Bid Publish Date
21-Aug-2026, 6:05 pm
Bid End Date
11-Sep-2026, 4:00 pm
EMD
₹17,200
Value
₹17,12,429
Location
Progress
A tender has been published for N/a Ceiling OT Light (V2) (Q2) in MUMBAI, MAHARASHTRA. Quantity: 1 by. Submission Deadline: 11-09-2026 16: 00: 00. Check eligibility and apply.
Quantity
1
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
3 Days
EMD Required
Yes
MII Purchase Preference
No
MSE Purchase Preference
No
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Min. Avg. Annual Turnover
6
Past Performance
80 %
Warranty Period
15 years
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Ceiling OT Light (V2) (Q2)
Advisory Bank
State Bank of India
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
90
Delivery Locations
1
Delivery Cities
Mumbai
Delivery Pincodes
400012
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Sheetal Sunil Patil | 400012,KEM hospital, Parel | Mumbai | Maharashtra | 400012 | 1 | 90 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Extended Deadline
11-Sep-2026, 10:30 am
Opening Date
11-Sep-2026, 11:00 am
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Ceiling OT Light |
| PRODUCT INFORMATION | Type of Ceiling OT Light | Double Dome, Triple Dome |
| PRODUCT INFORMATION | Light Emission of OT Light | LED |
| PRODUCT INFORMATION | Type of Lamp head | Single non winged round shape lamp head, Petaled Shaped / winged lamp head |
| PRODUCT INFORMATION | Minimum Diameter of lamp Head for main dome with tolerance ±20 (in mm) | 600 mm, 650 mm, 700 mm |
| PRODUCT INFORMATION | Minimum Diameter of Auxiliary dome with tolerance ±20 (in mm) | 600 mm, 650 mm, 700 mm |
| PRODUCT INFORMATION | Minimum Diameter of lamp Head for Second auxiliary dome with tolerance ±20 (in mm) | 400 mm, 500 mm, 550 mm, 600 mm, 650 mm, 700 mm, NA in case of Single dome and Double dome |
| PRODUCT INFORMATION | Material of Head Lamp | ABS/ Aluminium/ Poly Carbonate |
| PRODUCT INFORMATION | Light Intensity in Luminous at 1 meter distance | 150000 to 160000 (Major Dome) |
| PRODUCT INFORMATION | Colour Temperature in Kelvin (In between) | 3500 to 5000 K |
| PRODUCT INFORMATION | Minimum Life Span of LED for each dome (in hours) | 60000 Or higher |
| PRODUCT INFORMATION | Illuminated field diameter (in mm) | 180 to 300 mm or better |
| PRODUCT INFORMATION | Colour rendering index (CRI) | 95, 96, 98 Or higher |
| PRODUCT INFORMATION | Availability of control panels on the light assembly as well as away from it for adjustment of light intensity, illuminated area and for switching on and off, focusing , colour temp , etc | Yes |
| PRODUCT INFORMATION | Type of Control Panel | Manual, Touch Screen |
| PRODUCT INFORMATION | Light head should be so constructed as to provided optimum conditions for laminar flow | Yes |
| PRODUCT INFORMATION | User selectable intensity variation with digital display | 30 to 100% in minimum 5 or more steps |
| PRODUCT INFORMATION | Avaliability of back light or ENDO mode to allow appropriate visilibity of the screen | Yes |
| PRODUCT INFORMATION | Lamp head should have sterilizable handle at the center of the lamp head | Yes |
| PRODUCT INFORMATION | Depth of illumination of OT Light (in cms) | 100 to 140 cm or more for main and Satelite dome |
| PRODUCT INFORMATION | Availability of ON/OFF switch | Yes |
| PRODUCT INFORMATION | Lens of the domes should be interchangeable and removable, The glass should be scratch proof to optimize light penetration | Yes |
| PRODUCT INFORMATION | OT light should be provided with drip free spring arms for easy maneuverability , total lateral viewing of the patient as well as 360? rotation in main arm and light head | Yes |
| PRODUCT INFORMATION | Ergonomic or user friendly Handle to be provided | Yes |
| PRODUCT INFORMATION | Power Supply | 220-240 V, 50 Hz Single Phase |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license / Registration for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | Conformity to electrical safety standards | IEC 60601 or BIS equivalent |
| WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5.0 |