Progress
RAN/a invites bids for Intelligent analog addressable smoke detector complete with mounting base complete as required, Addressable manual call point complete as required, Addressable fire control module Relay Module as required, One time rectification and restoration of the fire alarm system, Micro processor based intelligent addressable main fire alarm panel, One time replacement and rectification of the Fire Alarm System, Supply laying and termination of 2Cx1 5 sq mm FRLS PVC insulated copper conductor, Supply and Installation of loop powered base addressable sounders complete with all fixing materials complete as required, One time rectification of the Fire Alarm System 2 loop which is having 153 nos of detectors and 10 Manual call points in BANGALORE, KARNATAKA. Quantity: 194. Submission Deadline: 15-07-2026 17: 00: 00. Submit your proposal before the deadline.
Start
19-Aug-2026, 11:00 am
End
20-Aug-2026, 11:00 am
Duration: 24 hours
Reverse Auction Document
✅ RA concluded. Check financial results for final rankings.
Quantity
194
Category
Intelligent analog addressable smoke detector complete with mounting base complete as required
Bid Type
Two Packet Bid
Bid Validity
90 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
H1-Highest Priced Bid Elimination
Tech Clarification Time
2 Days
EMD Required
No
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Past Performance
80 %
Warranty Period
3 days
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Intelligent analog addressable smoke detector complete with mounting base complete as required , Addressable manual call point complete as required , Addressable fire control module Relay Module as required , One time rectification and restoration of the fire alarm system , Micro processor based intelligent addressable main fire alarm panel , One time replacement and rectification of the Fire Alarm System , Supply laying and termination of 2Cx1 5 sq mm FRLS PVC insulated copper conductor , Supply and Installation of loop powered base addressable sounders complete with all fixing materials complete as required , One time rectification of the Fire Alarm System 2 loop which is having 153 nos of detectors and 10 Manual call points
Advisory Bank
HDFC Bank
ePBG Percentage
5%
ePBG Duration (Months)
14
Max Delivery Days
30
Delivery Locations
1
Delivery Cities
Bengaluru Urban
Delivery Pincodes
560065
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Prashanth K | 560065,National Centre for Biological Sciences NCBS-TIFR, GKVK CAMPUS, BELLARY ROAD, BANGALORE | Bengaluru Urban | Karnataka | 560065 | 40 | 30 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
Intelligent analog addressable smoke detector complete with mounting base complete as required
Supply Installation Testing and Commissioning of intelligent analog addressable smoke detector complete with mounting base complete as required The Detector shall be compatible for existing Notifier make FA System Make Notifier Warranty 1 year from the date of commissioning please refer the tender specifications
Addressable manual call point complete as required
Supply Installation Testing and Commissioning of addressable manual call pointcomplete as required. The Manual call point shall be compatible for existing Notifier make FA System Make NotifierWarranty 1 year from the date of commissioning please refer the tender specifications
Addressable fire control module Relay Module as required
Supply Installation Testing and Commissioning of addressable fire control module Relay Module as required The Control module shall be suitable for existing notifier make FA System Make Notifier Warranty 1 year from the date of commissioning please refer the tender specifications
One time rectification and restoration of the fire alarm system
One time rectification and restoration of the Fire Alarm System Make Notifier NFS 3030 comprising 10 loop fire alarm control panels 780 detectors 132 module and manual call points Location SLC Basement BMS Room NCBS The scope of work includes please refer the tender specifications
Micro processor based intelligent addressable main fire alarm panel
Supply Installation Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel Make Edwards 2 loop panel Central processing unit with 2 loop modules and capable of supporting not less than 240 devices including detectors and minimum 120 detectors per loop and loop length up to 2 km network communication card minimum 320 character graphics LCD Display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory EPROM power supply unit 230 5 V 50 Hz 48 Hrs back up with 12Volts 24 volts sealed Maintenance free batteries with automatic charger please refer the tender specifications
One time replacement and rectification of the Fire Alarm System
One time replacement and rectification of the Fire Alarm System 1 loop with 126 nos of detectors and 5 manual call points Make Edwards IO 500 Location Substation NCBS The scope of work includes please refer the tender specifications
Intelligent analog addressable smoke detector complete with mounting base complete as required
Supply Installation Testing and Commissioning of intelligent analog addressable smoke detector complete with mounting base complete as required Make Edwards Warranty 1 year from the date of commissioning please refer the tender specification
Addressable manual call point complete as required
Supply Installation Testing and Commissioning of addressable manual call point complete as required Make Edwards Warranty 1 year from the date of commissioning please refer the tender specification
Supply laying and termination of 2Cx1 5 sq mm FRLS PVC insulated copper conductor
Supply laying and termination of 2Cx1 5 sq mm FRLS PVC insulated copper conductor single core cable in existing surface recessed steel PVC conduit please refer the tender specifications
Supply and Installation of loop powered base addressable sounders complete with all fixing materials complete as required
Supply and Installation of loop powered base addressable sounders complete with all fixing materials complete as required Make Edwards
One time rectification of the Fire Alarm System 2 loop which is having 153 nos of detectors and 10 Manual call points
One time rectification of the Fire Alarm System 2 loop which is having 153 nos of detectors and 10 Manual call points Make Edwards Quick start EST3 Location ELC Reception NCBS The scope of work includes please refer the tender specifications
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Intelligent analog addressable smoke detector complete with mounting base complete as required | Supply Installation Testing and Commissioning of intelligent analog addressable smoke detector complete with mounting base complete as required The Detector shall be compatible for existing Notifier make FA System Make Notifier Warranty 1 year from the date of commissioning please refer the tender specifications | 40 | nos | prashanthk.ncbs | 30 | |
| 2 | Addressable manual call point complete as required | Supply Installation Testing and Commissioning of addressable manual call pointcomplete as required. The Manual call point shall be compatible for existing Notifier make FA System Make NotifierWarranty 1 year from the date of commissioning please refer the tender specifications | 10 | nos | prashanthk.ncbs | 30 | |
| 3 | Addressable fire control module Relay Module as required | Supply Installation Testing and Commissioning of addressable fire control module Relay Module as required The Control module shall be suitable for existing notifier make FA System Make Notifier Warranty 1 year from the date of commissioning please refer the tender specifications | 5 | nos | prashanthk.ncbs | 30 | |
| 4 | One time rectification and restoration of the fire alarm system | One time rectification and restoration of the Fire Alarm System Make Notifier NFS 3030 comprising 10 loop fire alarm control panels 780 detectors 132 module and manual call points Location SLC Basement BMS Room NCBS The scope of work includes please refer the tender specifications | 1 | nos | prashanthk.ncbs | 30 | |
| 5 | Micro processor based intelligent addressable main fire alarm panel | Supply Installation Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel Make Edwards 2 loop panel Central processing unit with 2 loop modules and capable of supporting not less than 240 devices including detectors and minimum 120 detectors per loop and loop length up to 2 km network communication card minimum 320 character graphics LCD Display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory EPROM power supply unit 230 5 V 50 Hz 48 Hrs back up with 12Volts 24 volts sealed Maintenance free batteries with automatic charger please refer the tender specifications | 1 | nos | prashanthk.ncbs | 30 | |
| 6 | One time replacement and rectification of the Fire Alarm System | One time replacement and rectification of the Fire Alarm System 1 loop with 126 nos of detectors and 5 manual call points Make Edwards IO 500 Location Substation NCBS The scope of work includes please refer the tender specifications | 1 | nos | prashanthk.ncbs | 30 | |
| 7 | Intelligent analog addressable smoke detector complete with mounting base complete as required | Supply Installation Testing and Commissioning of intelligent analog addressable smoke detector complete with mounting base complete as required Make Edwards Warranty 1 year from the date of commissioning please refer the tender specification | 20 | nos | prashanthk.ncbs | 30 | |
| 8 | Addressable manual call point complete as required | Supply Installation Testing and Commissioning of addressable manual call point complete as required Make Edwards Warranty 1 year from the date of commissioning please refer the tender specification | 10 | nos | prashanthk.ncbs | 30 | |
| 9 | Supply laying and termination of 2Cx1 5 sq mm FRLS PVC insulated copper conductor | Supply laying and termination of 2Cx1 5 sq mm FRLS PVC insulated copper conductor single core cable in existing surface recessed steel PVC conduit please refer the tender specifications | 100 | rmt | prashanthk.ncbs | 30 | |
| 10 | Supply and Installation of loop powered base addressable sounders complete with all fixing materials complete as required | Supply and Installation of loop powered base addressable sounders complete with all fixing materials complete as required Make Edwards | 5 | nos | prashanthk.ncbs | 30 | |
| 11 | One time rectification of the Fire Alarm System 2 loop which is having 153 nos of detectors and 10 Manual call points | One time rectification of the Fire Alarm System 2 loop which is having 153 nos of detectors and 10 Manual call points Make Edwards Quick start EST3 Location ELC Reception NCBS The scope of work includes please refer the tender specifications | 1 | nos | prashanthk.ncbs | 30 |
Experience Criteria
Past Performance
Certificate (Requested in ATC)
OEM Authorization Certificate
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer