Bid Publish Date
27-Nov-2025, 5:16 pm
Bid End Date
08-Dec-2025, 3:00 pm
Location
Progress
Quantity
105
Category
3-POLE MOULDED CASE CIRCUIT BREAKER 250A
Bid Type
Two Packet Bid
Visvesvaraya Iron And Steel Plant (a constituent unit of Steel Authority of India Limited) invites bids for the supply of electrical protection devices including MPCB-rated breakers, MCCBs, and circuit breakers for roller tables and backwash pumps. The scope is limited to the supply of goods, with an estimated project scale implied by multiple item categories (11 items in the BOQ, though detailed quantities are not disclosed). The delivery schedule requires completion within 2 months from PO, indicating a fast-track procurement for critical electrical protection equipment. The tender emphasizes compliance with GST and vendor-code creation prerequisites, and requests standard supplier documents (PAN, GSTIN, cancelled cheque, EFT mandate). This procurement appears to target maintenance or upgrade of existing electrical protection systems across multiple amperage ratings and 50KA fault-current withstand, aligning with plant safety and reliability needs. Unique aspects include the explicit delivery window and the mandatory bidder documentation for supplier onboarding, with ATC references to the uploaded technical specifications file for itemized quantities and delivery milestones.
Delivery within 2 months from PO; ensure timely shipment
GST treatment as per actuals with cap; bidder bears GST rate
Invoices must be GST-compliant and in consignee name with GSTIN
Provide PAN, GSTIN, cancelled cheque, and EFT mandate
Consult uploaded ATC for exact quantities and technical specs
GST reimbursement as per actuals or applicable rates; bidder bears GST; payment evidence via GST portal
Delivery to be completed within 2 months from PO; milestones as per ATC
Not specified in public data; confirm in ATC/document portal
Must have GST registration and valid PAN
Must submit EFT Mandate and bank-certified PPO
Must conform to vendor-code creation requirements and reference ATC for technical specs
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
MPCB RATING 4-6 point 3 AMPS 50KA , MPCB RATING 6-10 AMPS 50KA , MPCB RATING 10-16 AMPS 50KA , MPCB RATING 16-20 AMPS , MPCB RATING 20-25 AMPS 50KA , MPCB RATING 25-32 AMPS 50KA , MPCB RATING 28-40 AMPS 50KA , CKT BREAKER FOR ROLLER TABLES GRP DRIVE , MCCBs THER RAT 100A WITH 56 percent PLUG SETTING , CKT BREAKER FOR and HE BACKWASH PUMPS 160A , 3- POLE MOULDED CASE CIRCUIT BREAKER 250A
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
MPCB RATING 4-6 point 3 AMPS 50KA
MPCB RATING 4-6 point 3 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 4 to 6 point 3 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism-Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no of the offered item along with offer 3- OEM should be ISO certified company
MPCB RATING 6-10 AMPS 50KA
MPCB RATING 6-10 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 6 to 10 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism- Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no of the offered item along with offer 3- OEM should be ISO certified company
MPCB RATING 10-16 AMPS 50KA
MPCB RATING 10-16 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 10 to 16 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism- Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no of the offered item along with offer 3- OEM should be ISO certified company
MPCB RATING 16-20 AMPS
MPCB RATING 16-20 AMPS 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 16 to 20 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism- Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no. of the offered item along with offer 3- OEM should be ISO certified company
MPCB RATING 20-25 AMPS 50KA
MPCB RATING 20-25 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 20 to 25 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism- Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no. of the offered item along with offer 3- OEM should be ISO certified company
MPCB RATING 25-32 AMPS 50KA
MPCB RATING 25-32 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 25 to 32 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism- Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no of the offered item along with offer 3- OEM should be ISO certified company
MPCB RATING 28-40 AMPS 50KA
MPCB RATING 28-40 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 28 to 40 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism- Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no of the offered item along with offer 3- OEM should be ISO certified company
CKT BREAKER FOR ROLLER TABLES GRP DRIVE
CKT BREAKER FOR ROLLER TABLES GRP DRIVE Supply of 3 Pole Moulded Case Circuit Breaker-MCCB as per the specifications given below- Rated Capacity- 63 A Breaking Capacity Ics equal to 100 percent icu equal to 25 KA at 415 V AC Trip Unit- Thermo Magnetic with Short Circuit protection Adjustable Over Load protection NOTE- 1- Manufacturers Catalogue Number should be mentioned for each item in the Offer 2- The offered item technical specifications should be suitable to industry-comply with IPSS- 1-04-004-11 3- OEM should be ISO certified company
MCCBs THER RAT 100A WITH 56 percent PLUG SETTING
MCCBs THER RAT 100A WITH 56 percent PLUG SETTING Supply of 3 Pole Moulded Case Circuit Breakers-MCCB as per the specifications given below- Rated Capacity- 100A Breaking Capacity Ics equal to 100 percent icu equal to 25 KA at 415 V AC Trip Unit- Thermo Magnetic with Short Circuit protection Adjustable Over Load protection NOTE- 1- Manufacturers Catalogue Number should be mentioned for each item in the Offer 2- The offered item technical specifications should be suitable to industry-comply with IPSS- 1-04-004-11 3- OEM should be ISO certified company
CKT BREAKER FOR and HE BACKWASH PUMPS 160A
CKT BREAKER FOR and HE BACKWASH PUMPS 160A Supply of 3 Pole Moulded Case Circuit Breakers-MCCB as per the specifications given below- Rated Capacity- 160A Breaking Capacity Ics equal to 100 percent icu equal to 25 KA at 415 V AC Trip Unit- Thermo Magnetic with Short Circuit protection Adjustable Over Load protection NOTE- 1- Manufacturers Catalogue Number should be mentioned for each item in the Offer 2- The offered item technical specifications should be suitable to industry-comply with IPSS- 1-04-004-11 3- OEM should be ISO certified company
3-POLE MOULDED CASE CIRCUIT BREAKER 250A
3-POLE MOULDED CASE CIRCUIT BREAKER 250A Supply of 3 Pole Moulded Case Circuit Breakers-MCCB- as per the specifications given below- Rated Capacity- 250A Breaking Capacity Ics equal to 100 percent icu equal to 25 KA at 415 V AC Trip Unit- Thermo Magnetic with Short Circuit protection Adjustable Over Load protection NOTE- 1- Manufacturers Catalogue Number should be mentioned for each item in the Offer 2- The offered item technical specifications should be suitable to industry-comply with IPSS- 1-04-004-11 3- OEM should be ISO certified company
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | MPCB RATING 4-6 point 3 AMPS 50KA | MPCB RATING 4-6 point 3 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 4 to 6 point 3 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism-Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no of the offered item along with offer 3- OEM should be ISO certified company | 7 | nos | mm-stores | 60 | |
| 2 | MPCB RATING 6-10 AMPS 50KA | MPCB RATING 6-10 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 6 to 10 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism- Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no of the offered item along with offer 3- OEM should be ISO certified company | 7 | nos | mm-stores | 60 | |
| 3 | MPCB RATING 10-16 AMPS 50KA | MPCB RATING 10-16 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 10 to 16 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism- Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no of the offered item along with offer 3- OEM should be ISO certified company | 10 | nos | mm-stores | 60 | |
| 4 | MPCB RATING 16-20 AMPS | MPCB RATING 16-20 AMPS 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 16 to 20 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism- Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no. of the offered item along with offer 3- OEM should be ISO certified company | 20 | nos | mm-stores | 60 | |
| 5 | MPCB RATING 20-25 AMPS 50KA | MPCB RATING 20-25 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 20 to 25 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism- Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no. of the offered item along with offer 3- OEM should be ISO certified company | 18 | nos | mm-stores | 60 | |
| 6 | MPCB RATING 25-32 AMPS 50KA | MPCB RATING 25-32 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 25 to 32 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism- Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no of the offered item along with offer 3- OEM should be ISO certified company | 10 | nos | mm-stores | 60 | |
| 7 | MPCB RATING 28-40 AMPS 50KA | MPCB RATING 28-40 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Current range- 28 to 40 Amps Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics equal to 100 percent icu equal to 50 KA at 415 V AC Trip Mechanism- Thermal plus Magnetic NOTE- 1- MPCB with nearest current range may be offered if MPCB with above-said current range is unavailable 2- Shall furnish Make and Part no of the offered item along with offer 3- OEM should be ISO certified company | 5 | nos | mm-stores | 60 | |
| 8 | CKT BREAKER FOR ROLLER TABLES GRP DRIVE | CKT BREAKER FOR ROLLER TABLES GRP DRIVE Supply of 3 Pole Moulded Case Circuit Breaker-MCCB as per the specifications given below- Rated Capacity- 63 A Breaking Capacity Ics equal to 100 percent icu equal to 25 KA at 415 V AC Trip Unit- Thermo Magnetic with Short Circuit protection Adjustable Over Load protection NOTE- 1- Manufacturers Catalogue Number should be mentioned for each item in the Offer 2- The offered item technical specifications should be suitable to industry-comply with IPSS- 1-04-004-11 3- OEM should be ISO certified company | 7 | nos | mm-stores | 60 | |
| 9 | MCCBs THER RAT 100A WITH 56 percent PLUG SETTING | MCCBs THER RAT 100A WITH 56 percent PLUG SETTING Supply of 3 Pole Moulded Case Circuit Breakers-MCCB as per the specifications given below- Rated Capacity- 100A Breaking Capacity Ics equal to 100 percent icu equal to 25 KA at 415 V AC Trip Unit- Thermo Magnetic with Short Circuit protection Adjustable Over Load protection NOTE- 1- Manufacturers Catalogue Number should be mentioned for each item in the Offer 2- The offered item technical specifications should be suitable to industry-comply with IPSS- 1-04-004-11 3- OEM should be ISO certified company | 9 | nos | mm-stores | 60 | |
| 10 | CKT BREAKER FOR and HE BACKWASH PUMPS 160A | CKT BREAKER FOR and HE BACKWASH PUMPS 160A Supply of 3 Pole Moulded Case Circuit Breakers-MCCB as per the specifications given below- Rated Capacity- 160A Breaking Capacity Ics equal to 100 percent icu equal to 25 KA at 415 V AC Trip Unit- Thermo Magnetic with Short Circuit protection Adjustable Over Load protection NOTE- 1- Manufacturers Catalogue Number should be mentioned for each item in the Offer 2- The offered item technical specifications should be suitable to industry-comply with IPSS- 1-04-004-11 3- OEM should be ISO certified company | 6 | nos | mm-stores | 60 | |
| 11 | 3-POLE MOULDED CASE CIRCUIT BREAKER 250A | 3-POLE MOULDED CASE CIRCUIT BREAKER 250A Supply of 3 Pole Moulded Case Circuit Breakers-MCCB- as per the specifications given below- Rated Capacity- 250A Breaking Capacity Ics equal to 100 percent icu equal to 25 KA at 415 V AC Trip Unit- Thermo Magnetic with Short Circuit protection Adjustable Over Load protection NOTE- 1- Manufacturers Catalogue Number should be mentioned for each item in the Offer 2- The offered item technical specifications should be suitable to industry-comply with IPSS- 1-04-004-11 3- OEM should be ISO certified company | 6 | nos | mm-stores | 60 |
PAN Card copy
GSTIN copy
Cancelled cheque
EFT Mandate copy certified by bank
GST invoice copy and GST portal payment screenshot
Invoice to be raised in consignee name with GSTIN
Vendor code creation documents as per Terms
Technical bid documents and OEM authorizations as per uploaded ATC
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | AK. TECH. ELECTRICAL Under PMA | - | 06-12-2025 17:38:37 | |
| 2 | ANGEL INDUSTRIAL INSTRUMENTATION Under PMA | - | 08-12-2025 14:57:07 | |
| 3 | D J ASSOCIATES Under PMA | - | 04-12-2025 12:35:25 | |
| 4 | G K ENTERPRISES Under PMA | - | 08-12-2025 14:44:11 | |
| 5 | G S ENTERPRISES Under PMA | - | 08-12-2025 14:55:11 | |
| 6 | INDIA MOTOR STORES Under PMA | - | 02-12-2025 09:29:34 | |
| 7 | INDUSTRIAL ASSOCIATES Under PMA | - | 08-12-2025 08:20:46 | |
| 8 | JAI SHREE GANESH AUTOMATION Under PMA | - | 08-12-2025 14:42:31 | |
| 9 | LAXMI ELECTRICALS Under PMA | - | 06-12-2025 18:12:21 | |
| 10 | S.B. SYSCON PRIVATE LIMITED Under PMA | - | 29-11-2025 16:56:06 | |
| 11 | SHREE SHYAM TRADERS Under PMA | - | 30-11-2025 17:36:50 | |
| 12 | STAR ELECTRICAL ENTERPRISE Under PMA | - | 08-12-2025 14:51:46 | |
| 13 | VIVEK ENTERPRISES Under PMA | - | 07-12-2025 23:21:55 |
Please sign in or create an account to view contract details and download result documents.
Key insights about KARNATAKA tender market
To bid, ensure you meet GST and PAN prerequisites, submit PAN, GSTIN, cancelled cheque, and EFT mandate, and prepare GST-compliant invoice in consignee name. Review the ATC for exact quantities, delivery milestones, and ensure supply-only scope with 2-month delivery from PO.
Submit PAN, GSTIN, cancelled cheque, EFT mandate, GST invoice copy and GST portal payment proof, and vendor-code creation documents. Ensure invoice is raised in consignee name with GSTIN and attach technical bid documents per the uploaded ATC.
Refer to the uploaded ATC for precise itemized specs. Public data lists MPCB ratings from 4-6 AMPS to 28-40 AMPS with 50KA, 160A backwash-pump breakers, and 250A MCCB (3-pole). Exact quantities and standards are available in the ATC document.
Delivery must be completed within 2 months from the purchase order date, as specified in the ATC. Plan production and shipping to meet this tight timeline and align with PO milestones to avoid penalties.
GST is reimbursed based on actuals or applicable rates (whichever is lower), capped by the quoted GST percentage. Bidders must provide GST invoices and portal payment screenshots to confirm tax compliance.
Eligible bidders must have GST registration, PAN, and the ability to supply the listed electrical protection equipment. They must also complete vendor-code creation and provide EFT mandate and technical bid documents per ATC.
The BOQ comprises 11 items with protections including MPCB ratings (4-32 AMPS) at 50KA, roller-table breakers, 56% plug-setting MCCBs, 160A backwash-pump breakers, and 250A 3-pole MCCBs; exact quantities are provided in the uploaded ATC.
Sign up now to access all documents
Main Document
BOQ
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS