11KV Indoor Resin Cast type CT,TTB Test Terminal Block for TOD meter,4 SQR MM Flexible Cu wire for
Indian Army
ERNAKULAM, KERALA
Bid Publish Date
14-Jan-2026, 12:03 pm
Bid End Date
26-Jan-2026, 3:00 pm
Location
Progress
Quantity
108
Category
E4953136 11KV Slot CT Wound CT 01-SG4950169050-11 KV SLOT CT RATIO- 630_slash_1-1A CORE-I-10VA 5P20 CORE-II- 10VA 0.5 AS PER ANN-A IT-01.
Bid Type
Two Packet Bid
Bharat Heavy Electricals Limited (bhel) invites bids for E4953136 11KV Slot CT Wound CT 01-SG4950169050-11 KV SLOT CT RATIO- 630_slash_1-1A CORE-I-10VA 5P20 CORE-II- 10VA 0. 5 AS PER ANN-A IT-01. , 02-SG4950169068-11 KV WOUND CT RATIO-630_slash_1A CORE-I- CL-PS VK_greatereq_14RCT_plus_15V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-02. , 03-SG4950169076-11 KV SLOT CT RATIO- 630-300_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0. 5 AS PER ANN-A IT-03. , 04-SG4950169084- 11 KV SLOT CT RATIO- 630-300_slash_1A CORE-I-CL-PS VK_greatereq_14RCT_plus_15V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-04. , 05-SG4950169092-11 KV WOUND CT RATIO- 300_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0. 5 AS PER ANN-A IT-05. , 06-SG4950169106- 11 KV WOUND CT RATIO- 300_slash_1A CORE-I-CL-PS VK_greatereq_15RCT_plus_46V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-06. , 07-SG4950169114-11 KV WOUND CT RATIO-250_slash_1-1A CORE-I-10VA 5P20 CORE- II-10VA 0. 2 AS PER ANN-A IT-07. , 08-SG4950169122-11 KV WOUND CT RATIO-200_slash_1-1A CORE-I-10VA 5P20 CORE- II-10VA 0. 2 AS PER ANN-A IT-08. , 09-SG4950169130-11 KV WOUND CT RATIO-200-250_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0. 2 AS PER ANN-A IT-09. , 10-SG4950169149- 11 KV WOUND CT RATIO-150_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0. 5 AS PER ANN-A IT-10. , 11-SG4950169157- 11 KV WOUND CT RATIO-150_slash_1A CORE-I-CL-PS VK_greatereq_13RCT_plus_12V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-11. , 12-SG4950169165-11 KV WOUND CT RATIO-150_slash_1A CORE-I-CL-PS VK_greatereq_13RCT_plus_18V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-12. , 13-SG4950169173-11 KV WOUND CT RATIO-60_slash_1-1A CORE-I-10VA 5P20 CORE- II-10VA 0. 5 AS PER ANN-A IT-13. , 14-SG4950169181-11 KV WOUND CT RATIO-50_slash_1-1A CORE-I-10VA 5P20 CORE- II-10VA 0. 5 AS PER ANN-A IT-14. in BHOPAL, MADHYA PRADESH. Quantity: 108. Submission Deadline: 26-01-2026 15: 00: 00. Submit your proposal before the deadline.
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Army
ERNAKULAM, KERALA
Bharat Heavy Electricals Limited (bhel)
BHOPAL, MADHYA PRADESH
Bharat Heavy Electricals Limited (bhel)
BHOPAL, MADHYA PRADESH
Bharat Heavy Electricals Limited (bhel)
BHOPAL, MADHYA PRADESH
Bharat Heavy Electricals Limited (bhel)
BHOPAL, MADHYA PRADESH
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | E4953136 11KV Slot CT Wound CT 01-SG4950169050-11 KV SLOT CT RATIO- 630_slash_1-1A CORE-I-10VA 5P20 CORE-II- 10VA 0.5 AS PER ANN-A IT-01. | E4953136 11KV Slot CT Wound CT 01-SG4950169050-11 KV SLOT CT RATIO- 630_slash_1-1A CORE-I-10VA 5P20 CORE-II- 10VA 0.5 AS PER ANN-A IT-01. | 6 | numbers | 209_swm_04 | 100 |
| 2 | 02-SG4950169068-11 KV WOUND CT RATIO-630_slash_1A CORE-I- CL-PS VK_greatereq_14RCT_plus_15V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-02. | 02-SG4950169068-11 KV WOUND CT RATIO-630_slash_1A CORE-I- CL-PS VK_greatereq_14RCT_plus_15V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-02. | 6 | numbers | 209_swm_04 | 100 |
| 3 | 03-SG4950169076-11 KV SLOT CT RATIO- 630-300_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.5 AS PER ANN-A IT-03. | 03-SG4950169076-11 KV SLOT CT RATIO- 630-300_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.5 AS PER ANN-A IT-03. | 3 | numbers | 209_swm_04 | 100 |
| 4 | 04-SG4950169084-11 KV SLOT CT RATIO- 630-300_slash_1A CORE-I-CL-PS VK_greatereq_14RCT_plus_15V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-04. | 04-SG4950169084-11 KV SLOT CT RATIO- 630-300_slash_1A CORE-I-CL-PS VK_greatereq_14RCT_plus_15V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-04. | 3 | numbers | 209_swm_04 | 100 |
| 5 | 05-SG4950169092-11 KV WOUND CT RATIO- 300_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.5 AS PER ANN-A IT-05. | 05-SG4950169092-11 KV WOUND CT RATIO- 300_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.5 AS PER ANN-A IT-05. | 12 | numbers | 209_swm_04 | 100 |
| 6 | 06-SG4950169106-11 KV WOUND CT RATIO- 300_slash_1A CORE-I-CL-PS VK_greatereq_15RCT_plus_46V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-06. | 06-SG4950169106-11 KV WOUND CT RATIO- 300_slash_1A CORE-I-CL-PS VK_greatereq_15RCT_plus_46V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-06. | 6 | numbers | 209_swm_04 | 100 |
| 7 | 07-SG4950169114-11 KV WOUND CT RATIO-250_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.2 AS PER ANN-A IT-07. | 07-SG4950169114-11 KV WOUND CT RATIO-250_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.2 AS PER ANN-A IT-07. | 6 | numbers | 209_swm_04 | 100 |
| 8 | 08-SG4950169122-11 KV WOUND CT RATIO-200_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.2 AS PER ANN-A IT-08. | 08-SG4950169122-11 KV WOUND CT RATIO-200_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.2 AS PER ANN-A IT-08. | 6 | numbers | 209_swm_04 | 100 |
| 9 | 09-SG4950169130-11 KV WOUND CT RATIO-200-250_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.2 AS PER ANN-A IT-09. | 09-SG4950169130-11 KV WOUND CT RATIO-200-250_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.2 AS PER ANN-A IT-09. | 3 | numbers | 209_swm_04 | 100 |
| 10 | 10-SG4950169149-11 KV WOUND CT RATIO-150_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.5 AS PER ANN-A IT-10. | 10-SG4950169149-11 KV WOUND CT RATIO-150_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.5 AS PER ANN-A IT-10. | 9 | numbers | 209_swm_04 | 100 |
| 11 | 11-SG4950169157-11 KV WOUND CT RATIO-150_slash_1A CORE-I-CL-PS VK_greatereq_13RCT_plus_12V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-11. | 11-SG4950169157-11 KV WOUND CT RATIO-150_slash_1A CORE-I-CL-PS VK_greatereq_13RCT_plus_12V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-11. | 6 | numbers | 209_swm_04 | 100 |
| 12 | 12-SG4950169165-11 KV WOUND CT RATIO-150_slash_1A CORE-I-CL-PS VK_greatereq_13RCT_plus_18V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-12. | 12-SG4950169165-11 KV WOUND CT RATIO-150_slash_1A CORE-I-CL-PS VK_greatereq_13RCT_plus_18V IM_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-12. | 3 | numbers | 209_swm_04 | 100 |
| 13 | 13-SG4950169173-11 KV WOUND CT RATIO-60_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.5 AS PER ANN-A IT-13. | 13-SG4950169173-11 KV WOUND CT RATIO-60_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.5 AS PER ANN-A IT-13. | 18 | numbers | 209_swm_04 | 100 |
| 14 | 14-SG4950169181-11 KV WOUND CT RATIO-50_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.5 AS PER ANN-A IT-14. | 14-SG4950169181-11 KV WOUND CT RATIO-50_slash_1-1A CORE-I-10VA 5P20 CORE-II-10VA 0.5 AS PER ANN-A IT-14. | 21 | numbers | 209_swm_04 | 100 |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Nlc Tamil Nadu Power Limited
📍 TUTICORIN, TAMIL NADU
Bharat Heavy Electricals Limited (bhel)
📍 BHOPAL, MADHYA PRADESH
Bharat Heavy Electricals Limited (bhel)
📍 BHOPAL, MADHYA PRADESH
Bharat Heavy Electricals Limited (bhel)
📍 BHOPAL, MADHYA PRADESH
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS