water baths
Navsari Agricultural University Navsari
Bid Publish Date
08-Jun-2026, 12:01 pm
Bid End Date
29-Jun-2026, 12:00 pm
Location
Progress
Quantity
2
Bid Type
Two Packet Bid
Oil And Natural Gas Corporation Limited announces a tender for water baths (Q3) in RAIGAD, MAHARASHTRA. Quantity: 2. Submission Deadline: 29-06-2026 12: 00: 00. Last date to apply is approaching fast!
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
water baths (Q3)
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Navsari Agricultural University Navsari
Anand Agricultural University
N/a
Principal. Government Polytechnic, Valsad
National Council For Cement And Building Materials (nccbm)
FARIDABAD, HARYANA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Water Bath Chamber Dimensions, Capacity and Construction | Water bath Chamber Capacity | over 30 to 34 Litre |
| Water Bath Chamber Dimensions, Capacity and Construction | Chamber Construction: | Double walled rectangular chamber with mineral wool/solid insulation material filling in between |
| Water Bath Chamber Dimensions, Capacity and Construction | Material of Outer Chamber Construction: | Epoxy / Powder coated Stainless Steel SS304 |
| Water Bath Chamber Dimensions, Capacity and Construction | Number of racks provided with Water bath unit | 0, 2, 4, 6, 8, 10, 12, 14 |
| Water Bath Chamber Dimensions, Capacity and Construction | Number of 75 mm diameter Holes provided: | 6 |
| Heating Arrangement Parameters | Heat source: | Heating shall be done by a immersion heater. |
| Heating Arrangement Parameters | Heating Capacity (>=): | 1500.0 |
| Control Panel and Display Unit | Control Panel has: | ON/Off Switch, Heating & Temprature (Set & Actual) Indicators, Power mains Indicator, Temperature controller, Circulation Controller (if Water bath has circulation facility) |
| Control Panel and Display Unit | Adjustable shaking frequency in rpm | 20-200, NA |
| Control Panel and Display Unit | Type of Temperature controller | Digital controller cum Indicator PID Based control Or higher |
| Control Panel and Display Unit | Water bath Display type: | Digital (numerical/application specific) backlit LCD display, LED |
| Control Panel and Display Unit | Integrated circulation pump for temperature homogeneity | Yes, No Or higher |
| Control Panel and Display Unit | Removable bottom plate and shaking inserts | Yes, No, N/A for shaking insert if the equipment provided without circulation feature Or higher |
| Water bath Temperature | Temperature range of bath chamber: | 5°C above ambient to 99.9°C |
| Water bath Temperature | Temperature control sensitivity: | ±0.5°C or better, ±0.2°C or better, ±0.1°C or better Or higher |
| Water bath Temperature | Least temperature increment Step available | 5 degree C, 1 degree C, 0.1 degree C, 0.01 degree C Or higher |
| Water bath Temperature | Temperature Accuracy: | ±1°C or better, ±0.5°C or better, ±0.2°C or better, ±0.1°C or better Or higher |
| Water bath Temperature | Safety Features: | Low fluid Alarm, High limit Alarm, Over temperature Alarm & cutoff, Redundant safety thermostat |
| Power Requirement, Certifications and Warranty | Power requirement: | 220 V 50 Hz Single Phase AC |
| Power Requirement, Certifications and Warranty | Availability of Test Report from Central Govt/NABL/ILAC accredited lab to prove conformity to specification | Yes, No |
| Power Requirement, Certifications and Warranty | Equipment has CE certification | Yes, No |
| Power Requirement, Certifications and Warranty | Warranty Period: | 3, 5 Or higher |
| Cover | Lid/cover Provided | Yes |
| Timer Unit | Timer Provided | Yes, No |
| Timer Unit | Timer Setting ( minimum increment step) | 0 - 300 |
| Miscellaneous Features | Drain plug in Chamber provided | Yes, No |
| Miscellaneous Features | Data Logging facility through (RS 232/USB/HDMI/Bluetooth etc) to computer available: | Yes, No |
| Miscellaneous Features | Drain screw for emptying of water bath | Yes Or higher |
| Miscellaneous Features | Seamless and waterproof keypad | Yes, No Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Central Mine Planning And Design Institute Limited
📍 NAGPUR, MAHARASHTRA
Directorate Of Medical Education Government Of Madhya Pradesh
📍 Satna, MADHYA PRADESH
Agricultural Scientists Recruitment Board
📍 CENTRAL DELHI, DELHI
Director Of School Education
📍 KARAIKAL, PUDUCHERRY
Bhakra Beas Management Board
📍 PANIPAT, HARYANA
Sign up now to access all documents
Main Document
OTHER
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS