TenderDekho Logo
GEM

Bids are Invited For Supply of 3 Phase 415V MCC Panel 1, IEC61439 compliant,Installation, testing and commissioning of I

Bid Publish Date

04-Nov-2024, 9:22 am

Bid End Date

25-Nov-2024, 10:00 am

EMD

₹82,000

Progress

Issue04-Nov-2024, 9:22 am
Technical24-11-2024 21:54:32
Financial
AwardPending
Explore all 3 tabs to view complete tender details

Quantity

4480

Categories 79

Semiconductor Laboratory has released a public tender for Supply of 3 Phase 415V MCC Panel 1, IEC61439 compliant, Installation, testing and commissioning of IEC61439 compliant, Supply of 3 Phase 415V MCC Panel 2, IEC61439 compliant, Supply of 3 Phase 415V MCC Panel 3, IEC61439 compliant, Supply of 3C x 25 Sq. mm, Stranded Copper Conduct, Laying of 3C x 25 Sq. mm, Stranded Copper Conduct, Supply of 3C x 10 Sq. mm, Stranded Copper Conduct, Laying of 3C x 10 Sq. mm, Stranded Copper Conduct, Supply of 4C x 6 Sq. mm, Stranded Copper Conduct, Laying of 4Cx 6 Sq. mm, Stranded Copper Conduct, Supply of 3C x 2. 5 Sq. mm, Stranded Copper Conduct, Laying of 3Cx 2. 5 Sq. mm, Stranded Copper Conduct, Supply of 12Cx1. 5. sq mm, 1. 1 KV grade, XLPE insulated, Laying and fixing of one number 12Cx1. 5Sqmm PVC insulated, Supply of indo or end termination 3Cx25 sq. mm, Making of indo or end termination 3Cx25 sq. mm, Supply of indo or end termination 3Cx10 sq. mm, Making of indo or end termination 3Cx10 sq. mm, Supply of indo or end termination for 4Cx6, Making of indo or end termination 4Cx6 sq. mm, Supply of indo or end termination 3Cx2. 5 sq. mm, Making of indo or end termination 3Cx2. 5 sq. mm, Supply of 12Cx1. 5. sq mm Size indo or end termination, Making of 12Cx1. 5Sqmm size indo or end termination, Supply of indo or end terminationr 3. 5C x 240 sq. mm, Making of indo or end termination 3. 5C x 240 sq. mm, Supply of indo or end termination 3. 5C x 120 sq. mm, Making of indo or end termination 3. 5C x 120 sq. mm, Rerouting of the 3. 5Cx 240Sqmm stranded Aluminium, Laying and fixing of one number PVC insulated and PVC, Supply of 300 mm W x 50 mm D x1. 6 mm T size, Installation of 300 mm W x 50 mm D x1. 6 mm, Supply of 150mm W x50 mm D x1. 6 mm T size, Installation of 150mm W x50 mm D x1. 6 mm, Supply of 50mm W x50 mm D x1. 6 mm T size, Installation of 50mm W x50 mm D x1. 6 mm T size, Supply of 25 mm X 5 mm GI strip, Fixing 25 mm X 5 mm GI strip, Providing of 8 SWG dia G. I. wire on surface, Fixing 8 SWG dia G. I. wire on surface, Supply of outdo or type junction box 630mm x 300mm x 250mm, ITC of outdo or type junction box 630mm x 300mm x 250mm, Supply of Earthing with maintenance free copper coated Earth rod, Installtion of Maintenance free earth pit including necessary civil works, Supplying of 25 mm X 5 mm G. I strip, Laying of 25 mm X 5 mm G. I strip at 0. 50, Dismantling of existing MCC Panel Approx length 4. 5 meter, Dismantling of existing MCC Panel Approx length 1 meter, Dismantling of the existing power and control cabless. Quantity: 4480. Submission Deadline: 25-11-2024 10: 00: 00. Download documents and apply online.

Documents 5

GeM-Bidding-7060511.pdf

Main Document

BOQ Document

BOQ

BOQ Document

BOQ

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

SITC of free standing, outdoor cubicle type microprocessor based AMF panel 30 KVA,SITC of free stan

Bharat Sanchar Nigam Limited Portal(bsnl)

KOLLAM, KERALA

Posted: 8 October 2025
Closed: 29 October 2025
GEM

Supply of copper conductor fexible cableof size 1.5 sq.mm,Supply of copper conductor fexible cable

Airports Authority Of India

DIMAPUR, NAGALAND

Posted: 21 January 2025
Closed: 3 February 2025
GEM

1 core,1 sqmm, ISI marked, 1.1KV, FRLS PVC Insulated, Multi Stranded Copper Wire,1 core,2.5 sqmm,IS

Irel (india) Limited

GANJAM, ODISHA

Posted: 18 June 2025
Closed: 14 July 2025
GEM

Airports Authority Of India Earthing & Electrical Supplies Tender Bhopal Madhya Pradesh 2025

Ans,finance,hr,engineering,tech,ops,commercial,general Store,it

BHOPAL, MADHYA PRADESH

Posted: 28 October 2025
Closed: 18 November 2025
GEM

400A Incomer Fire Panel,300 mm GI Perforated Cable tray,150 mm GI Perforated Cable tray,300 mm GI P

N/a

GURGAON, HARYANA

Posted: 2 June 2025
Closed: 23 June 2025
GEM

Bill of Quantities (BOQ) 51 Items

Item # Title Description Quantity Unit Consignee Delivery (Days)
1 Supply of 3 Phase 415V MCC Panel 1, IEC61439 compliant Supply of 3 Phase 415V MCC Panel 1, IEC61439 compliant, flo or mounted detailed as per enclosed specifications and SLD. Make ABB or Siemens or Schneider or Legrand or Land T or Rockwell Automation or its auth or ized TTA IEC61439 vend or as per enclosed approved vend or list. 1 no [email protected] 140
2 Installation, testing and commissioning of IEC61439 compliant Installation, testing and commissioning of IEC61439 compliant, flo or mounted new MCC Panel 1 detailed guideline as per enclosed specifications. 1 no [email protected] 140
3 Supply of 3 Phase 415V MCC Panel 2, IEC61439 compliant Supply of 3 Phase 415V MCC Panel 2, IEC61439 compliant, flo or mounted detailed as per enclosed specifications and SLD. Make ABB or Siemens or Schneider or Legrand or Land T or Rockwell Automation or its auth or ized TTA IEC61439 vend or s as per enclosed approved vend or list. 1 no [email protected] 140
4 Installation, testing and commissioning of IEC61439 compliant Installation, testing and commissioning of IEC61439 compliant, flo or mounted new MCC Panel 2 detailed guideline as per enclosed specifications. 1 no [email protected] 140
5 Supply of 3 Phase 415V MCC Panel 3, IEC61439 compliant Supply of 3 Phase 415V MCC Panel 3, IEC61439 compliant, flo or mounted detailed as per enclosed specifications and SLD. Make ABB or Siemens or Schneider or Legrand or Land T or Rockwell Automation or its auth or ized TTA IEC61439 vend or s as per enclosed approved vend or list. 1 no [email protected] 140
6 Installation, testing and commissioning of IEC61439 compliant Installation, testing and commissioning of IEC61439 compliant, flo or mounted new MCC Panel detailed guideline as per enclosed specifications. 1 no [email protected] 140
7 Supply of 3C x 25 Sq. mm, Stranded Copper Conduct Supply of 3C x 25 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall FRLS PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I with latest amendment as required. Note Party to submit the test certificate f or the cable. Make Finolex or Havells or KEI or Polycab or RPG or CCI. 500 mtr [email protected] 140
8 Laying of 3C x 25 Sq. mm, Stranded Copper Conduct Laying of 3C x 25 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I on existing cable tray or wall or surface or as required. Note Existing cable tray is at an elevation of approx. 3 4 meter. 500 mtr [email protected] 140
9 Supply of 3C x 10 Sq. mm, Stranded Copper Conduct Supply of 3C x 10 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall FRLS PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I with latest amendment as required. Note Party to submit the test certificate f or the cable. Make Finolex or Havells or KEI or Polycab or RPG or CCI. 200 mtr [email protected] 140
10 Laying of 3C x 10 Sq. mm, Stranded Copper Conduct Laying of 3C x 10 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I on existing cable tray or wall or surface or as required. Note Existing cable tray is at an elevation of approx. 3 4 meter. 200 mtr [email protected] 140
11 Supply of 4C x 6 Sq. mm, Stranded Copper Conduct Supply of 4C x 6 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall FRLS PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I with latest amendment as required. Note Party to submit the test certificate f or the cable. Make Finolex or Havells or KEI or Polycab or RPG or CCI. 500 mtr [email protected] 140
12 Laying of 4Cx 6 Sq. mm, Stranded Copper Conduct Laying of 4Cx 6 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I on existing cable tray or wall or surface or as required. Note Existing cable tray is at an elevation of approx. 3 4 meter. 500 mtr [email protected] 140
13 Supply of 3C x 2.5 Sq. mm, Stranded Copper Conduct Supply of 3C x 2.5 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall FRLS PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I with latest amendment as required. Note Party to submit the test certificate f or the cable. Make Finolex or Havells or KEI or Polycab or RPG or CCI. 100 mtr [email protected] 140
14 Laying of 3Cx 2.5 Sq. mm, Stranded Copper Conduct Laying of 3Cx 2.5 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I on existing cable tray or wall or surface or as required. Note Existing cable tray is at an elevation of approx. 3 4 meter. 100 mtr [email protected] 140
15 Supply of 12Cx1.5.sq mm, 1.1 KV grade, XLPE insulated Supply of 12Cx1.5.sq mm, 1.1 KV grade, XLPE insulated, and overall sheathed, stranded copper conduct or , flat steel strip or wire armoured control cables conf or ming to IS 7098 or Part I with latest amendments and of following sizes. Note The cables or drum shall bear ISI certification mark and party to submit the test certificate f or cables. Make Finolex or Havells or RPG or Polycab or Glostar or Lapp or KEI or Rallision Note Party to submit the type test certificate f or the cables. 400 mtr [email protected] 140
16 Laying and fixing of one number 12Cx1.5Sqmm PVC insulated Laying and fixing of one number 12Cx1.5Sqmm PVC insulated and PVC sheathed or XLPE Control cable of 1.1 KV grade on existing cable tray as required. 400 mtr [email protected] 140
17 Supply of indo or end termination 3Cx25 sq.mm Supply of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 3Cx25 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required Make Dowells or 3M or Hex or Comat or Johnson 20 no [email protected] 140
18 Making of indo or end termination 3Cx25 sq.mm Making of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 3Cx25 sq.mm size of XLPE insulated, PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required 20 no [email protected] 140
19 Supply of indo or end termination 3Cx10 sq.mm Supply of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 3Cx10 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required Make Dowells or 3M or Hex or Comat or Johnson 12 no [email protected] 140
20 Making of indo or end termination 3Cx10 sq.mm Making of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 3Cx10 sq.mm size of XLPE insulated, PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required 12 no [email protected] 140
21 Supply of indo or end termination for 4Cx6 Supply of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 4Cx6 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required Make Dowells or 3M or Hex or Comat or Johnson 24 no [email protected] 140
22 Making of indo or end termination 4Cx6 sq.mm Making of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 4Cx6 sq.mm size of XLPE insulated, PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required 24 no [email protected] 140
23 Supply of indo or end termination 3Cx2.5 sq.mm Supply of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 3Cx2.5 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required Make Dowells or 3M or Hex or Comat or Johnson 2 no [email protected] 140
24 Making of indo or end termination 3Cx2.5 sq.mm Making of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 3Cx2.5 sq.mm size of XLPE insulated, PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required 2 no [email protected] 140
25 Supply of 12Cx1.5.sq mm Size indo or end termination Supply of 12Cx1.5.sq mm Size indo or end termination with nickel coated, brass double compression gland and Copper lugs f or Copper conduct or , XLPE insulated, 1.1 KV grade cable as required, Make Dowells or Commet or Hex or 3M 20 no [email protected] 140
26 Making of 12Cx1.5Sqmm size indo or end termination Making of 12Cx1.5Sqmm size indo or end termination with nickel coated, brass double compression gland and Copper lugs f or Copper conduct or , XLPE insulated, 1.1 KV grade control cable as required, 20 no [email protected] 140
27 Supply of indo or end terminationr 3.5C x 240 sq.mm Supply of indo or end termination with nickel coated brass double compression gland and Aluminium lugs f or 3.5C x 240 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall PVC outer sheathed copper conduct or cable of 1.1 KV grade as required. Make Dowells or 3M or Hex or Comat or Johnson 2 no [email protected] 140
28 Making of indo or end termination 3.5C x 240 sq.mm Making of indo or end termination with nickel coated brass double compression gland and Aluminium lugs f or 3.5C x 240 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall PVC outer sheathed copper conduct or cable of 1.1 KV grade as required. 2 no [email protected] 140
29 Supply of indo or end termination 3.5C x 120 sq.mm Supply of indo or end termination with nickel coated brass double compression gland and Aluminium lugs f or 3.5C x 120 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall PVC outer sheathed copper conduct or cable of 1.1 KV grade as required. Make Dowells or 3M or Hex or Comat or Johnson 2 no [email protected] 140
30 Making of indo or end termination 3.5C x 120 sq.mm Making of indo or end termination with nickel coated brass double compression gland and Aluminium lugs f or 3.5C x 120 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall PVC outer sheathed copper conduct or cable of 1.1 KV grade as required. 2 no [email protected] 140
31 Rerouting of the 3.5Cx 240Sqmm stranded Aluminium Rerouting of the 3.5Cx 240Sqmm stranded Aluminium, XLPE insulated, extruded inner PVC sheet, flat strip armoured and overall PVC outer sheathed 1.1 KV grade cable on the existing cable tray as required. 10 mtr [email protected] 140
32 Laying and fixing of one number PVC insulated and PVC Laying and fixing of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of size above 95 sq. mm and upto 185 sq. mm clamped with 25 or 40x3mm MS flat clamp on cable tray as required. Note Cable shall be provided by SCL free of cost. 30 mtr [email protected] 140
33 Supply of 300 mm W x 50 mm D x1.6 mm T size Supply of 300 mm W x 50 mm D x1.6 mm T size, hot dipped galvanised Iron ladder type cable tray including supply of supp or t materials such as unistrut, clamping rods, nuts, bolts, washers etc. as required. Make CABLOFIL or OBO or Land T or Profab or Sintex or equivalent. 30 mtr [email protected] 140
34 Installation of 300 mm W x 50 mm D x1.6 mm Installation of 300 mm W x 50 mm D x1.6 mm T size, perf or ated,hot dipped galvanised Iron ladder type cable tray including supp or t materials such as unistrut, clamping rods, nuts, bolts, washers etc. and min or civil w or k as required. 30 mtr [email protected] 140
35 Supply of 150mm W x50 mm D x1.6 mm T size Supply of 150mm W x50 mm D x1.6 mm T size of perf or ated pre galvanised finish galvanising as per IS 277 Cable Tray with perf or ation not m or e than 17.5 percent in convenient section, joined with connect or s, with clamps of cable tray including supply of supp or t materials such as unistruds, clamping rids etc. as required Make Sintex or Land T or 3M or Profab or Legrand or OBO Bettermann or equivalent 50 mtr [email protected] 140
36 Installation of 150mm W x50 mm D x1.6 mm Installation of 150mm W x50 mm D x1.6 mm T size of perf or ated pre galvanised finish Cable Tray including min or civil w or k as required 50 mtr [email protected] 140
37 Supply of 50mm W x50 mm D x1.6 mm T size Supply of 50mm W x50 mm D x1.6 mm T size of perf or ated pre galvanised finish galvanising as per IS 277 Cable Tray with perf or ation not m or e than 17.5 percent in convenient section, joined with connect or s, with clamps of cable tray including supply of supp or t materials such as unistruds, clamping rids etc. as required Make Sintex or Land T or 3M or Profab or Legrand or OBO Bettermann or equivalent 50 mtr [email protected] 140
38 Installation of 50mm W x50 mm D x1.6 mm T size Installation of 50mm W x50 mm D x1.6 mm T size of perf or ated pre galvanised finish Cable Tray including min or civil w or k as required 50 mtr [email protected] 140
39 Supply of 25 mm X 5 mm GI strip Supply of 25 mm X 5 mm GI strip along with G.I. nut, bolt, spring, washer etc. as required f or earthing of Electrical panel. Make Reputed. 50 mtr [email protected] 140
40 Fixing 25 mm X 5 mm GI strip Fixing 25 mm X 5 mm GI strip f or earthing on surface or in recess f or connections etc. as required,including connection or terminating with G.I. nut, bolt, spring, washer etc. as required. Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt and spring washer spaced at 50mm . 50 mtr [email protected] 140
41 Providing of 8 SWG dia G.I. wire on surface Providing of 8 SWG dia G.I. wire on surface or in recess f or loop earthing as required. Make Reputed 100 mtr [email protected] 140
42 Fixing 8 SWG dia G.I. wire on surface Fixing 8 SWG dia G.I. wire on surface or in recess f or loop earthing as required. 100 mtr [email protected] 140
43 Supply of outdo or type junction box 630mm x 300mm x 250mm Supply of outdo or type junction box having size 630mm x 300mm x 250mm, MS sheet , single front construction, Powder coated IP 54, non compartmental, 3 mm thick removable gland plate, f or bottom entry, lug and ferrules at both side of control wiring, Aluminium name plate on front hinged do or , 2 nos earth stud with 100 no of elmex type malamine terminal blocks etc. Note Necessary hardware such as fastener, MS powder coated frame etc f or installion of the Junction Box on wall shall be supplied by the vend or . Make As per Approved Panel List attached . 2 no [email protected] 140
44 ITC of outdo or type junction box 630mm x 300mm x 250mm Installation , testing Commissioning of outdo or type junction box 630mm x 300mm x 250mm on wall as required. 2 no [email protected] 140
45 Supply of Earthing with maintenance free copper coated Earth rod Supply of Earthing with maintenance free copper coated Earth rod of 3 Mtr length 20 mm dia earth rod with necessary coupler and connect or , universal clamps, inspection chamber,earth conductivity enhancing mineral compound of required quantity and providing earth chamber including material to interconnect with earth strips complete as required as per IS 60364 and IS 3043 with latest amendments. Make OBO Bettermann or Terec or Erico or L or ess or Ashlok or JMV lps or equivalent 2 no [email protected] 140
46 Installtion of Maintenance free earth pit including necessary civil works Installtion of Maintenance free earth pit including necessary civil w or ks such as excavation, laying of chemcials, installing the rod, necessary holes, interconnect with earth strips complete, making the chamber and paintaing the same with green colour as required. 2 no [email protected] 140
47 Supplying of 25 mm X 5 mm G.I strip Supplying of 25 mm X 5 mm G.I strip including necessary hardware such as G.I. nut, bolt, spring, washer etc. as required. 50 meter [email protected] 140
48 Laying of 25 mm X 5 mm G.I strip at 0.50 Laying of 25 mm X 5 mm G.I strip at 0.50 including connection or terminating with G.I. nut, bolt, spring, washer etc. as required. Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt and spring washer spaced at 50mm 50 meter [email protected] 140
49 Dismantling of existing MCC Panel Approx length 4.5 meter Dismantling of existing MCC Panel Approx length 4.5 meter located at Ground flo or of ESG Building after dismantling of the Power or Control cables and shifting the same at the designated location within SCL permises 1 no [email protected] 140
50 Dismantling of existing MCC Panel Approx length 1 meter Dismantling of existing MCC Panel Approx length 1 meter located at Ground flo or of ESG Building after dismantling of the Power or Control cables and shifting the same at the designated location within SCL permises 1 no [email protected] 140
51 Dismantling of the existing power and control cabless Dismantling of the existing power and control cabless upto size of 25 Sqmm from cable tray at a height of 3 4 meter and shifting the same to the designated location in SCl permises. 200 meter [email protected] 140

Technical Results

S.No Seller Item Date Status
1B S ENGINEERING & CONTRACTORS   Under PMA-24-11-2024 21:54:32Qualified
2INNOVATION TECHNOLOGIES   Under PMA-24-11-2024 21:39:02Qualified
3M/S INDUSTRIAL CONTROL SOLUTIONS   Under PMA-24-11-2024 18:59:26Qualified

Financial Results

Rank Seller Price Item
L1Innovation Technologies(MII)   Under PMA₹45,05,750Item Categories : Supply of 3 Phase 415V MCC Panel 1, IEC61439 compliant,Installation, testing and commissioning of I
L2B S ENGINEERING & CONTRACTORS (MSE,MII)( MSE Social Category:OBC )    Under PMA₹55,43,564Item Categories : Supply of 3 Phase 415V MCC Panel 1, IEC61439 compliant,Installation, testing and commissioning of I
L3M/S INDUSTRIAL CONTROL SOLUTIONS (MSE,MII)( MSE Social Category:General )    Under PMA₹1,72,61,020Item Categories : Supply of 3 Phase 415V MCC Panel 1, IEC61439 compliant,Installation, testing and commissioning of I

Frequently Asked Questions

What are the eligibility requirements for participation in the SITC of MOTOR CONTROL PANEL tender?

The eligibility requirements include being a registered entity on the GeM portal with relevant certifications. Bidders must showcase prior experience in the installation of MCC panels and be financially stable to handle the project workload.

What certificates are required to submit with the tender application?

Bidders are required to demonstrate compliance with relevant technical standards by submitting certificates that verify their experience in electrical works, quality assurance documentation, and any necessary ISO certifications.

How do I register for participating in the tender on the GeM platform?

To register for the tender, bidders must create an account on the GeM portal, verify their business details, and complete the registration form. Upon successful registration, they can searc the tenders and submit bids accordingly.

What document formats are accepted for submission?

All documents submitted must be in PDF format, ensuring they are clear and legible. Additional documents supporting technical and financial bids should also be included in this format.

What are the technical specifications required for the MCC panels?

The technical specifications mandate that all MCC panels must comply with IEC61439 standards. This includes parameters around the construction, safety measures, load handling, and fire safety protocols.

What quality standards must be adhered to during execution?

Bidders are obligated to adhere to industry-standard quality measures including IEC guidelines throughout the installation and maintenance of the MCC panels.

Are there any compliance requirements that need to be met?

Yes, all participating bidders must comply with local laws and regulations related to electrical work, including those outlined in safety and construction standards pertinent to MCC installation.

What is the Earnest Money Deposit (EMD) amount for this tender?

The Earnest Money Deposit (EMD) required is ₹82,000. This must be submitted as part of the bid proposal to ensure commitment to the tender's conditions.

What are the performance security requirements?

The successful bidder will be required to submit a performance security amount, typically a percentage of the contract value, to ensure fulfillment of contractual obligations.

What are the payment terms once the tender is awarded?

Payment terms will be detailed in the contract but typically involve milestone payments upon completion of specific phases of the project, following approval from the Department of Electronics and Information Technology.

How will the prices be evaluated during the selection process?

Pricing will be evaluated based on competitiveness and compliance with bid requirements set forth in the tender documentation. The lowest bid that meets all criteria will be preferred.

What submission methods are permitted for tender applications?

Bidders must submit their applications electronically via the GeM portal, ensuring all required documentation is uploaded before the submission deadline.

When will results of the evaluation be announced?

Results of the evaluation process will be announced as soon as the tender committee has finalized the assessments and approvals, typically after opening the bids.

What benefits do MSEs receive in this tender?

MSEs may enjoy concessions related to bid evaluation and documentation submission requirements, aiding in enhancing their participation in the tender process.

Is there any provision for startups in this tender?

Yes, the Ministry provides specific provisions to support startups, including reduced financial barriers and simplified compliance processes.

How does the tender comply with ‘Make in India’ policies?

The tender encourages local procurement and sourcing of materials to promote domestic manufacturing and reduce import dependency, aligning with the 'Make in India' initiative.

What are local content and procurement rules applied in this tender?

Local sourcing norms apply, requiring bidders to ensure a percentage of materials and labor are sourced locally, thereby supporting the local economy and contributing to sustainable practices.