Bid Publish Date
03-Feb-2026, 10:11 am
Bid End Date
13-Feb-2026, 11:00 am
Location
Progress
Quantity
2621
Category
100000000000 Supply of high static pressure Ductable AC unit capacity not less than 16.5 TR having one indoor and refer annexure III
Bid Type
Two Packet Bid
Bharat Electronics Limited (bel) has released a public tender for 100000000000 Supply of high static pressure Ductable AC unit capacity not less than 16. 5 TR having in GHAZIABAD, UTTAR PRADESH. Quantity: 2621. Submission Deadline: 13-02-2026 11: 00: 00. Download documents and apply online.
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | 100000000000 Supply of high static pressure Ductable AC unit capacity not less than 16.5 TR having one indoor and refer annexure III | Supply of high static pressure Ductable AC unit capacity not less than 16.5 TR having one indoor and refer annexure III | 3 | nos | con5.bel.gzb | 45 |
| 2 | 100000000001 Supply of High Wall Mount type Hot and Cold Split AC Units of cooling capacity not less than 2.0 TR minimum 3 star rating Inverter type rotary refer annexure III | Supply of High Wall Mount type Hot and Cold Split AC Units of cooling capacity not less than 2.0 TR minimum 3 star rating Inverter type rotary refer annexure III | 4 | nos | con5.bel.gzb | 45 |
| 3 | 100000000002 Supply of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split AC units of capacity 16.5 TR for suction refer annexure III | Supply of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split AC units of capacity 16.5 TR for suction refer annexure III | 60 | rmt | con5.bel.gzb | 45 |
| 4 | 100000000003Supply of suitable size refrigerant grade copper piping between indoor and outdoor units of split AC Hotand Cold units capacity 2 TR refer annexure III | Supply of suitable size refrigerant grade copper piping between indoor and outdoor units of split AC Hotand Cold units capacity 2 TR refer annexure III | 50 | rmt | con5.bel.gzb | 45 |
| 5 | 100000000004 Supply of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes refer annexure III | Supply of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes refer annexure III | 50 | rmt | con5.bel.gzb | 45 |
| 6 | 100000000005 Supply of cPVC SDR11 pipe of 25 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure III | Supply of cPVC SDR11 pipe of 25 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure III | 50 | rmt | con5.bel.gzb | 45 |
| 7 | 100000000006 Supply of cPVC SDR11 pipe of 32 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure III | Supply of cPVC SDR11 pipe of 32 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure III | 50 | rmt | con5.bel.gzb | 45 |
| 8 | 100000000007 Supply of site fabricated GI sheet metal ducts of 24 Guage Birmingham Gauge 0.63 mm and zinc coating refer annexure III | Supply of site fabricated GI sheet metal ducts of 24 Guage Birmingham Gauge 0.63 mm and zinc coating refer annexure III | 250 | sqm | con5.bel.gzb | 45 |
| 9 | 1000000000008 Supply of site fabricated GI sheet metal ducts of 22 Guage Birmingham Gauge 0.80 mm and zinc coating refer annexure III | Supply of site fabricated GI sheet metal ducts of 22 Guage Birmingham Gauge 0.80 mm and zinc coating refer annexure III | 30 | sqm | con5.bel.gzb | 45 |
| 10 | 100000000009 Supply of thermal insulation for supply air ducts with 19 mm thick self-adhesive closed cell elastomeric refer annexure III | Supply of thermal insulation for supply air ducts with 19 mm thick self-adhesive closed cell elastomeric refer annexure III | 300 | sqm | con5.bel.gzb | 45 |
| 11 | 100000000010 Supply of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam insulation refer annexure III | Supply of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam insulation refer annexure III | 30 | sqm | con5.bel.gzb | 45 |
| 12 | 100000000011 Supply of volume control dampers for ducts made of GI sheet of thickness not less than 18 G including fittings refer annexure III | Supply of volume control dampers for ducts made of GI sheet of thickness not less than 18 G including fittings refer annexure III | 3 | sqm | con5.bel.gzb | 45 |
| 13 | 100000000012 Supply of supply air diffusersorgrill with powder coated aluminium refer annexure III | Supply of supply air diffusersorgrill with powder coated aluminium refer annexure III | 12 | sqm | con5.bel.gzb | 45 |
| 14 | 100000000013 Supply of return air diffusersorgrill with powder coated aluminium single piece refer annexure III | Supply of return air diffusersorgrill with powder coated aluminium single piece refer annexure III | 12 | sqm | con5.bel.gzb | 45 |
| 15 | 100000000014 Supply of 27 KW finned type electric strip air heaters for winter heating in three banks 9 KW in each bank refer annexure III | Supply of 27 KW finned type electric strip air heaters for winter heating in three banks 9 KW in each bank refer annexure III | 1 | set | con5.bel.gzb | 45 |
| 16 | 100000000015 Supply of fire dampers in supply air duct of required size controlwiring,the damper shall be motorised and spring return refer annexure III | Supply of fire dampers in supply air duct of required size controlwiring,the damper shall be motorised and spring return refer annexure III | 2 | sqm | con5.bel.gzb | 45 |
| 17 | 100000000016 Supply of control instruments and sensors required for Combined fire and smoke damper including actuators refer annexure III | Supply of control instruments and sensors required for Combined fire and smoke damper including actuators refer annexure III | 1 | each | con5.bel.gzb | 45 |
| 18 | 100000000017 Supply of freshor exhaust air louvers made of extruded aluminium with birdor insect screen including volume control damper made of aluminium refer annexure III | Supply of freshor exhaust air louvers made of extruded aluminium with birdor insect screen including volume control damper made of aluminium refer annexure III | 1 | sqm | con5.bel.gzb | 45 |
| 19 | 100000000018 Supply of Floor mounted cubicle non drawout electrical control panel for operating 3 nos Ductable unit and 1 no heater bank total 4 nos outgoing feeder refer annexure III | Supply of Floor mounted cubicle non drawout electrical control panel for operating 3 nos Ductable unit and 1 no heater bank total 4 nos outgoing feeder refer annexure III | 1 | nos | con5.bel.gzb | 45 |
| 20 | 100000000019 Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed armoured extruded PVC outer sheathed refer annexure III | Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed armoured extruded PVC outer sheathed refer annexure III | 200 | rmt | con5.bel.gzb | 45 |
| 21 | 100000000020 Supply of XLPE insulated PVC sheathed armoured copper conductor 2XFY, 1.1 kV grade LT cable of size 4.0 core - 2.5 sqmm refer annexure III | Supply of XLPE insulated PVC sheathed armoured copper conductor 2XFY, 1.1 kV grade LT cable of size 4.0 core - 2.5 sqmm refer annexure III | 100 | rmt | con5.bel.gzb | 45 |
| 22 | 100000000021 Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1.6 mm thickness refer annexure III | Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1.6 mm thickness refer annexure III | 100 | rmt | con5.bel.gzb | 45 |
| 23 | 100000000022 Installation testing and commissioning of high static pressure Ductable AC unit capacity not less than 16.5 TR having one indoor and refer annexure IV | Installation testing and commissioning of high static pressure Ductable AC unit capacity not less than 16.5 TR having one indoor and refer annexure IV | 3 | nos | con5.bel.gzb | 45 |
| 24 | 100000000023 Erection testing and commissioning of High Wall Mount type Hot and Cold Split AC Units of cooling capacity not less than 2.0 TR minimum 3 star rating Inverter refer annexure IV | Erection testing and commissioning of High Wall Mount type Hot and Cold Split AC Units of cooling capacity not less than 2.0 TR minimum 3 star rating Inverter refer annexure IV | 4 | nos | con5.bel.gzb | 45 |
| 25 | 100000000024 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split AC refer annexure IV | erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split AC refer annexure IV | 60 | rmt | con5.bel.gzb | 45 |
| 26 | 100000000025 Erection, testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of split AC refer annexure IV | Erection, testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of split AC refer annexure IV | 50 | rmt | con5.bel.gzb | 45 |
| 27 | 100000000026 Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling refer annexure IV | Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling refer annexure IV | 50 | rmt | con5.bel.gzb | 45 |
| 28 | 100000000027 Laying of cPVC SDR11 pipe of 25 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure IV | Laying of cPVC SDR11 pipe of 25 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure IV | 50 | rmt | con5.bel.gzb | 45 |
| 29 | 100000000028 Laying of cPVC SDR11 pipe of 32 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure IV | Laying of cPVC SDR11 pipe of 32 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure IV | 50 | rmt | con5.bel.gzb | 45 |
| 30 | 100000000029 Fabrication installation testing and commissioning of site fabricated GI sheet metal ducts of 24 Guage Birmingham Gauge refer annexure IV | Fabrication installation testing and commissioning of site fabricated GI sheet metal ducts of 24 Guage Birmingham Gauge refer annexure IV | 250 | sqm | con5.bel.gzb | 45 |
| 31 | 100000000030 Fabrication, installation, testing and commissioning of site fabricated GI sheet metal ducts of 22 Guage Birmingham Gauge refer annexure IV | Fabrication, installation, testing and commissioning of site fabricated GI sheet metal ducts of 22 Guage Birmingham Gauge refer annexure IV | 30 | sqm | con5.bel.gzb | 45 |
| 32 | 100000000031 fixing of thermal insulation for supply air ducts with 19 mm thick self-adhesive closed cell elastomeric nitrile rubber Class O refer annexure IV | fixing of thermal insulation for supply air ducts with 19 mm thick self-adhesive closed cell elastomeric nitrile rubber Class O refer annexure IV | 300 | sqm | con5.bel.gzb | 45 |
| 33 | 100000000032 Fixing of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam insulation refer annexure IV | Fixing of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam insulation refer annexure IV | 30 | sqm | con5.bel.gzb | 45 |
| 34 | 100000000033 Erection testing and commissioning of volume control dampers for ducts made of GI sheet of thickness not less than 18 G including fittings refer annexure IV | Erection testing and commissioning of volume control dampers for ducts made of GI sheet of thickness not less than 18 G including fittings refer annexure IV | 3 | sqm | con5.bel.gzb | 45 |
| 35 | 100000000034 fixing, testing and commissioning of supply air diffusersorgrill with powder coated aluminium single piece moulded frame refer annexure IV | fixing, testing and commissioning of supply air diffusersorgrill with powder coated aluminium single piece moulded frame refer annexure IV | 12 | sqm | con5.bel.gzb | 45 |
| 36 | 100000000035 Fxing, testing and commissioning of return air diffusersorgrill with powder coated aluminium single piece moulded frame refer annexure IV | Fxing, testing and commissioning of return air diffusersorgrill with powder coated aluminium single piece moulded frame refer annexure IV | 12 | sqm | con5.bel.gzb | 45 |
| 37 | 100000000036 Erection testing and commissioning of 27 KW finned type electric strip air heaters for winter heating in three banks 9 KW in each bank refer annexure IV | Erection testing and commissioning of 27 KW finned type electric strip air heaters for winter heating in three banks 9 KW in each bank refer annexure IV | 1 | set | con5.bel.gzb | 45 |
| 38 | 100000000037 Fxing testing and commissioning of fire dampers in supply air duct of required size controlwiring,the damper shall be motorised and refer annexure IV | Fxing testing and commissioning of fire dampers in supply air duct of required size controlwiring,the damper shall be motorised and refer annexure IV | 2 | sqm | con5.bel.gzb | 45 |
| 39 | 100000000038 Installation, testing and commissioning of control instruments and sensors required for Combined fire and smoke damper including actuator refer annexure IV | Installation, testing and commissioning of control instruments and sensors required for Combined fire and smoke damper including actuator refer annexure IV | 1 | each | con5.bel.gzb | 45 |
| 40 | 100000000039 Erection testing and commissioning of freshor exhaust air louvers made of extruded aluminium with birdor insect screen including volume control damper refer annexure IV | Erection testing and commissioning of freshor exhaust air louvers made of extruded aluminium with birdor insect screen including volume control damper refer annexure IV | 1 | sqm | con5.bel.gzb | 45 |
| 41 | 100000000040 Erection testing and commissioning of Floor mounted cubicle non drawout electrical control panel for operating 3 nos Ductable unit and 1 no heater refer annexure IV | Erection testing and commissioning of Floor mounted cubicle non drawout electrical control panel for operating 3 nos Ductable unit and 1 no heater refer annexure IV | 1 | nos | con5.bel.gzb | 45 |
| 42 | 100000000041 Laying of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed refer annexure IV | Laying of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed refer annexure IV | 200 | rmt | con5.bel.gzb | 45 |
| 43 | 100000000042 Laying of XLPE insulated PVC sheathed armoured copper conductor 2XFY 1.1 kV grade LT cable of size 4.0 core - 2.5 sq.mm refer annexure IV | Laying of XLPE insulated PVC sheathed armoured copper conductor 2XFY 1.1 kV grade LT cable of size 4.0 core - 2.5 sq.mm refer annexure IV | 100 | rmt | con5.bel.gzb | 45 |
| 44 | 100000000043 Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1.6 mm thickness refer annexure IV | Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1.6 mm thickness refer annexure IV | 100 | rmt | con5.bel.gzb | 45 |
| 45 | 100000000044 Dismantling and shifting of existing water cooled pakage 4 nos unit complete along with Pump including ducting refer annexure IV | Dismantling and shifting of existing water cooled pakage 4 nos unit complete along with Pump including ducting refer annexure IV | 1 | lot | con5.bel.gzb | 45 |
Discover companies most likely to bid on this tender
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS