Immunoassay Analyzer (V2)
N/a
LUCKNOW, UTTAR PRADESH
Progress
Quantity
1
Bid Type
Single Packet Bid
Hospital Medical Education has released a public tender for Immunoassay Analyzer (V3) (Q2) in AIZAWL, MIZORAM. Quantity: 1. Submission Deadline: 29-07-2026 12: 00: 00. Download documents and apply online.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Immunoassay Analyzer (V3) (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
12
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
45
Delivery Locations
1
Delivery Cities
Aizawl
Delivery Pincodes
796001
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| C.Zothansangi | 796001,Mizoram New Capital Complex (MINECO), Khatla, Aizawl | Aizawl | Mizoram | 796001 | 1 | 45 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
LUCKNOW, UTTAR PRADESH
Assam Medical Services Corporation Limited
KAMRUP, ASSAM
N/a
SURENDRA NAGAR, GUJARAT
N/a
BILASPUR, CHHATTISGARH
Kerala Scheduled Caste Development Department
PALAKKAD, KERALA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| PRODUCT INFORMATION | Type of Configuration | Benchtop |
| PRODUCT INFORMATION | Type of system configuration | Modular |
| PRODUCT INFORMATION | Type of system | Closed |
| PRODUCT INFORMATION | Processing modes | Batch Mode |
| PRODUCT INFORMATION | STAT | Yes, No Or higher |
| PRODUCT INFORMATION | Type of Automation | Fully automated |
| PRODUCT INFORMATION | Throughput of the system per hour | ≥ 100 |
| PRODUCT INFORMATION | Sample Loading Capacity at a time | ≥ 30 |
| PRODUCT INFORMATION | Type of samples | Serum, Plasma, Whole blood, Urine |
| PRODUCT INFORMATION | Sample volume per test in µL | ≥ 1 µL |
| PRODUCT INFORMATION | Type of method | Chemiluminescence (CLIA) |
| Test Menu | Cardiac Markers | Yes |
| Test Menu | Tests which can be performed by Cardiac Markers | CK-MB, Troponin I / Troponin-T, Myoglobin, NT-proBNP, D-Dimer, LP-PLA2, hs-cTnl, Hs - Troponin -I, H-FABP, BNP |
| Test Menu | Infectious Bio Markers | No |
| Test Menu | Tests which can be performed by Bio Markers | NA |
| Test Menu | Tumor Markers | Yes |
| Test Menu | Tests which can be performed by Tumor Markers | AFP, CEA, Total PSA, f-PSA, CA 125, CA 15.3, CA 19-9, CYFRA 21-1, CA 72-4, NSE, SCCA, Pepsinogen I, Pepsinogen II, IL-6, ProGRP, INHIBIN-B |
| Test Menu | Anemia profile | Yes |
| Test Menu | Tests which can be performed by Anemia profile | Vitamin B12, Ferritin, Folate (FA) |
| Test Menu | Bone Metabolism | Yes |
| Test Menu | Tests which can be performed by Bone metabolism | Intact PTH, 25-OH Vitamin D |
| Test Menu | Thyroid profile | Yes |
| Test Menu | Tests which can be performed by thyroid profile | TSH, T4, T3, FT4, FT3, Tg (Thyroglobulin), TGA (Anti - tg), Anti - TPO, Intact PTH |
| Test Menu | Infertility | Yes |
| Test Menu | Tests which can be performed for infertility | FSH, LH, HCG/ß-HCG, PRL, Estradiol, Progesterone, Free Estriol, Testosterone, DHEA - S, AMH |
| Test Menu | Infectious Test | Yes |
| Test Menu | Tests which can be performed for Infectious Test | Anti HCV, HBsAg, HIV Combi, Syphilis, Toxo IgG, Toxo IgM, Rubella IgG, Rubella IgM, CMV IgG, CMV IgM, HSV-1 IgG |
| Test Menu | Dual, Triple or Quad prenatal screening tests | Yes |
| Test Menu | Tests which can be performed for prenatal screening | AFP (prenatal screening), Free ß - HCG, PAPP - A, HCG/ß-HCG, Free Estriol |
| Test Menu | Liver Fibrosis Tests | No |
| Test Menu | Tests which can be performed for Liver Fibrosis | NA |
| Test Menu | Alzheimer Screening | No |
| Test Menu | Tests which can be performed for Alzheimer Screening | NA |
| Test Menu | Neuro Markers | No |
| Test Menu | Tests which can be performed for Neuro Markers | NA |
| Test Menu | Immuno Suppressive drugs | No |
| Test Menu | Tests which can be performed for Immuno Suppressive drugs | NA |
| SYSTEM FEATURES | Closed-tube sampling | Yes, No Or higher |
| SYSTEM FEATURES | Direct tube sampling | Yes Or higher |
| SYSTEM FEATURES | Liquid-level sensing | Yes |
| SYSTEM FEATURES | Clot, Bubble, Viscosity detection | Yes |
| SYSTEM FEATURES | Auto dilution | Yes Or higher |
| SYSTEM FEATURES | Abnormal values flag | Yes Or higher |
| SYSTEM FEATURES | Autowash | Yes Or higher |
| SYSTEM FEATURES | Ultrasonic wash technique to prevent carryover | Yes, No Or higher |
| SYSTEM FEATURES | Disposable tips to prevent any carryover of sample | Yes, No Or higher |
| SYSTEM FEATURES | Both quantitative and qualitative analysis of results | Yes Or higher |
| SYSTEM FEATURES | Inbuilt facility for reagent mixing | Yes Or higher |
| SYSTEM FEATURES | Availability of inbuilt refrigeration system for long onboard stability of reagents | Yes Or higher |
| SYSTEM FEATURES | Module for reading reagents | Barcode scanner |
| SYSTEM FEATURES | Facility to collect both solid and liquid waste for disposal | Yes |
| SYSTEM FEATURES | Type of Calibration | Manual |
| SYSTEM FEATURES | Calibration stability | ≥ 14 |
| SYSTEM FEATURES | LOT specific calibration | Yes Or higher |
| SYSTEM FEATURES | Should have inbuilt quality control system to monitor the quality results obtained and LJ charts must be visible | Yes Or higher |
| DATA MANAGEMENT | Type of data management | In-built system |
| DATA MANAGEMENT | Type of display | LED/LCD/TFT |
| DATA MANAGEMENT | Size of Display in inches | ≥ 10 Inches |
| DATA MANAGEMENT | Touch Screen display | Yes |
| DATA MANAGEMENT | Handheld barcode reader | Yes |
| DATA MANAGEMENT | HIS/LIS Interface | Ethernet |
| DATA MANAGEMENT | Data Storage of sample | 1000 or more |
| DATA MANAGEMENT | Should be provided with inbuilt/external printer with necessary accessories | Yes |
| DATA MANAGEMENT | Type of External storage | USB |
| ACCESSORIES | Startup Reagent Kit to be provided | Yes |
| ACCESSORIES | Two set of all tubings | Yes, No Or higher |
| ACCESSORIES | Alerts for operator for level of reagents and to empty waste when indicated | Yes Or higher |
| POWER REQUIREMENTS | Type of power supply in VAC,Hz | 200-240 VAC, 50-60 Hz |
| POWER REQUIREMENTS | UPS Backup in minutes | NA if UPS not provided |
| CERTIFICATION AND REPORTS | Compliance to Drugs and Cosmetic Act 1940 and Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATION AND REPORTS | Availability of valid Medical Device license for the product issued from the competent authority | Yes |
| CERTIFICATION AND REPORTS | License issuing authority as per MDR | Central Licensing Authority |
| WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 1 Year |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
N/a
📍 CENTRAL DELHI, DELHI
N/a
📍 CENTRAL DELHI, DELHI
Employees State Insurance Corporation
📍 HYDERABAD, TELANGANA
Employees State Insurance Corporation
📍 VALSAD, GUJARAT
N/a
📍 PONDICHERRY, PUDUCHERRY
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS