Public procurement opportunity for E-municipalities - Eservices To Citizens And Employees Of Urban Local Bodies Of Uttar Pradesh Power Generator - DG Set (up to 900 KVA) (Q2) in BIJNOR, UTTAR PRADESH. Quantity: 1 issued by. Submission Deadline: 28-02-2026 20: 00: 00. View full details and respond.

Documents 3

GeM-Bidding-8938786.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Power Generator - DG Set (up to 900 KVA)

E-municipalities - Eservices To Citizens And Employees Of Urban Local Bodies Of Uttar Pradesh

BAREILLY, UTTAR PRADESH

Posted: 27 November 2025
Closed: 12 December 2025
GEM

Power Generator - DG Set (up to 900 KVA)

Uttar Pradesh Police

SITAPUR, UTTAR PRADESH

Posted: 31 January 2025
Closed: 18 February 2025
GEM

Power Generator - DG Set (up to 900 KVA)

N/a

MIRZAPUR, UTTAR PRADESH

Posted: 10 October 2025
Closed: 29 October 2025
GEM

Power Generator - DG Set (up to 900 KVA)

Chief Engineer(dpi&roads),eic(civil), R&b,orissa, Bhubaneswar

ANGUL, ODISHA

Posted: 19 November 2025
Closed: 29 November 2025
GEM

Tamil Nadu Cooperative Milk Producers Federation Ltd DG Set Tender 900 KVA Tiruvannamalai 2025

Tamil Nadu Cooperative Milk Producers Federation L

TIRUVANNAMALAI, TAMIL NADU

Posted: 16 December 2025
Closed: 31 December 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Power Generator INSTALLATION CONFIGURATIONS Power Generator installation configurations as defined in CPWD General Specifications for Electrical works - Part VII (DG Set) Mobile (Trailer mounted) (Power Generators having an integral chassis fitted with wheels) "
OUTPUT CAPACITY RATING/ PHASE Nominal Rated Capacity (kVA) 62.5
OUTPUT CAPACITY RATING/ PHASE No of Phase (Single Phase-3-5kVA) (Single Phase or Three Phase-5 & 7-5, 10,15, 20, 25, 30 & 40 kVA) (Three Phase-50 to 900 kVA) Three Phase
ENGINE Rated Engine Power (kWm) 100 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator + Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience, 110 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience Or higher
ENGINE Type of Engine cooling Liquid Cooled
ENGINE Type of governer Mechanical, Electronic Or higher
ENGINE Number of cylinders (nos) 4
ENGINE Rated RPM of Engine (RPM) 1500
ENGINE Fuel High Speed Diesel (HSD)
ENGINE Starting voltage (volt) 12
ENGINE Salient Features of Engine Turbo Charged Engine, Naturally aspirated engine, Direct injection Fuel System, CRDi Fuel System, cold start upto (-20 deg c ), No derating applicable upto 4500 above MSL of altitude at 25 degree celcius, Indirect injection (IDI) Fuel System, Ambient working temperature upto 55 degree celcius.
GOVERNING CLASS "Maximum Change of Speed as a Percentage of Rated Speed on suddenly taking-off the rated load(Transient) " 15
GOVERNING CLASS "Maximum Recovery Time in Seconds on suddenly taking-off the rated load(Transient) " 15.0
GOVERNING CLASS Maximum Change of Speed as a Percentage of Rated Speed on suddenly taking-off the rated load(Permanent) 5
GOVERNING CLASS "Maximum Change of Speed as a Percentage of Rated Speed On a change of load, both on and off, by all steps of 25 percent of the rated load (Transient) " 4
GOVERNING CLASS "Maximum Recovery Time in Seconds on a change of load, both on and off, by all steps of 25 percent of the rated load(Transient) " 5.0
GOVERNING CLASS "Maximum Change of Speed as a Percentage of Rated Speed On a change of load, both on and off, by all steps of 25 percent of the rated load (Permanent) 1.5
ALTERNATOR Alternator Voltage Rating 415.0
ALTERNATOR Efficiency at rated Power factor at 75% of full Load 92.6 - 100.0 Or higher
ALTERNATOR Conformity to Indian Standard (for Alternator) Generally conforming to IS:13364 (Part-2) latest (Above 20 KVA)
ALTERNATOR Voltage Regulation Grade VG 3 Or higher
ALTERNATOR Alternator IP Rating IP 23 Or higher
ALTERNATOR Salient features of Alternator NA
CONTROL PANEL Control Panel Manual Control Panel
CONTROL PANEL Control Panel Location Inside the canopy
CONTROL PANEL IP Rating of Control Panel IP 53, IP 54, IP 55 Or higher
CONTROL PANEL Display meters in the control panel (with appropriate rating and accuracy class ) - inclusive in the scope of supply Voltmeter, Ammeter, Frequency meter, Power Factor meter, Multifunctional Digital display meter (displaying Voltage, Current, Frequency, Power Factor)
CONTROL PANEL Other devices in the control panel (with appropriate rating) - inclusive in the scope of supply Required switches and cutout, MCB, MCCB, Contactor, Circuit breaker, Battery charger, remote monitoring over internet with GSM modem.
CONTROL PANEL Displayed parameters/Features Engine Speed, Lube oil pressure, Coolant/cylinder head Temperature, Engine running hours, Engine battery voltage, Engine Running status, Generator Voltage (Ph-Ph), Generator Voltage (Ph-N), Generator Current (R, Y, B), Generator apparent Power (kVA), Generator active Power (kW), Powerfactor, Frequency, Fuel level, Event log, Control supply Voltage, Temperature scanner (RTD,BTD)
CONTROL PANEL Indicators Low Lube oil pressure, High water / coolant / cylinder head temperature, Low fuel level, Over speed
CONTROL PANEL Audio Alarm Low Lube oil pressure, High water / coolant / cylinder head temperature, Low fuel level, Over speed
ACOUSTIC ENCLOSURE Thickness of insulation 40.0 - 120.0 Or higher
ACOUSTIC ENCLOSURE Density of insulation (kg/cubic m) 80.0 - 100.0 Or higher
ACOUSTIC ENCLOSURE Noise level at 1 meter (dB) 75
Fuel Tank Fuel Tank Capacity 140.0
Fuel Tank Number of Fuel tank 1
Fuel Tank Fuel Tank Sheet Material Thickness(mm) 2, 3 Or higher
Fuel Tank Fuel Tank Features Fuel Tank capacity is sufficient for 8 hrs of running at full load, NA for 990 liter
BATTERY Battery Type & Specification "Low Maintenance free to IS: 14257 for high cranking performance"
BATTERY Battery capacity (Ah) 100
BATTERY No of batteries 1
SALIENT FEATURES Salient Features of Power Generator Glass window on Accoustic Enclosure in front of the Control Panel, Emergency Stop outside the Accoustic Enclosure
TRAILER Trailer Yes
TRAILER Pay load of the Trailer 2000 Or higher
TRAILER Number of Axlels 1
TRAILER Number of wheels Two wheeled
TRAILER Wheel Tyre size 16.0
TRAILER Brakes Hydraulic, Electrical Or higher
TRAILER Trailer Complying to CMVR act and Regulation Yes
SCOPE OF INSTALLATION Installation with installation - inclusive in the scope of supply Or higher
WARRANTY/SERVICES Warranty on Complete power genertor/DG Set 24, 36 Or higher
WARRANTY/SERVICES Warranty in running hours 5000.0 - 5000.0 Or higher
WARRANTY/SERVICES Number of preventive maintenance visits offered in an year during warranty period (Supply of all consumables is the buyer's responsibilty)* 1
TEST REPORTS Type of lab which carried out Test of Complete Product to prove the conformity of product as per specification Certificates required as per CPCB, Govt Lab, NABL accredited lab
TEST REPORTS Test report Available for (Test/approval) Type Approval Certificate for the specified rating of the Power Generator from any of the designated agency authorized by CPCB, COP Certificate for engine, Type test report and Endurance test report for Engine as per IS: 10001 latest / IS: 10002 latest, Type test report for Alternator as per IS:13364 (Part-1) latest / IS:13364 (Part-2) latest to prove conformity to the specifications
TEST REPORTS Agree to provide all relevant documents Test Report/supporting document /reports etc to the buyer at the time of bidding or on demand YES

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

9

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Corrigendum Updates

1 Update
#1

Update

23-Feb-2026

Extended Deadline

28-Feb-2026, 8:00 pm

Opening Date