Bid Publish Date
03-Sep-2026, 4:23 pm
Bid End Date
18-Sep-2026, 4:00 pm
EMD
₹2,99,343
Value
₹1,49,67,164
Location
Progress
Public procurement opportunity for Airports Authority Of India Refer SOQ Sl. No. 1. Supply of outdoor Bullet Camera, Refer SOQ Sl. No. 2. Supply of Indoor Dome Cam in IMPHAL WEST, MANIPUR. Quantity: 12010 issued by. Submission Deadline: 18-09-2026 16: 00: 00. View full details and respond.
Quantity
12010
Category
Refer SOQ Sl. No. 4. Supply of Server Hardware for VMS
Bid Type
Two Packet Bid
Bid Validity
90 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Min. Avg. Annual Turnover
45
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Advisory Bank
State Bank of India
Payment Timelines
Payments shall be made to the Seller within 30 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
90
Delivery Locations
1
Delivery Cities
Imphal West
Delivery Pincodes
795140
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Semreichui Duidang | 795140,O/o Airport Director, Airports Authority of India, Imphal Airport | Imphal West | Manipur | 795140 | 5 | 90 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Refer SOQ Sl. No. 1. Supply of outdoor Bullet Camera
Refer SOQ Sl. No. 1. Supply of outdoor Bullet Camera
Refer SOQ Sl. No. 2. Supply of Indoor Dome Camera
Refer SOQ Sl. No. 2. Supply of Indoor Dome Camera
Refer SOQ Sl. No. 3. Supply of Outdoor PTZ Camera
Refer SOQ Sl. No. 3. Supply of Outdoor PTZ Camera
Refer SOQ Sl. No. 4. Supply of Server Hardware for VMS
Supply of Server Hardware for VMS, as per technical specification.
Refer SOQ Sl. No. 5. Supply of Desktop KVM switch including Display 19 inches or higher, Keyboard, Mouse
Supply of Desktop KVM switch including Display 19 inches or higher, Keyboard, Mouse as per technical specification.
Refer SOQ Sl. No. 6. Supply of Video Management Software as Base Software
Supply of Video Management Software as Base Software as per technical specification.
Refer SOQ Sl. No. 7. Supply of Connecting Camera License for Video Management Software
Supply of Connecting Camera License for Video Management Software as per technical specification.
Refer SOQ Sl. No. 8. Supply of Client Work Station for Control room and Live View including Display Unit 55 inchese
Supply of Client Work Station for Control room and Live View including Display Unit 55 inchese as per technical specification.
Refer SOQ Sl. No. 9. Supply of Video Recording Storage for min 30 Days Recording of all cameras
Supply of Video Recording Storage for min 30 Days Recording of all cameras as per technical specification.
Refer SOQ Sl. No. 10. Supply of 24 Port, L3 switch, Gigabit PoE Plus with 4 x 10G SFP Slot, Manage Switch
Supply of 24 Port, L3 switch, Gigabit PoE Plus with 4 x 10G SFP Slot, Manage Switch as per technical specification.
Refer SOQ Sl. No. 11. Supply of 16 Port Gigabit PoE Plus with 4 x 10G SFP Slot
Supply of 16 Port Gigabit PoE Plus with 4 x 10G SFP Slot as per technical specification.
Refer SOQ Sl. No. 12. Supply of 12 Port Fiber Patch Panel, LIU, Fully Loaded SC Type
Supply of 12 Port Fiber Patch Panel, LIU, Fully Loaded SC Type as per technical specification.
Refer SOQ Sl. No. 13. Supply of 8 Port Gigabit PoE with 2 x 10G SFP Slot Industrial Grade Switch
Supply of 8 Port Gigabit PoE with 2 x 10G SFP Slot Industrial Grade Switch as per technical specification.
Refer SOQ Sl. No. 14. Supply of 6 Core Single Mode Armoured Optical Fibre Cable
Supply of 6 Core Single Mode Armoured Optical Fibre Cable as per technical specification.
Refer SOQ Sl. No. 15. Supply of Optical Fiber Patch Cord-SC-LC
Supply of Optical Fiber Patch Cord-SC-LC as per technical specification.
Refer SOQ Sl. No. 16. Supply of Cat 6, 4 Pair Unshielded Twisted Pair Cable - LSZH, Indoor Purpose
Supply of Cat 6, 4 Pair Unshielded Twisted Pair Cable - LSZH, Indoor Purpose as per technical specification.
Refer SOQ Sl. No. 17. Supply of Cat 6, 4 Pair Shielded Twisted Pair Cable - LSZH, Outdoor Purpose
Supply of Cat 6, 4 Pair Shielded Twisted Pair Cable - LSZH, Outdoor Purpose as per technical specification.
Refer SOQ Sl. No. 18. Supply of Cat 6, 24 Port UTP Patch Panel
Supply of Cat 6, 24 Port UTP Patch Panel as per technical specification.
Refer SOQ Sl. No. 19. Supply of Cat 6, UTP Patch Cord - 1 Mtr
Supply of Cat 6, UTP Patch Cord - 1 Mtr as per technical specification.
Refer SOQ Sl. No. 20. Supply of 22U Floor Mount Network Rack at Control Room
Supply of 22U Floor Mount Network Rack at Control Room as per Technical Specification.
Refer SOQ Sl. No. 21. Supply of 9U Wall Mount Network Rack
Supply of 9U Wall Mount Network Rack as per Technical Specification.
Refer SOQ Sl. No. 22. Supply of 6U Pole Mount Rack, Outdoor Purpose
Supply of 6U Pole Mount Rack, Outdoor Purpose as per Technical Specification.
Refer SOQ Sl. No. 23. Supply of GI Pole 6m, minimum 80mm dia. medium class with base plate for mounting the camera
Supply of GI Pole 6m, minimum 80mm dia. medium class with base plate for mounting the camera as per technical specification.
Refer SOQ Sl. No. 24. Supply of 6KVA N plus 1 Online UPS, 3in - 1out, with SMF batteries, 30 Min Backup each
Supply of 6KVA N plus 1 Online UPS, 3in - 1out, with SMF batteries, 30 Min Backup each as per technical specification. 2 Nos UPS with Batteries is equal to 1 Set which will function as N plus 1
Refer SOQ Sl. No. 25. Supply of 1.1 kV, 3 x 2.5 sq.mm FRLS PVC insulated industrial copper conductor cable
Supply of 1.1 kV, 3 x 2.5 sq.mm FRLS PVC insulated industrial copper conductor cable.
Refer SOQ Sl. No. 26. Supply of 63 Amp MCB with enclosure For UPS End
Supply of 63 Amp MCB with enclosure For UPS End.
Refer SOQ Sl. No. 27. Supply of Media converter, 2 port RJ45.
Supply of Media converter, 2 port RJ45.
Refer SOQ Sl. No. 28. Supply of 16 Amp MCB with enclosure For Rack End
Supply of 16 Amp MCB with enclosure For Rack End.
Refer SOQ Sl. No. 29. Supply of 32mm HDPE Pipe - PN6PE63
Supply of 32 mm High Density Polyethylene Pipe - PN6PE63 as per technical specification.
Refer SOQ Sl. No. 30. Supply of 25 mm dia. MS Conduit as per technical specification
Supply of 25 mm dia. MS Conduit as per technical specification.
Refer SOQ Sl. No. 31. Laying of High Density Polyethylene Pipe on surface
Laying of High Density Polyethylene Pipe on surface
Refer SOQ Sl. No. 32. Laying of High Density Polyethylene Pipe Underground at a depth of 75cm
Laying of High Density Polyethylene Pipe Underground at a depth of 75 cm
Refer SOQ Sl. No. 33. Laying, fixing of MS Conduit on or above of false celling or fixing on wall including fixing of suitable saddle and screws etc.
Laying and fixing of MS Conduit on or above of false celling or fixing on wall including fixing of suitable saddle and screws etc.
Refer SOQ Sl. No. 34. Laying of Optical Fibre Cable Through HDPE Conduit complete as required
Laying of Optical Fibre Cable Through HDPE Conduit complete as required.
Refer SOQ Sl. No. 35. Laying of Cat6 UTP Through MS Conduit complete as required
Laying of Cat6 UTP Through MS Conduit complete as required.
Refer SOQ Sl. No. 36. Laying of Cat6 STP Through MS Conduit complete as required
Laying of Cat6 STP Through MS Conduit complete as required.
Refer SOQ Sl. No. 37. Laying of Electrical Cable Through MS Conduit complete as required
Laying of Electrical Cable Through MS Conduit complete as required.
Refer SOQ Sl. No. 38. Mounting, Fixing and Dressing of All types of LIU complete as required
Mounting, Fixing and Dressing of All types of LIU complete as required.
Refer SOQ Sl. No. 39. Splicing of Optical Fibre Cable complete as required
Splicing of Optical Fibre Cable complete as required.
Refer SOQ Sl. No. 40. Mounting and Fixing of GI Pole after excavation of soft or hard soil including cutting of bituminous road or pavement
Mounting and Fixing of GI Pole after excavation of soft or hard soil including cutting of bituminous road or pavement up to desired depth and making suitable foundation for erection of the GI pole complete as required.
Refer SOQ Sl. No. 41. Mounting, Fixing and Dressing of Floor Standing Rack complete as required
Mounting, Fixing and Dressing of Floor Standing Rack complete as required.
Refer SOQ Sl. No. 42. Mounting, Fixing and Dressing of Wall Mount Rack complete as required
Mounting, Fixing and Dressing of Wall Mount Rack complete as required.
Refer SOQ Sl. No. 43. Mounting, Fixing and Dressing of Pole Mount Rack complete as required
Mounting, Fixing and Dressing of Pole Mount Rack complete as required.
Refer SOQ Sl. No. 44. Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All Types of Cameras
Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All Types of Cameras complete as required.
Refer SOQ Sl. No. 45. Mounting, Fixing, Installation, Configuration, Testing and Commissioning of Server
Mounting, Fixing, Installation, Configuration, Testing and Commissioning of Server complete as required.
Refer SOQ Sl. No. 46. Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All types of Workstation including display
Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All types of Workstation including display complete as required.
Refer SOQ Sl. No. 47. Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All Types of Switches
Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All Types of Switches complete as required.
Refer SOQ Sl. No. 48. Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All Types of Media Converter
Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All Types of Media Converter complete as required.
Refer SOQ Sl. No. 49. Mounting, Fixing, Installation, Configuration, Testing and Commissioning of UPS System
Mounting, Fixing, Installation, Configuration, Testing and Commissioning of UPS System complete as required.
Refer SOQ Sl. No. 50. Installation, Configuration, Testing and Commissioning of VMS Software
Installation, Configuration, Testing and Commissioning of VMS Software complete as required.
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Refer SOQ Sl. No. 1. Supply of outdoor Bullet Camera | Refer SOQ Sl. No. 1. Supply of outdoor Bullet Camera | 5 | nos | buycon147.aai.mn | 90 | |
| 2 | Refer SOQ Sl. No. 2. Supply of Indoor Dome Camera | Refer SOQ Sl. No. 2. Supply of Indoor Dome Camera | 20 | nos | buycon147.aai.mn | 90 | |
| 3 | Refer SOQ Sl. No. 3. Supply of Outdoor PTZ Camera | Refer SOQ Sl. No. 3. Supply of Outdoor PTZ Camera | 9 | nos | buycon147.aai.mn | 90 | |
| 4 | Refer SOQ Sl. No. 4. Supply of Server Hardware for VMS | Supply of Server Hardware for VMS, as per technical specification. | 2 | nos | buycon147.aai.mn | 90 | |
| 5 | Refer SOQ Sl. No. 5. Supply of Desktop KVM switch including Display 19 inches or higher, Keyboard, Mouse | Supply of Desktop KVM switch including Display 19 inches or higher, Keyboard, Mouse as per technical specification. | 1 | no | buycon147.aai.mn | 90 | |
| 6 | Refer SOQ Sl. No. 6. Supply of Video Management Software as Base Software | Supply of Video Management Software as Base Software as per technical specification. | 1 | no | buycon147.aai.mn | 90 | |
| 7 | Refer SOQ Sl. No. 7. Supply of Connecting Camera License for Video Management Software | Supply of Connecting Camera License for Video Management Software as per technical specification. | 40 | nos | buycon147.aai.mn | 90 | |
| 8 | Refer SOQ Sl. No. 8. Supply of Client Work Station for Control room and Live View including Display Unit 55 inchese | Supply of Client Work Station for Control room and Live View including Display Unit 55 inchese as per technical specification. | 4 | nos | buycon147.aai.mn | 90 | |
| 9 | Refer SOQ Sl. No. 9. Supply of Video Recording Storage for min 30 Days Recording of all cameras | Supply of Video Recording Storage for min 30 Days Recording of all cameras as per technical specification. | 1 | no | buycon147.aai.mn | 90 | |
| 10 | Refer SOQ Sl. No. 10. Supply of 24 Port, L3 switch, Gigabit PoE Plus with 4 x 10G SFP Slot, Manage Switch | Supply of 24 Port, L3 switch, Gigabit PoE Plus with 4 x 10G SFP Slot, Manage Switch as per technical specification. | 1 | no | buycon147.aai.mn | 90 | |
| 11 | Refer SOQ Sl. No. 11. Supply of 16 Port Gigabit PoE Plus with 4 x 10G SFP Slot | Supply of 16 Port Gigabit PoE Plus with 4 x 10G SFP Slot as per technical specification. | 4 | nos | buycon147.aai.mn | 90 | |
| 12 | Refer SOQ Sl. No. 12. Supply of 12 Port Fiber Patch Panel, LIU, Fully Loaded SC Type | Supply of 12 Port Fiber Patch Panel, LIU, Fully Loaded SC Type as per technical specification. | 6 | mtr | buycon147.aai.mn | 90 | |
| 13 | Refer SOQ Sl. No. 13. Supply of 8 Port Gigabit PoE with 2 x 10G SFP Slot Industrial Grade Switch | Supply of 8 Port Gigabit PoE with 2 x 10G SFP Slot Industrial Grade Switch as per technical specification. | 1 | no | buycon147.aai.mn | 90 | |
| 14 | Refer SOQ Sl. No. 14. Supply of 6 Core Single Mode Armoured Optical Fibre Cable | Supply of 6 Core Single Mode Armoured Optical Fibre Cable as per technical specification. | 1,000 | mtr | buycon147.aai.mn | 90 | |
| 15 | Refer SOQ Sl. No. 15. Supply of Optical Fiber Patch Cord-SC-LC | Supply of Optical Fiber Patch Cord-SC-LC as per technical specification. | 12 | nos | buycon147.aai.mn | 90 | |
| 16 | Refer SOQ Sl. No. 16. Supply of Cat 6, 4 Pair Unshielded Twisted Pair Cable - LSZH, Indoor Purpose | Supply of Cat 6, 4 Pair Unshielded Twisted Pair Cable - LSZH, Indoor Purpose as per technical specification. | 1,500 | mtr | buycon147.aai.mn | 90 | |
| 17 | Refer SOQ Sl. No. 17. Supply of Cat 6, 4 Pair Shielded Twisted Pair Cable - LSZH, Outdoor Purpose | Supply of Cat 6, 4 Pair Shielded Twisted Pair Cable - LSZH, Outdoor Purpose as per technical specification. | 900 | mtr | buycon147.aai.mn | 90 | |
| 18 | Refer SOQ Sl. No. 18. Supply of Cat 6, 24 Port UTP Patch Panel | Supply of Cat 6, 24 Port UTP Patch Panel as per technical specification. | 6 | nos | buycon147.aai.mn | 90 | |
| 19 | Refer SOQ Sl. No. 19. Supply of Cat 6, UTP Patch Cord - 1 Mtr | Supply of Cat 6, UTP Patch Cord - 1 Mtr as per technical specification. | 40 | nos | buycon147.aai.mn | 90 | |
| 20 | Refer SOQ Sl. No. 20. Supply of 22U Floor Mount Network Rack at Control Room | Supply of 22U Floor Mount Network Rack at Control Room as per Technical Specification. | 1 | no | buycon147.aai.mn | 90 | |
| 21 | Refer SOQ Sl. No. 21. Supply of 9U Wall Mount Network Rack | Supply of 9U Wall Mount Network Rack as per Technical Specification. | 4 | nos | buycon147.aai.mn | 90 | |
| 22 | Refer SOQ Sl. No. 22. Supply of 6U Pole Mount Rack, Outdoor Purpose | Supply of 6U Pole Mount Rack, Outdoor Purpose as per Technical Specification. | 3 | nos | buycon147.aai.mn | 90 | |
| 23 | Refer SOQ Sl. No. 23. Supply of GI Pole 6m, minimum 80mm dia. medium class with base plate for mounting the camera | Supply of GI Pole 6m, minimum 80mm dia. medium class with base plate for mounting the camera as per technical specification. | 3 | nos | buycon147.aai.mn | 90 | |
| 24 | Refer SOQ Sl. No. 24. Supply of 6KVA N plus 1 Online UPS, 3in - 1out, with SMF batteries, 30 Min Backup each | Supply of 6KVA N plus 1 Online UPS, 3in - 1out, with SMF batteries, 30 Min Backup each as per technical specification. 2 Nos UPS with Batteries is equal to 1 Set which will function as N plus 1 | 1 | set | buycon147.aai.mn | 90 | |
| 25 | Refer SOQ Sl. No. 25. Supply of 1.1 kV, 3 x 2.5 sq.mm FRLS PVC insulated industrial copper conductor cable | Supply of 1.1 kV, 3 x 2.5 sq.mm FRLS PVC insulated industrial copper conductor cable. | 600 | mtr | buycon147.aai.mn | 90 | |
| 26 | Refer SOQ Sl. No. 26. Supply of 63 Amp MCB with enclosure For UPS End | Supply of 63 Amp MCB with enclosure For UPS End. | 4 | nos | buycon147.aai.mn | 90 | |
| 27 | Refer SOQ Sl. No. 27. Supply of Media converter, 2 port RJ45. | Supply of Media converter, 2 port RJ45. | 4 | nos | buycon147.aai.mn | 90 | |
| 28 | Refer SOQ Sl. No. 28. Supply of 16 Amp MCB with enclosure For Rack End | Supply of 16 Amp MCB with enclosure For Rack End. | 8 | nos | buycon147.aai.mn | 90 | |
| 29 | Refer SOQ Sl. No. 29. Supply of 32mm HDPE Pipe - PN6PE63 | Supply of 32 mm High Density Polyethylene Pipe - PN6PE63 as per technical specification. | 900 | mtr | buycon147.aai.mn | 90 | |
| 30 | Refer SOQ Sl. No. 30. Supply of 25 mm dia. MS Conduit as per technical specification | Supply of 25 mm dia. MS Conduit as per technical specification. | 1,000 | mtr | buycon147.aai.mn | 90 | |
| 31 | Refer SOQ Sl. No. 31. Laying of High Density Polyethylene Pipe on surface | Laying of High Density Polyethylene Pipe on surface | 770 | mtr | buycon147.aai.mn | 90 | |
| 32 | Refer SOQ Sl. No. 32. Laying of High Density Polyethylene Pipe Underground at a depth of 75cm | Laying of High Density Polyethylene Pipe Underground at a depth of 75 cm | 130 | mtr | buycon147.aai.mn | 90 | |
| 33 | Refer SOQ Sl. No. 33. Laying, fixing of MS Conduit on or above of false celling or fixing on wall including fixing of suitable saddle and screws etc. | Laying and fixing of MS Conduit on or above of false celling or fixing on wall including fixing of suitable saddle and screws etc. | 1,000 | mtr | buycon147.aai.mn | 90 | |
| 34 | Refer SOQ Sl. No. 34. Laying of Optical Fibre Cable Through HDPE Conduit complete as required | Laying of Optical Fibre Cable Through HDPE Conduit complete as required. | 900 | mtr | buycon147.aai.mn | 90 | |
| 35 | Refer SOQ Sl. No. 35. Laying of Cat6 UTP Through MS Conduit complete as required | Laying of Cat6 UTP Through MS Conduit complete as required. | 1,500 | mtr | buycon147.aai.mn | 90 | |
| 36 | Refer SOQ Sl. No. 36. Laying of Cat6 STP Through MS Conduit complete as required | Laying of Cat6 STP Through MS Conduit complete as required. | 900 | mtr | buycon147.aai.mn | 90 | |
| 37 | Refer SOQ Sl. No. 37. Laying of Electrical Cable Through MS Conduit complete as required | Laying of Electrical Cable Through MS Conduit complete as required. | 600 | mtr | buycon147.aai.mn | 90 | |
| 38 | Refer SOQ Sl. No. 38. Mounting, Fixing and Dressing of All types of LIU complete as required | Mounting, Fixing and Dressing of All types of LIU complete as required. | 6 | nos | buycon147.aai.mn | 90 | |
| 39 | Refer SOQ Sl. No. 39. Splicing of Optical Fibre Cable complete as required | Splicing of Optical Fibre Cable complete as required. | 60 | nos | buycon147.aai.mn | 90 | |
| 40 | Refer SOQ Sl. No. 40. Mounting and Fixing of GI Pole after excavation of soft or hard soil including cutting of bituminous road or pavement | Mounting and Fixing of GI Pole after excavation of soft or hard soil including cutting of bituminous road or pavement up to desired depth and making suitable foundation for erection of the GI pole complete as required. | 3 | nos | buycon147.aai.mn | 90 | |
| 41 | Refer SOQ Sl. No. 41. Mounting, Fixing and Dressing of Floor Standing Rack complete as required | Mounting, Fixing and Dressing of Floor Standing Rack complete as required. | 1 | no | buycon147.aai.mn | 90 | |
| 42 | Refer SOQ Sl. No. 42. Mounting, Fixing and Dressing of Wall Mount Rack complete as required | Mounting, Fixing and Dressing of Wall Mount Rack complete as required. | 4 | nos | buycon147.aai.mn | 90 | |
| 43 | Refer SOQ Sl. No. 43. Mounting, Fixing and Dressing of Pole Mount Rack complete as required | Mounting, Fixing and Dressing of Pole Mount Rack complete as required. | 3 | nos | buycon147.aai.mn | 90 | |
| 44 | Refer SOQ Sl. No. 44. Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All Types of Cameras | Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All Types of Cameras complete as required. | 34 | nos | buycon147.aai.mn | 90 | |
| 45 | Refer SOQ Sl. No. 45. Mounting, Fixing, Installation, Configuration, Testing and Commissioning of Server | Mounting, Fixing, Installation, Configuration, Testing and Commissioning of Server complete as required. | 2 | nos | buycon147.aai.mn | 90 | |
| 46 | Refer SOQ Sl. No. 46. Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All types of Workstation including display | Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All types of Workstation including display complete as required. | 4 | nos | buycon147.aai.mn | 90 | |
| 47 | Refer SOQ Sl. No. 47. Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All Types of Switches | Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All Types of Switches complete as required. | 6 | nos | buycon147.aai.mn | 90 | |
| 48 | Refer SOQ Sl. No. 48. Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All Types of Media Converter | Mounting, Fixing, Installation, Configuration, Testing and Commissioning of All Types of Media Converter complete as required. | 4 | nos | buycon147.aai.mn | 90 | |
| 49 | Refer SOQ Sl. No. 49. Mounting, Fixing, Installation, Configuration, Testing and Commissioning of UPS System | Mounting, Fixing, Installation, Configuration, Testing and Commissioning of UPS System complete as required. | 1 | no | buycon147.aai.mn | 90 | |
| 50 | Refer SOQ Sl. No. 50. Installation, Configuration, Testing and Commissioning of VMS Software | Installation, Configuration, Testing and Commissioning of VMS Software complete as required. | 1 | no | buycon147.aai.mn | 90 |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer