TenderDekho Logo
Active GEM

Contract Bidding Open For Automated HPLC System for Separation of complex mixtures in BELGAUM, KARNATAKA

Bid Publish Date

22-Jul-2026, 4:38 pm

Bid End Date

12-Aug-2026, 5:00 pm

Value

₹45,00,000

Progress

Issue22-Jul-2026, 4:38 pm
AwardPending
Explore all 6 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 14

Public procurement opportunity for Indian Council Of Medical Research (icmr) Automated HPLC System for Separation of complex mixtures (Q3) in BELGAUM, KARNATAKA. Quantity: 1 issued by. Submission Deadline: 12-08-2026 17: 00: 00. View full details and respond.

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Automated HPLC System for Separation of complex mixtures (Q3)

Advisory Bank

State Bank of India

ePBG Percentage

3%

ePBG Duration (Months)

38

Pre-Bid & Qualification

Pre-Bid Date

28-07-2026 16:00:00

Pre-Bid Venue

NITM ADMIN is inviting you to a scheduled Zoom meeting. Topic: pre bid meeting for procurement of analytical HPLC/UPLC Time: Jul 28, 2026 03:30 PM India Join Zoom Meeting https://zoom.us/j/2672156739? pwd=B87egm5jSvmJng7x4ScCEIppQK6G8M.1&omn=91025803744 Meeting chat link https://zoom.us/launch/jc/91025803744 Meeting ID: 267 215 6739 Passcode: NITM

Delivery Details

Max Delivery Days

60

Delivery Locations

1

Delivery Cities

(Opposite KLE Hospital)

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Manjit Sanjeev PatilNagar, (Opposite KLE Hospital)(Opposite KLE Hospital)--160-

Authority Records

MINISTRY OF HEALTH AND FAMILY WELFAREHEALTH RESEARCH DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 5

GeM-Bidding-9627457.pdf

Main Document

Other Documents

OTHER

Other Documents

OTHER

CATALOG-Specification-1

CATALOG Specification

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Standard parameter Instrument calibration standards IEC 17025, NA
Quaternary Gradient Solvent Delivery Unit with Degassing Unit Components of unit Quaternary Low-Pressure Gradient pump& Parallel Double Plunger
Quaternary Gradient Solvent Delivery Unit with Degassing Unit Number of solvents delivery 4
Quaternary Gradient Solvent Delivery Unit with Degassing Unit Flow rate setting range in ml/min 0.001 to 10
Quaternary Gradient Solvent Delivery Unit with Degassing Unit Flow rate accuracy ± 1 %
UV-Vis Detector UV-Vis Detector provided Yes Or higher
UV-Vis Detector Light source Deuterium lamp, NA if not provided, Tungsten Lamp
UV-Vis Detector Spectrum Band width in nm 4, 5, 6, 8, NA if not provided
UV-Vis Detector Wavelength range in nm 190 - 700
UV-Vis Detector Sampling Rate in Hz 100
UV-Vis Detector The flow cell must be temperature Controlled Yes, NA if not provided
UV-Vis Detector Wavelength accuracy in nm ± 1
UV-Vis Detector Wavelength reproducibility in nm ± 0.1
UV-Vis Detector Drift in AU/Hour less than 1 x 10-4
UV-Vis Detector Noise level in AU ± 2.5 x 10-6
UV-Vis Detector Ability to monitor and quantitative 2 wavelengths simultaneously Yes, NA if not provided
UV-Vis Detector Linearity in AU 2.5 or more
UV-Vis Detector Temperature control provided for Flow cell Yes, NA if not provided
UV-Vis Detector Temperature control range for flow cell in Degree Celsius 5 degree above room temp to 50 degree, NA if not provided
UV-Vis Detector flow cell path length in mm 10, NA if not provided
UV-Vis Detector Flow cell volume in ?l 10 - 15, NA if not provided, 16 - 20
Auto Sample Injector with cooler Injection Method Total volume sample injection
Auto Sample Injector with cooler Carry over of sample 0.005% or lower
Auto Sample Injector with cooler Injection precision in RSD less than 0.20 % RSD
Column Oven Type of column oven forced-air-circulation type
Software Operating Windows Win 10 or latest
Photo Diode Array (PDA) Detector Provision of Photo diode array Yes Or higher
Photo Diode Array (PDA) Detector PDA detector Wavelength range in nm 190- 800 or better
Photo Diode Array (PDA) Detector Number of Diodes 1024
Photo Diode Array (PDA) Detector PDA detector light source Deuterium lamp and Tungsten lamp
Photo Diode Array (PDA) Detector PDA detector Wavelength accuracy in nm ± 1
Photo Diode Array (PDA) Detector Data Rate in Hz 100, <100
Photo Diode Array (PDA) Detector Noise in AU less than ± 0.6 x 10-5 or lower
Photo Diode Array (PDA) Detector PDA detector Drift in AU/Hour less than 1 x 10-4
Photo Diode Array (PDA) Detector Temperature controlled flow cell in C 5 degree above room temp to 50 degree, NA if not provided
Photo Diode Array (PDA) Detector Flow cell Flow cell
Warranty & Reports Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) 5 Or higher
Warranty & Reports Number of installations in Central /State/PSU Govt Hospitals <3, >3
Warranty & Reports Availability of toll free facility for technical support maintained by OEM or authorized agencies Yes, No Or higher

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Additional Doc 2 (Requested in ATC)

9

Additional Doc 3 (Requested in ATC)

10

Additional Doc 4 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

11

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer