Electrocardiography (ECG) Machine (V2)
Patan District Panchayat
PATAN, GUJARAT
Bid Publish Date
09-Feb-2026, 11:34 am
Bid End Date
02-Mar-2026, 2:00 pm
Progress
Quantity
1
Bid Type
Single Packet Bid
Directorate Of Purchase And Stores announces a tender for Electrocardiography (ECG) Machine (V2) (Q2). Quantity: 1. Submission Deadline: 02-03-2026 14: 00: 00. Last date to apply is approaching fast!
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Patan District Panchayat
PATAN, GUJARAT
Ntpc Limited
CHATRA, JHARKHAND
N/a
Sree Chitra Tirunal Institute For Medical Sciences And Technology (sctimst)
THIRUVANANTHAPURAM, KERALA
Health Services
AIZAWL, MIZORAM
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL FEATURES | Product Description | ECG Machine |
| PRODUCT INFORMATION | Operating modes of ECG Machine | Automatic, Manual and Rhythm |
| PRODUCT INFORMATION | ECG machine should have ECG lead annotation facility | Yes |
| PRODUCT INFORMATION | Leads which is in ECG machine should be able to acquire simultaneously and interpret them | 12 |
| PRODUCT INFORMATION | Number of channels | 12 Channel |
| PRODUCT INFORMATION | ECG machine should acquire lead ECG for both adult and pediatric patients | Yes |
| PRODUCT INFORMATION | The ECG machine should have facility to show lead fail indication | Yes |
| PRODUCT INFORMATION | The ECG machine should have facility to show lead reversal indication | Yes |
| PRODUCT INFORMATION | The ECG machine should have facility to show the impedance to quality check of connection | Yes |
| PRODUCT INFORMATION | Acquisition time for ECG Machine in sec | 10 sec |
| PRODUCT INFORMATION | Digital sampling rate for Pacemaker spike detection | 8000 s/sec/channel |
| PRODUCT INFORMATION | Recording of digital sampling for pacemaker | 1000 s/sec/channel |
| PRODUCT INFORMATION | ECG machine should have real time colour backlit display of ECG waveforms with signal qualify indication for each lead | Yes |
| PRODUCT INFORMATION | ECG machine should have frequency filters | Artifact, AC and low and high pass frequency filters |
| PRODUCT INFORMATION | Number of ECGs which can be store in ECG Machine | 151 to 200 |
| PRODUCT INFORMATION | ECG machine should have full screen preview of ECG report for quality assessment checks prior to print | Yes |
| PRODUCT INFORMATION | Type of inbuilt screen | LCD |
| PRODUCT INFORMATION | Size of screen in inches | 5 |
| PRODUCT INFORMATION | Display resolution of ECG machine in pixels | 640 x 480 |
| PRODUCT INFORMATION | ECG machine should have interpretation facility of the amplitudes, duration and morphologies of ECG waveforms and associated rhythm for adult and pediatric patient | Yes |
| PRODUCT INFORMATION | ECG machine should have alphanumeric keyboard for patient data entry | Hard keys |
| PRODUCT INFORMATION | Availability of latest interpretation software | No |
| PRODUCT INFORMATION | Wireless acquisition module with RF technology | No |
| PRODUCT INFORMATION | System should have the dedicated software to download the ECG form machine in PDF format | Yes |
| PRINTER | Printer Type | Thermal Printer |
| PRINTER | Recorder Paper Size | A4 Size |
| PRINTER | Recorder Speed | 50 mm/sec |
| PRINTER | Resolution of digital array printer | 200 dpi x 500 dpi |
| PRINTER | Number of Thermal paper | 500, 1000 Or higher |
| PRINTER | ECG machine report format | Report formats of 3x4, 6x2, Rhythm for up to selected leads, 12 lead extended measurement, 1 minute of continuous waveform data for 1 selected lead |
| BATTERY | Provision of Battery | Yes |
| BATTERY | Battery Type | Built in Rechargeable Battery |
| BATTERY | Battery capacity of continuous rhythm recording on single charge (minutes) | 60 |
| BATTERY | Battery capacity | 50 ECG or 1 hour of continous rhythm recording on single charge |
| BATTERY | Connectivity to ECG Machine | LAN |
| BATTERY | The individual patient lead should be change without replacing the whole patient cable assembly | Yes |
| ENVIRONNMENTS PARAMETERS | Operating temperature and humidity | Temperature of 10 to 40 degree Celsius and Relative Humidity of 15 to 90% |
| POWER SUPPLY | Power input | 220-240 V AC, 50 Hz fitted with Indian plug |
| ACCESSORIES | ECG Machine 12 leads with interpretation | 1 |
| ACCESSORIES | Patient Cable | 2 |
| ACCESSORIES | Chest Electrodes Adult (set of Six) | 1 |
| ACCESSORIES | Chest Electrodes Paediatric (set of Six) | Not provided |
| ACCESSORIES | Limb Electrodes | 2 for adults and 2 for paediatric |
| ACCESSORIES | Power cable for charging | Yes |
| ACCESSORIES | Supplied with Clip electrode | Yes |
| ACCESSORIES | Compatible trolley provided | No |
| CERTIFICATION & REPORTS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATION & REPORTS | Availability of valid drug license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATION & REPORTS | Manufacturing unit certification | ISO:13485 (Latest) |
| CERTIFICATION & REPORTS | Availability of Test Report for each supplied batch/product as per Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATION & REPORTS | Compliance to Safety Standards | IS 13450:Part 2:Sec 25 / IEC 60601-2-25 |
| CERTIFICATION & REPORTS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement | Yes |
| WARRANTY | Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5 Or higher |
| Miscellaneous Parameters | User/Technical/Maintenance manuals to be supplied in English in hard and soft copy | Yes |
| Miscellaneous Parameters | The Principal Manufacturer must have direct Presence/approved service center In India | Yes |
| Miscellaneous Parameters | Installation and demonstration of equipment and training to be provided after completing supplies before acceptance | Yes |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
02-Mar-2026, 2:00 pm
Opening Date
02-Mar-2026, 2:30 pm
N/a
📍 LUCKNOW, UTTAR PRADESH
N/a
📍 RAICHUR, KARNATAKA
Gail India Limited
📍 RAIGAD, MAHARASHTRA
Sign up now to access all documents
Main Document
CATALOG Specification
ATC