1.5 T MRI Machine
Hll Lifecare Limited
THIRUVANANTHAPURAM, KERALA
Progress
Quantity
11
Bid Type
Two Packet Bid
Organization: HLL Infra Tech Services Limited, under the Department of Health and Family Welfare, invites bids for a 3T MRI machine and comprehensive accessory suite. Estimated value: ₹2,337,500,000 with an EMD of ₹46,750,000. The scope covers magnets, gantry, shimming, patient table with transfer cart, multiple coils, RF system, gradient system, spectroscopy, post-processing workstation, server hardware, and extensive pre-installation civil/Electrical/AC works. Location details are not specified in the data, but the procurement targets government health infrastructure upgrades. A wide-coil configuration and patient comfort features (detachable faces, mirrors, and anxiety-reducing elements) are highlighted as differentiators. The tender emphasizes advanced imaging capabilities (isotropic 3-D T1/T2, Dixon, parallel imaging, perfusion, DTI, cardiac imaging, and multi-nuclear spectroscopy) to support multi-site clinical deployment and sophisticated research. The inclusion of pre-installation site works signals a turnkey delivery expectation, with a strong focus on installation, commissioning, and maintenance readiness. The award will hinge on compliance with technical breadth, delivery readiness, and warranty/after-sales commitments.
Keywords: tender in India, HLL procurement, 3T MRI machine, MRI system turnkey delivery, ISI/ISO compliant, defence-like reliability, post-processing workstation, pre-installation civil works.
3T MRI system, ISI/ISO compliant, with Head/Neck, Spine, Breast coils
MR-compatible accessories: injector, ventilator, ECG/SpO2 monitor, anesthesia and O2 pipeline
Post-processing workstation with DTI, MIP/MPR, cardiac imaging and spectroscopy modules
Server hardware: minimum RAM and storage as per data sheet; monitor type specified
Pre-installation works: 900 sq ft area; RF shielding for doors and walls
EMD of ₹46,750,000 required with bid; MSME/NSIC exemptions if eligible
Delivery clause allows ±50% quantity variation; minimum 30 days extra time
Warranty 2 years with OEM certificates; option for comprehensive warranty
Pre-installation site works included; seller to arrange civil/electrical/plumbing/AC
GST compliance: invoice to consignee with GSTIN; GST portal payment confirmation
GST as applicable; invoice in consignee name with GSTIN; upload GST invoice and GST payment confirmation on GeM
Option to increase/decrease quantity up to 50% with proportional delivery time adjustments; minimum 30 days extension when applicable
LD for delays as per bid terms; ensure timely installation/commissioning and service support during warranty
Experience in supplying and installing MRI systems (3T) with full coil arrays
Demonstrated post-sales service network across India
Financial capability evidenced by last 3 years’ statements and GST compliance
Hll Lifecare Limited
THIRUVANANTHAPURAM, KERALA
Hll Lifecare Limited
THIRUVANANTHAPURAM, KERALA
Ntpc Limited
KORBA, CHHATTISGARH
Hospital Medical Education
AIZAWL, MIZORAM
N/a
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| MAGNET | Magnet Configuration | Normal bore, Wide Bore |
| GANTRY | Bore diameter at isocenter (cm) | 60, 70 |
| GANTRY | Maximum bore length with cover (cm) | 140-149, 150-159, 160-169, 170-179, 180-189, 190 and above |
| SHIM SYSTEM | Type of shimming | Active, Passive, Active and Passive, Passive, linear and higher order active |
| PATIENT TABLE | Safe patient transfer cart provided | Yes, No |
| PATIENT TABLE | Table Type | Dockable, Fixed |
| PATIENT TABLE | Table movements | Vertical, Horizontal, Vertical and Horizontal |
| PATIENT TABLE | Lateral movement in Table | Yes, No |
| GRADIENT SYSTEM | Peak Amplitude with each axis independently mT/m | ≥ 30, ≥ 40, ≥ 60, ≥ 80 |
| GRADIENT SYSTEM | Standard slew rate, with each axis independently T/m/sec | ≥ 100, ≥ 200 |
| RF SYSTEM | Minimum RF transmitter and receiver power output (KW) | 20, 30, 40 |
| RF SYSTEM | Number of minimum independent / quadrature RF receiver channels that can be used simultaneously in one single scan and in one single FOV | 8, 16, 24, 32, 48, 64, 128, Digital imaging with direct digital interface and digital surround technology, ADC at the coil (channel independent) |
| RF SYSTEM | RF system's minimum number of elements that can be connected simultaneously in single FOV and single scan | 16, 24, 32, 48, 128, 204, Coil and FOV Dependent |
| COIL SYSTEM | Parallel imaging -uses redundant information acquired by multiple coil elements to significantly accelerate image acquisition The overall image time can be reduced by a factor of two or more | Yes, No |
| COIL SYSTEM | Head and Neck Coil - Number of elements (minimum) | 8, 10, 14, 16, 20, 32, 37, 48, 64 Or higher |
| COIL SYSTEM | Head and Neck coil, Detachable face - a detachable front section is Intended to help reduce patient anxiety | Yes, No |
| COIL SYSTEM | Head and Neck Coil, Patient mirror(s) - include a small mirror that enables the patient to see outside the bore, which can reduce patient anxiety | Yes, No |
| COIL SYSTEM | Spine Coil - Number of elements (minimum) | 12, 16, 18, 24, 32, 44, 60, 40 Or higher |
| COIL SYSTEM | Dedicated Anterior body Coil with Spine Coil (body imaging at Max FOV) 45cm (single or combination of coils) - Maximum elements used simultaneously | 9, 18, 29, 32, 36, 60, 12, 24, 6 Or higher |
| COIL SYSTEM | Breast Coil | Yes, No |
| COIL SYSTEM | Breast Coil - Number of elements (minimum) | 4, 7, 8, 16, 18, NA |
| COIL SYSTEM | Dedicated Breast Biopsy coil | Yes, No |
| COIL SYSTEM | Spine (CTL) | Yes, No |
| COIL SYSTEM | Head + Neck, Neuro-Vasculature | Yes, No |
| COIL SYSTEM | Whole CNS (Head + Whole Spine) | Yes, No |
| COIL SYSTEM | Chest, Heart | Yes, No |
| COIL SYSTEM | Abdomen, Pelvis | Yes, No |
| COIL SYSTEM | Whole Abdomen | Yes, No |
| COIL SYSTEM | Peripheral Vasculature | Yes, No |
| COIL SYSTEM | Prostate, Colon, Rectum, Cervix | Yes, No |
| COIL SYSTEM | Dedicated Knee Coil | Yes, No |
| COIL SYSTEM | Knee coil - number of elements | ≥ 8, ≥ 15, NA |
| COIL SYSTEM | Dedicated Ankle coil | Yes, No |
| COIL SYSTEM | Ankle coil - number of elements | ≥ 8, ≥ 16, NA |
| COIL SYSTEM | Dedicated Shoulder coils | Yes, No |
| COIL SYSTEM | Shoulder coil - number of elements | ≥ 3, ≥ 8, ≥ 15, NA |
| COIL SYSTEM | Wrist coil - number of elements | ≥ 8, ≥ 16, NA |
| COIL SYSTEM | Multi-Purpose Coils | Yes, No |
| COIL SYSTEM | Temporo-Mandibular Joints | Yes, No |
| COIL SYSTEM | Whole Body | Yes, No |
| COIL SYSTEM | Flex coils small and large at least 4 channel | Yes, No |
| COIL SYSTEM | Multi nuclear spectroscopy with one multinuclear coil | Yes, No |
| SCANNING TECHNIQUES | Standard pulse sequences (Series of RF and gradient pulses used to generate MR signals for image acquisition) | Yes, No |
| SCANNING TECHNIQUES | Image acquisition - Patient movement compensated, head and body | Yes, No |
| SCANNING TECHNIQUES | Isotropic 3-D (T1) and Isotropic 3-D fast spin echo (T2) | Yes, No |
| SCANNING TECHNIQUES | Fat supressed Single breath-hold 3-D body imaging using parallel acquisition of gradient echo pulse sequences | Yes, No |
| SCANNING TECHNIQUES | Single-point Dixon acquisition - this technique generates different image contrasts such as water-only, fat-only, in-phase, and out-of-phase | Yes, No |
| SCANNING TECHNIQUES | Gradient Echo - An imaging sequence in which echo is created by switching a pair of dephasing and rephasing gradients such as spoiled, rewound and Steady state free precession techniques | Yes, No |
| SCANNING TECHNIQUES | Spectroscopy for Breast | Yes, No |
| SCANNING TECHNIQUES | Spectroscopy for Prostate | Yes, No |
| SCANNING TECHNIQUES | multi parametric study for prostate | Yes, No |
| SCANNING TECHNIQUES | Bilateral Breast imaging with fat suppression with time intensity graph | Yes, No |
| SCANNING TECHNIQUES | Non-contrast angiographic imaging technique (time of flight, phase contrast and SSFP) is used to visualize flow within vessels | Yes, No |
| WORKSTATION QUANTITATIVE IMAGE ANALYSIS TOOLS | Neuro Perfusion imaging tools | Yes, No |
| WORKSTATION QUANTITATIVE IMAGE ANALYSIS TOOLS | fMRI tools | Yes, No |
| WORKSTATION QUANTITATIVE IMAGE ANALYSIS TOOLS | Diffusion Imaging tools | Yes, No |
| WORKSTATION QUANTITATIVE IMAGE ANALYSIS TOOLS | Diffusion tensor imaging tools | Yes, No |
| WORKSTATION QUANTITATIVE IMAGE ANALYSIS TOOLS | Cardiac imaging tools | Yes, No |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | Image post processing workstation model | Standalone, Client server |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | If it is server workstation, number of nodes to be provided | 1, 2, 3, 4, Not Applicable in case of Standalone Workstation |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | l necessary compatible and up gradable software including post processing software for all offered application including DTI and other associated post processing like MIP, MPR, and surface reconstruction to be provided | Yes, No |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | Software's for analyzing DWI, Spectroscopy, perfusion, CSF flow data, T1 relaxation, T2 relaxation, T2*relaxation to be provided | Yes, No |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | System should be capable of having number of DTI directions (minimum) | 12, 32, 128, 256 Or higher |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | Cardiac package for morphology and cardiac angiography | Yes, No |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | Output in the form of jpeg, avi /equivalent formats | Yes, No |
| WORKSTATION SPECIFICATIONS AND APPLICATIONS | Display of cardiac cine images in movie mode with rapid avi creation in workstation | Yes, No |
| SERVER HARDWARE | Image storage capacity of Server | ≥ 2 TB, Not Applicable in case of Standalone Workstation |
| SERVER HARDWARE | Minimum Processing Power of Server | 20,000 concurrent slices, Not Applicable in case of Standalone Workstation, 16,000 concurrent slices |
| SERVER HARDWARE | Ram Size of server | ≥ 32 GB, Not Applicable in case of Standalone Workstation |
| SERVER HARDWARE | Size of Monitor of Server | 19 inch or more, Not Applicable in case of Standalone Workstation |
| SERVER HARDWARE | Type of Monitor of Server | LCD/LED/TFT, Not Applicable in case of Standalone Workstation |
| WORKSTATION HARDWARE | Minimum Ram Size of Workstation | 4, 8, 16 Or higher |
| WORKSTATION HARDWARE | Minimum Storage capacity of Workstation | 500, 1000 Or higher |
| ACCESSORIES | MRI Compatible auto pressure injector | Yes, No |
| ACCESSORIES | MR Compatible basic ventillator | Yes, No |
| ACCESSORIES | MR Compatible Monitor (ECG, SpO2, NIBP, RR and HR/PR) with slave display in control room | Yes, No |
| ACCESSORIES | MR Compatible medical O2 gas pipeline with cylinder and standard accessories | Yes, No |
| ACCESSORIES | MRI Compatible trolley and wheel chair to transfer patient in and out of gantry room | Yes, No |
| ACCESSORIES | Dry laser camera with minimum resolution of 500 DPI and with three trays to accommodate three different size of films | Yes, No |
| ACCESSORIES | Online UPS for entire system for backup of at least 30 minutes | Yes, No |
| PRE-INSTALLATION SITE REQUIREMENTS | Preparation of MRI Room , console Room , Technical room, patient preparation room, one wash room etc to be done by the seller in the area of approx 900 Sq feet | Yes, No |
| PRE-INSTALLATION SITE REQUIREMENTS | Vinyl flooring, wooden panels and good quality false ceiling in MRI room to be done by the seller | Yes, No |
| PRE-INSTALLATION SITE REQUIREMENTS | Tile based false ceiling and floor tiling and wall tiling till false ceiling in rooms other than MRI room to be done by the seller | Yes, No |
| PRE-INSTALLATION SITE REQUIREMENTS | Necessary modification civil work, electrical , plumbing, furnishing, air conditioning in the given area to be done by the seller | Yes, No |
| PRE-INSTALLATION SITE REQUIREMENTS | Doors other than main MRI room to be of good quality Aluminium doors and to be done by the seller | Yes, No |
| PRE-INSTALLATION SITE REQUIREMENTS | RF shielding for doors, wall, glass viewer etc to be done by the seller | Yes, No |
| WARRANTY | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5, 2, 3 Or higher |
Discover companies most likely to bid on this tender
GST registration certificate
PAN card
Experience certificates of similar MRI system supply and installation
Financial statements for last 3 years
EMD payment receipt or exemption certificate
OEM authorization/cManufacturer authorizations
Technical bid documents including product data sheets
Make in India authorization certificate (if applicable)
Service center details and post-sales support plan
Extended Deadline
13-Jan-2026, 3:00 pm
Opening Date
13-Jan-2026, 3:30 pm
Extended Deadline
30-Dec-2025, 3:00 pm
Opening Date
30-Dec-2025, 3:30 pm
Extended Deadline
16-Dec-2025, 3:00 pm
Opening Date
16-Dec-2025, 3:30 pm
Extended Deadline
02-Dec-2025, 3:00 pm
Opening Date
02-Dec-2025, 3:30 pm
Key insights about ASSAM tender market
Bidders must meet eligibility, submit GST, PAN, experience certs, financials, EMD ₹46.75M, OEM authorization, and data sheets. Include Make in India cert if applicable, and provide service network details. Ensure compliance with ISI/ISO standards and attach warranty certificates during delivery.
Required documents include GST certificate, PAN, experience certificates for MRI projects, last 3 years financial statements, EMD proof, OEM authorizations, technical data sheets, proof of service centers, and pre-installation plans for room works and shielding.
System must include 3T magnet, gantry with specified bore, shimming, full coil array (Head/Neck, Spine, Breast, Knee, Shoulder, Whole-Body), isotropic 3-D T1/T2, Dixon and spectroscopy capabilities, parallel imaging, MR-compatible accessories, and a compatible workstation with post-processing tools.
EMD is ₹46,750,000. Payment terms require GST-compliant invoicing in the consignee name with GSTIN; invoicing and GST payment confirmations must be uploaded on the GeM portal; comprehensive warranty may impact payment milestones.
Turnkey delivery includes room preparation (~900 sq ft), RF shielding, civil/electrical/plumbing/AC works by the seller, aluminium doors, and validated commissioning. The option clause allows ±50% quantity change with proportional delivery time adjustments.
A two-year standard OEM warranty is required; bidders must provide OEM warranty certificates and establish service centers nationwide with timely response; comprehensive warranty may be opted, superseding standard terms.
Seller must execute MRI room, console room, technical room, patient prep room, and washroom setups; flooring, false ceilings, tiling, and wall work; and RF shielding. All civil/electrical/plumbing/AC adaptations are seller responsibilities.
If quantity changes by up to 50%, delivery time scales proportionally using (additional quantity/original quantity) × original delivery period, with a minimum extension of 30 days; extended timing applies during contract currency.