Progress
Quantity
1118
Category
End termination 1
Bid Type
Two Packet Bid
A tender has been published for Employees State Insurance Corporation (esic) End termination 1, End termination 2, End termination 3, End termination 4, End termination 5, End termination 6, Cable Laying 1, Cable Laying 2, Cable Laying 3, Cable Laying 4, Cable Laying 5, Cable Laying 6, Straight through Joint 1, Straight through Joint 2, Straight through Joint 3, Straight through Joint 4, Straight through Joint 5, Straight through Joint 6, Straight through Joint 7, DD DB, SP MCB, DP MCB, Point wiring, PVC conduit 1, PVC conduit 2, Blanking plate, Ceiling rose, Modular board 1, Modular board 2, Modular board 3, Modular switch 1, Modular socket 1, Modular switch 2, Modular socket 2, Wiring 1, Wiring 2, Wiring 3, Wiring 4, ITC 1, Cu strip, Cu wire, Chequered plate, Danger Notice board, Exhaust fan, Earthing 1, Earthing 2, Dismentaling, PDB 1, PDB 2, PDB 3, ITC 2, LT cable 1, LT cable 2, LT cable 3, LT cable 4, LT cable 5, LT cable 6, Chemical earthing, Led light 1, Led light 2, hand glove, STC, FF1, FF2, Rubber mat, SLD, Allied civil job in KAMRUP, ASSAM. Quantity: 1118 by. Submission Deadline: 08-09-2025 19: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
End termination 1 , End termination 2 , End termination 3 , End termination 4 , End termination 5 , End termination 6 , Cable Laying 1 , Cable Laying 2 , Cable Laying 3 , Cable Laying 4 , Cable Laying 5 , Cable Laying 6 , Straight through Joint 1 , Straight through Joint 2 , Straight through Joint 3 , Straight through Joint 4 , Straight through Joint 5 , Straight through Joint 6 , Straight through Joint 7 , DD DB , SP MCB , DP MCB , Point wiring , PVC conduit 1 , PVC conduit 2 , Blanking plate , Ceiling rose , Modular board 1 , Modular board 2 , Modular board 3 , Modular switch 1 , Modular socket 1 , Modular switch 2 , Modular socket 2 , Wiring 1 , Wiring 2 , Wiring 3 , Wiring 4 , ITC 1 , Cu strip , Cu wire , Chequered plate , Danger Notice board , Exhaust fan , Earthing 1 , Earthing 2 , Dismentaling , PDB 1 , PDB 2 , PDB 3 , ITC 2 , LT cable 1 , LT cable 2 , LT cable 3 , LT cable 4 , LT cable 5 , LT cable 6 , Chemical earthing , Led light 1 , Led light 2 , hand glove , STC , FF1 , FF2 , Rubber mat , SLD , Allied civil job
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
End termination 1
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x25sqmm
End termination 2
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x35sqmm
End termination 3
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x50sqmm
End termination 4
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x25sqmm
End termination 5
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x70sqmm
End termination 6
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x95sqmm
Cable Laying 1
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required - upto 35sqmm
Cable Laying 2
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required - 35sqmm to 95 sqmm
Cable Laying 3
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required - 95sqmm to 185 sqmm
Cable Laying 4
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required -upto 35sqmm
Cable Laying 5
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required -35sqmm to 95 sqmm
Cable Laying 6
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required -95sqmm to 185 sqmm
Straight through Joint 1
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x25sqmm
Straight through Joint 2
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x35sqmm
Straight through Joint 3
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x50sqmm
Straight through Joint 4
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x70sqmm
Straight through Joint 5
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x95sqmm
Straight through Joint 6
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x120sqmm
Straight through Joint 7
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x240sqmm
DD DB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. - 8way DD
SP MCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C- curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
DP MCB
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 40 Amp DP MCB
Point wiring
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required (Grp. C)
PVC conduit 1
S&F of 20 mm PVC conduit
PVC conduit 2
S&F of 25 mm PVC conduit
Blanking plate
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Ceiling rose
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Modular board 1
Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc.as required -3 modular
Modular board 2
Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc.as required -6 modular
Modular board 3
Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc.as required -8 modular
Modular switch 1
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required -5/6A switch
Modular socket 1
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required -5/6A socket
Modular switch 2
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required -15/16A switch
Modular socket 2
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required -15/16A socket
Wiring 1
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 1.5sqmm
Wiring 2
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2.5sqmm
Wiring 3
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 4sqmm
Wiring 4
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 6sqmm
ITC 1
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Cu strip
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Cu wire
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required
Chequered plate
Providing,Cutting, making proper size of chequered plate for covering the existing trench complete with two coat primer painting with proper removing arrangement
Danger Notice board
250 mm X 200 mm L.T. danger notice plate
Exhaust fan
S&F of 450mm sweep AC exhaust fan
Earthing 1
Extra for providing masonery enclosure on the top of the earth electrode of overall size as per GeM bid NIT specification document
Earthing 2
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Dismentaling
Removal of old busbar, cables, connectores, light fittings, PVC conduits and refittment/ relocation, loading/ unloading, shifting/ postioning, supply of anciliaries for the Panel work as required, as per direction of the Engineer-in-charge
PDB 1
Supply of 2 mm thick CRC sheet make powder coated LT Power Distribution Panel comprises of two incomers of 315A and 250 Amps TPN MCCB with 315A and 250 A Change over switch, complete in all respect including making base as required on the floor (as per specifications of the NIT document) - Ex-Site
PDB 2
Supply of 2 mm thick CRC sheet make powder coated Feeder panel comprises of 250 Amps TPN MCCB, complete in all respect including making base as required on the floor (as per specifications of the NIT document) -Ex-site
PDB 3
APFC Panel - Supply of 100 KVAR Capacitor Panel comprising of 160A TP, 25KA, MCCB with Capacitor Bank of 5/10/15/20/25 KVAR TP capacitor with MCBs, Ammeter, sweep fan, indicator circuit, AUTO-MAINS switch etc. as per specifications of the NIT document
ITC 2
Installation, testing Commissioning of two Nos. PDBs at site as per direction of the Engineer-in-charge
LT cable 1
Supply of undernoted sizes of aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables etc. as required -25sqmm
LT cable 2
Supply of undernoted sizes of aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables etc. as required -35sqmm
LT cable 3
Supply of undernoted sizes of aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables etc. as required -50sqmm
LT cable 4
Supply of undernoted sizes of aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables etc. as required -70sqmm
LT cable 5
Supply of undernoted sizes of aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables etc. as required -95sqmm
LT cable 6
Supply of undernoted sizes of aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables etc. as required -120sqmm
Chemical earthing
Chemical earthing with 40 mm dia. 03 mtr length copper pipe & electrode, 25 Kg BFC chemical and pit cover complete with connection wires from pit to main switch board.( Make- JMV/ISG Global/ISI Marked) (RA sheet enclosed)
Led light 1
Supplying of Ceilling Mounted 20 Watt Indoor Round/ square type LED Down Light Fittings (SM251C LED20S- 6500 PSU WH) - (Philips/Havells/Crompton) (RA sheet enclosed)
Led light 2
Supplying of Ceilling Mounted 22 Watt Indoor type LED Light Fittings of 4 Feet Size Square type (Philips/Havells/Crompton) -BN021C LED22S PSU CW GR 9405 850 (Eq.) (RA sheet enclosed)
hand glove
11 KV grade Hand glove
STC
Shock treatment chart
FF1
Fire bucket with sand & Water with Stand (04 Buckets set)
FF2
Fire extinguisher CO2, 4.5Kg
Rubber mat
Supply and fixing of 11 KV grade Power rubber mat 2MtrX1Mtr
SLD
SLD colour print out in A1 size sheet with lamination in GQ paper
Allied civil job
Allied civil works for renovation of the Panel room as per the detailed BOQ and specification document enlcosed
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | End termination 1 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x25sqmm | 24 | each | cons-manish | 90 | |
| 2 | End termination 2 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x35sqmm | 24 | each | cons-manish | 90 | |
| 3 | End termination 3 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x50sqmm | 24 | each | cons-manish | 90 | |
| 4 | End termination 4 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x25sqmm | 24 | each | cons-manish | 90 | |
| 5 | End termination 5 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x70sqmm | 16 | each | cons-manish | 90 | |
| 6 | End termination 6 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x95sqmm | 16 | each | cons-manish | 90 | |
| 7 | Cable Laying 1 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required - upto 35sqmm | 55 | mtr | cons-manish | 90 | |
| 8 | Cable Laying 2 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required - 35sqmm to 95 sqmm | 65 | mtr | cons-manish | 90 | |
| 9 | Cable Laying 3 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required - 95sqmm to 185 sqmm | 75 | mtr | cons-manish | 90 | |
| 10 | Cable Laying 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required -upto 35sqmm | 30 | mtr | cons-manish | 90 | |
| 11 | Cable Laying 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required -35sqmm to 95 sqmm | 25 | mtr | cons-manish | 90 | |
| 12 | Cable Laying 6 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required -95sqmm to 185 sqmm | 35 | mtr | cons-manish | 90 | |
| 13 | Straight through Joint 1 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x25sqmm | 6 | each | cons-manish | 90 | |
| 14 | Straight through Joint 2 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x35sqmm | 6 | each | cons-manish | 90 | |
| 15 | Straight through Joint 3 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x50sqmm | 4 | each | cons-manish | 90 | |
| 16 | Straight through Joint 4 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x70sqmm | 4 | each | cons-manish | 90 | |
| 17 | Straight through Joint 5 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x95sqmm | 4 | each | cons-manish | 90 | |
| 18 | Straight through Joint 6 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x120sqmm | 6 | each | cons-manish | 90 | |
| 19 | Straight through Joint 7 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5x240sqmm | 6 | each | cons-manish | 90 | |
| 20 | DD DB | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. - 8way DD | 1 | each | cons-manish | 90 | |
| 21 | SP MCB | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C- curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 6 | each | cons-manish | 90 | |
| 22 | DP MCB | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 40 Amp DP MCB | 1 | each | cons-manish | 90 | |
| 23 | Point wiring | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required (Grp. C) | 12 | each | cons-manish | 90 | |
| 24 | PVC conduit 1 | S&F of 20 mm PVC conduit | 40 | mtr | cons-manish | 90 | |
| 25 | PVC conduit 2 | S&F of 25 mm PVC conduit | 30 | mtr | cons-manish | 90 | |
| 26 | Blanking plate | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | 4 | each | cons-manish | 90 | |
| 27 | Ceiling rose | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. | 4 | each | cons-manish | 90 | |
| 28 | Modular board 1 | Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc.as required -3 modular | 2 | each | cons-manish | 90 | |
| 29 | Modular board 2 | Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc.as required -6 modular | 4 | each | cons-manish | 90 | |
| 30 | Modular board 3 | Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc.as required -8 modular | 2 | each | cons-manish | 90 | |
| 31 | Modular switch 1 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required -5/6A switch | 12 | each | cons-manish | 90 | |
| 32 | Modular socket 1 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required -5/6A socket | 2 | each | cons-manish | 90 | |
| 33 | Modular switch 2 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required -15/16A switch | 2 | each | cons-manish | 90 | |
| 34 | Modular socket 2 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required -15/16A socket | 2 | each | cons-manish | 90 | |
| 35 | Wiring 1 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 1.5sqmm | 60 | mtr | cons-manish | 90 | |
| 36 | Wiring 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2.5sqmm | 40 | mtr | cons-manish | 90 | |
| 37 | Wiring 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 4sqmm | 30 | mtr | cons-manish | 90 | |
| 38 | Wiring 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 6sqmm | 15 | mtr | cons-manish | 90 | |
| 39 | ITC 1 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | 12 | each | cons-manish | 90 | |
| 40 | Cu strip | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) | 35 | mtr | cons-manish | 90 | |
| 41 | Cu wire | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required | 45 | mtr | cons-manish | 90 | |
| 42 | Chequered plate | Providing,Cutting, making proper size of chequered plate for covering the existing trench complete with two coat primer painting with proper removing arrangement | 90 | kg | cons-manish | 90 | |
| 43 | Danger Notice board | 250 mm X 200 mm L.T. danger notice plate | 6 | each | cons-manish | 90 | |
| 44 | Exhaust fan | S&F of 450mm sweep AC exhaust fan | 1 | each | cons-manish | 90 | |
| 45 | Earthing 1 | Extra for providing masonery enclosure on the top of the earth electrode of overall size as per GeM bid NIT specification document | 2 | each | cons-manish | 90 | |
| 46 | Earthing 2 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode | 2 | each | cons-manish | 90 | |
| 47 | Dismentaling | Removal of old busbar, cables, connectores, light fittings, PVC conduits and refittment/ relocation, loading/ unloading, shifting/ postioning, supply of anciliaries for the Panel work as required, as per direction of the Engineer-in-charge | 1 | ls | cons-manish | 90 | |
| 48 | PDB 1 | Supply of 2 mm thick CRC sheet make powder coated LT Power Distribution Panel comprises of two incomers of 315A and 250 Amps TPN MCCB with 315A and 250 A Change over switch, complete in all respect including making base as required on the floor (as per specifications of the NIT document) - Ex-Site | 1 | each | cons-manish | 90 | |
| 49 | PDB 2 | Supply of 2 mm thick CRC sheet make powder coated Feeder panel comprises of 250 Amps TPN MCCB, complete in all respect including making base as required on the floor (as per specifications of the NIT document) -Ex-site | 1 | each | cons-manish | 90 | |
| 50 | PDB 3 | APFC Panel - Supply of 100 KVAR Capacitor Panel comprising of 160A TP, 25KA, MCCB with Capacitor Bank of 5/10/15/20/25 KVAR TP capacitor with MCBs, Ammeter, sweep fan, indicator circuit, AUTO-MAINS switch etc. as per specifications of the NIT document | 1 | each | cons-manish | 90 | |
| 51 | ITC 2 | Installation, testing Commissioning of two Nos. PDBs at site as per direction of the Engineer-in-charge | 1 | each | cons-manish | 90 | |
| 52 | LT cable 1 | Supply of undernoted sizes of aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables etc. as required -25sqmm | 24 | mtr | cons-manish | 90 | |
| 53 | LT cable 2 | Supply of undernoted sizes of aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables etc. as required -35sqmm | 36 | mtr | cons-manish | 90 | |
| 54 | LT cable 3 | Supply of undernoted sizes of aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables etc. as required -50sqmm | 18 | mtr | cons-manish | 90 | |
| 55 | LT cable 4 | Supply of undernoted sizes of aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables etc. as required -70sqmm | 16 | mtr | cons-manish | 90 | |
| 56 | LT cable 5 | Supply of undernoted sizes of aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables etc. as required -95sqmm | 60 | mtr | cons-manish | 90 | |
| 57 | LT cable 6 | Supply of undernoted sizes of aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables etc. as required -120sqmm | 24 | mtr | cons-manish | 90 | |
| 58 | Chemical earthing | Chemical earthing with 40 mm dia. 03 mtr length copper pipe & electrode, 25 Kg BFC chemical and pit cover complete with connection wires from pit to main switch board.( Make- JMV/ISG Global/ISI Marked) (RA sheet enclosed) | 2 | each | cons-manish | 90 | |
| 59 | Led light 1 | Supplying of Ceilling Mounted 20 Watt Indoor Round/ square type LED Down Light Fittings (SM251C LED20S- 6500 PSU WH) - (Philips/Havells/Crompton) (RA sheet enclosed) | 4 | each | cons-manish | 90 | |
| 60 | Led light 2 | Supplying of Ceilling Mounted 22 Watt Indoor type LED Light Fittings of 4 Feet Size Square type (Philips/Havells/Crompton) -BN021C LED22S PSU CW GR 9405 850 (Eq.) (RA sheet enclosed) | 4 | each | cons-manish | 90 | |
| 61 | hand glove | 11 KV grade Hand glove | 1 | pair | cons-manish | 90 | |
| 62 | STC | Shock treatment chart | 2 | each | cons-manish | 90 | |
| 63 | FF1 | Fire bucket with sand & Water with Stand (04 Buckets set) | 1 | each | cons-manish | 90 | |
| 64 | FF2 | Fire extinguisher CO2, 4.5Kg | 4 | each | cons-manish | 90 | |
| 65 | Rubber mat | Supply and fixing of 11 KV grade Power rubber mat 2MtrX1Mtr | 3 | each | cons-manish | 90 | |
| 66 | SLD | SLD colour print out in A1 size sheet with lamination in GQ paper | 2 | each | cons-manish | 90 | |
| 67 | Allied civil job | Allied civil works for renovation of the Panel room as per the detailed BOQ and specification document enlcosed | 1 | job | cons-manish | 90 |
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | FIRE EQUIPMENTS SUPPLY AGENCY. Under PMA | - | 08-09-2025 08:53:17 | |
| 2 | GUHA SCIENTIFIC AGENCY Under PMA | - | 08-09-2025 14:40:02 | |
| 3 | J.D ENTERPRISE Under PMA | - | 08-09-2025 10:47:38 | |
| 4 | SANLEC AUTOMATION PRIVATE LIMITED Under PMA | - | 06-09-2025 13:10:54 |
| Rank | Seller | Price | Item |
|---|---|---|---|
| L1 | FIRE EQUIPMENTS SUPPLY AGENCY.(MSE,MII)( MSE Social Category:General ) Under PMA | Item Categories : End termination 1,End termination 2,End termination 3,End termination 4,End termination 5,End termi | |
| L2 | GUHA SCIENTIFIC AGENCY (MSE,MII)( MSE Social Category:General ) Under PMA | Item Categories : End termination 1,End termination 2,End termination 3,End termination 4,End termination 5,End termi | |
| L3 | J.D ENTERPRISE (MSE,MII)( MSE Social Category:SC ) Under PMA | Item Categories : End termination 1,End termination 2,End termination 3,End termination 4,End termination 5,End termi |
Please sign in or create an account to view contract details and download result documents.
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS