANDARD 35 MM DIN RAIL SNAP FIT MOUNTING & BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 8 no heep_476 120
21 HW8421727095 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,36-42 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 110VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 9 no heep_476 120
22 HW8421727109 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,36-42 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 220VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 14 no heep_476 120
23 HW8421727117 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,36-42 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 415VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 6 no heep_476 120
24 HW8421727141 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,44-50 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 110VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 12 no heep_476 120
25 HW8421727150 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,44-50 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 220VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 11 no heep_476 120
26 HW8421727168 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,44-50 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 415VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 4 no heep_476 120
27 HW8421727192 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,62-66 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 110VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 7 no heep_476 120
28 HW8421727214 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,62-66 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 415VAC 50HZ,AUX. CONTACTS 2NO+ 2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 4 no heep_476 120
29 HW8421727249 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,70-80 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 110V AC 50HZ,AUX. CONTACTS 2NO +2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 6 no heep_476 120
30 HW8421727257 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,70-80 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 220V AC 50HZ,AUX. CONTACTS 2NO +2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 7 no heep_476 120
31 HW8421727265 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,70-80 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 415V AC 50HZ,AUX. CONTACTS 2NO +2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 8 no heep_476 120
32 HW8421727290 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,81-100 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 110V AC 50HZ,AUX. CONTACTS 2NO +2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 8 no heep_476 120
33 HW8421727303 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,81-100 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 220V AC 50HZ,AUX. CONTACTS 2NO +2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 6 no heep_476 120
34 HW8421727311 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,81-100 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 415V AC 50HZ,AUX. CONTACTS 2NO +2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 2 no heep_476 120
35 HW8421727362 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,140-150 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 415V AC 50HZ,AUX. CONTACTS 2NO +2NC, BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 1 no heep_476 120
36 HW8421727354 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,140-150 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 220V AC 50HZ,AUX. CONTACTS 2NO +2NC, BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 1 no heep_476 120
37 HW8421727346 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY,140-150 AMP. AT 415V,50HZ,WITH COIL VOLTAGE 110V AC 50HZ,AUX. CONTACTS 2NO +2NC, BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 1 no heep_476 120
38 HW8421727397 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY, 250-265AMP. AT 415V,50HZ,WITH COIL VOLTAGE 110V AC 50HZ,AUX. CONTACTS 2NO +2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 1 no heep_476 120
39 HW8421727400 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY, 250-265AMP. AT 415V,50HZ,WITH COIL VOLTAGE 220V AC 50HZ,AUX. CONTACTS 2NO +2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 2 no heep_476 120
40 HW8421727419 3 POLE AIR BREAK POWER CONTACT -OR AC-3 CATEGORY, 250-265AMP. AT 415V,50HZ,WITH COIL VOLTAGE 415V AC 50HZ,AUX. CONTACTS 2NO +2NC,BASE MOUNTING,CONFIRMING TO IS/IEC60947-4-1 2 no heep_476 120