| Category | Specification | Requirement |
|---|---|---|
| Standards | Confirmity to Manufactures Certification | ISO 9001 & ISO 13485 |
| Performance Parameters | type of microtome sectioning | Semi-automatic microtome |
| Performance Parameters | operation of microtome coarse feed | "electronically controlled motorized Slow: 300 μm/s, in 20 μm steps Fast: 900 μm/s " |
| Performance Parameters | Max Specimen size | 50x80mm |
| Performance Parameters | Section cutting via hand wheel | Advance and manual |
| Performance Parameters | Provision of hand wheel lock | Mechanical only |
| Performance Parameters | Chamber illumination light | bright white light |
| Performance Parameters | specimen cooling temperature in degree celcius in peltier element cooling area | minus 45 ±5 degree |
| Performance Parameters | Section thickness range in um | "1 to 100 1.0 μm – 5.0 μm in 0.5 μm steps 5.0 μm – 20.0 μm in 1.0 μm steps 20.0 μm – 60.0 μm in 5.0 μm steps 60.0 μm – 100.0 μm in 10.0 μm steps" |
| Performance Parameters | Trimming thickness range in um | "5 to 100 1,0 μm – 10,0 μm in 1,0 μm steps 10,0 μm – 20,0 μm in 2,0 μm steps 20,0 μm – 50,0 μm in 5,0 μm steps 50,0 μm – 100,0 μm in 10,0 μm steps " |
| Performance Parameters | Provision of automatic specimen retraction on return stroke | Yes |
| Standards Accessories | pkt of disposable blades | 2 |
| Standards Accessories | freezing medium 120ml bottle | 5 |
| Standards Accessories | Chucks | 15 |
| Additional Accessories | Provision of UPS | Yes |
| Additional Accessories | Backup time in hours | 1 |
| Miscellaneous Parameters | Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3 |
| Miscellaneous Parameters | Availability of test report from govt/ NABL/ILAC accredited lab covering all parameters | No |
| Miscellaneous Parameters | Number of installations of the machine in central / State/ PSU hospitals (Noe: sellers should supply a performance certificate of the device to the buyer if demanded after placement of order) | More than 3 |
| Miscellaneous Parameters | Copies of all certifications and reports to be provided to buyer on demand at time of supplies , | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Gujarat Cancer & Research Institute
N/a
📍 NEW DELHI, DELHI
Access all tender documents at no cost
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS