Bhabha Atomic Research Centre has released a public tender for Ion selective electrode (Q3) in MUMBAI, MAHARASHTRA. Quantity: 1. Submission Deadline: 04-09-2026 13: 00: 00. Download documents and apply online.
Quantity
1
Bid Type
Two Packet Bid
Bid Validity
30 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
3 Days
EMD Required
No
MII Purchase Preference
No
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Ion selective electrode (Q3)
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Mumbai Suburban
Delivery Pincodes
400085
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Raman Kumar Mishra | 400085,BHABHA ATOMIC RESEARCH CENTRE (BARC), CENTRAL COMPLEX, TROMBAY, MUMBAI 400085 | Mumbai Suburban | Maharashtra | 400085 | 1 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Extended Deadline
04-Sep-2026, 7:30 am
Opening Date
04-Sep-2026, 8:00 am
Discover companies most likely to bid on this tender
Experience Criteria *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| Generic | Item Description | Only Ion Selective electrode with accessories, Only Electrode wthout accessories |
| Measurements | Possible Measurements | ions |
| Performance Parameter | Ion Electrodes | Fluoride ion |
| Performance Parameter | Features | Bench top model for analysis of all cations and anions at residual level, Atleast 5 methods per channel and allowing customized procedures to differentiate between tests and/or users, In places without power supply possibility of work with an external rechargeable battery, NA |
| Technical Specifications | Electrodes | Single Channel, 1 Electrode Supplied |
| Technical Specifications | Calibration Points-Min | 3 |
| Technical Specifications | Ion Meter Series | 500 Series, 600 Series, 700 Series, Others |
| Ion Selective Electrode | Ion measurement mode specifications | Automatic conversion of units -e.g. M/l to mg/l, Enables ion concentration measurements of monovalent, bivalent, negative and positive ions |
| mV - Rel mV | Relative Accuracy | +/-0.2 mV or 0.05%, whichever is greater, NA |
| pH Measuring Mode | pH mode specifications | Automatic detection of pH buffers and standards, their value may be set by the user, Automatic correction of the pH standard solution value changes, along with the temperature changes for NIST standards, what eliminates the necessity of warming up or cooling them down, NA |
| Temperature | Readable Units | Deg C, NA |
| Data Logging | Log function | Autohold, NA |
| Warranty | Warranty Duration | 0 - 36 |
| Documentation | Complete Tabular Details with specific Measurement chart as per Model | Yes |
| Certifications and Reports | Copies of reports and certifications to be furnished to buyer on demand at time of supplies | Yes |