Progress
Public procurement opportunity for All India Institute Of Medical Sciences (aiims) Arterial Blood Gas Analyzer (V2) (Q2) in PATNA, BIHAR. Quantity: 1 issued by. Submission Deadline: 01-09-2026 12: 00: 00. View full details and respond.
Quantity
1
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
H1-Highest Priced Bid Elimination
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Min. Avg. Annual Turnover
5
OEM Avg. Turnover
40
Past Performance
50 %
Warranty Period
2 years
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Arterial Blood Gas Analyzer (V2) (Q2)
Advisory Bank
Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
26
Max Delivery Days
45
Delivery Locations
1
Delivery Cities
Patna
Delivery Pincodes
801507
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Neeraj Dwivedi | 801507,AIIMS, Phulwarisarif, PATNA PIN-851507 | Patna | Bihar | 801507 | 1 | 45 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Arterial Blood Gas Analyzer |
| PRODUCT INFORMATION | Type of blood gas analyser | Bench Top |
| PRODUCT INFORMATION | Type of Technology | Cartridge (Multiple-Use) |
| PRODUCT INFORMATION | Parameters measured by blood gas analyser | pCO₂, pO₂, Na⁺, K⁺, pH and calculated parameters like HCO₃⁻, Base excess, TCO₂ |
| PRODUCT INFORMATION | Additional Parameters measurable by the blood gas analyser | Cl-, iCa, Glu, Hct, Lacate, Co-oximetry |
| PRODUCT INFORMATION | Cardiac Parameters measurable | Not available |
| PRODUCT INFORMATION | Neonatal Parameters | nBil |
| PRODUCT INFORMATION | Monitor type | LCD, LED Or higher |
| PRODUCT INFORMATION | Type of printer | Inbuilt Printer |
| PRODUCT INFORMATION | Cartridge / reagent to be used can be stored mostly at room temperature between 2-30 Degree C, Automatic calibration (hint: seller shall inform the exact details to buyer at the time of making the supplies) | Yes |
| PRODUCT INFORMATION | Shall have patient Bar Code facility, Ability to run a wide range of patient panels on one system | Yes |
| PRODUCT INFORMATION | Capability to transfer patient data to LIS/HIS | Yes |
| PRODUCT INFORMATION | Sample Volume in micro litre | ≤ 200 |
| PRODUCT INFORMATION | Power source | AC Mains |
| PRODUCT INFORMATION | Battery backup provided | Through UPS for 30 mins |
| CERTIFICATION AND REPORTS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATION AND REPORTS | Availability of valid device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATION AND REPORTS | Manufacturing unit certification | ISO:13485 (Latest) |
| CERTIFICATION AND REPORTS | Availability of Test Report for product as per Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATION AND REPORTS | Electrical Safety Standards | IEC/EN 60601-1 or equivalent BIS Standard |
| CERTIFICATION AND REPORTS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement | Yes |
| WARRANTY & SHELF LIFE | Warranty (including electrode and membrane etc as applicable for the analyzer offered) in years | 2.0 |
| WARRANTY & SHELF LIFE | Shelf life of the reagent / cartridges as applicable in months | 3 |
| WARRANTY & SHELF LIFE | On-board shelf life of reagent in weeks | 4 |
| MISCELLANEOUS REQUIREMENTS | OEM/Reseller shall ensure uninterrupted availability of all spares for 10 years | Yes |
| MISCELLANEOUS REQUIREMENTS | Availability of toll free facility for technical support maintened by OEM or authorized agencies | Yes |
| MISCELLANEOUS REQUIREMENTS | User/Technical/Maintenance manuals to be supplied in English in hard and soft copy | Yes |
| MISCELLANEOUS REQUIREMENTS | Details of equipments and procedures required for local calibration and routine maintenance to be supplied and advanced maintenance task documentation also to be furnished | Yes |
| MISCELLANEOUS REQUIREMENTS | List of important spares and accessories, with their part numbers to be supplied to the buyer at the time of supplying the equipment | Yes |
| MISCELLANEOUS REQUIREMENTS | Installation and Demonstration of equipment and training to be provided after completing supplies before acceptance | Yes |
| MISCELLANEOUS REQUIREMENTS | Principal Manufacturer must have direct Presence/approved service center In India | Yes |
| MISCELLANEOUS REQUIREMENTS | Calibration certificates as per NABH requirement | Yes |