Hindustan Aeronautics Limited Sukhoi Engine Division procurement 2025 - Defence Production security equipment tender HAL Odisha
Hindustan Aeronautics Limited (hal)
KORAPUT, ODISHA
Progress
Quantity
53
Category
620-EL1522
Bid Type
Two Packet Bid
Hindustan Aeronautics Limited (hal) has released a public tender for 620-EL1522, 620-EL1523, 620-EL1242, 620-EL1234, 620- EL1235 in KORAPUT, ODISHA. Quantity: 53. Submission Deadline: 01-07-2026 21: 00: 00. Download documents and apply online.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
620-EL1522 , 620-EL1523 , 620-EL1242 , 620-EL1234 , 620- EL1235
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Hindustan Aeronautics Limited (hal)
KORAPUT, ODISHA
Bharat Heavy Electricals Limited (bhel)
Indian Navy
Indian Navy
MUMBAI, MAHARASHTRA
Bharat Heavy Electricals Limited (bhel)
BANGALORE, KARNATAKA
Tender Results
Loading results...
620-EL1522
PANEL MOUNTED MCCB RATED CURRENT- 63AMPS NO. OF POLES- 03 ULTIMATE SHORT CIRCUIT BREAKING CAPACITY(Icu)AT 415VAC50/60 HZ- 35KA OR BETTER SERVICE BREAKING CAPACITY(Ics)- 100% OF Icu ADJUSTABLE OVERLOAD AND ADJUSTABLE SHORT CIRCUIT SETTING FOR LINE PROTECTION ADJUSTABLE THERMAL and ADJUSTABLE MAGNETIC PROTECTION
620-EL1523
PANEL MOUNTED MCCB RATED CURRENT- 100AMPS NO. OF POLES- 03 ULTIMATE SHORT CIRCUIT BREAKING CAPACITY(Icu)AT 415VAC50/60 HZ- 35KA OR BETTER SERVICE BREAKING CAPACITY(Ics)- 100% OF Icu ADJUSTABLE OVERLOAD AND ADJUSTABLE SHORT CIRCUIT SETTING FOR LINE PROTECTION ADJUSTABLE THERMAL and ADJUSTABLE MAGNETIC PROTECTION
620-EL1242
PANEL MOUNTED MCCB RATED CURRENT- 125AMPS NO. OF POLES- 03 ULTIMATE SHORT CIRCUIT BREAKING CAPACITY(Icu)AT 415VAC50/60 HZ- 35KA OR BETTER SERVICE BREAKING CAPACITY(Ics)- 100% OF Icu ADJUSTABLE OVERLOAD AND ADJUSTABLE SHORT CIRCUIT SETTING FOR LINE PROTECTION ADJUSTABLE THERMAL and ADJUSTABLE MAGNETIC PROTECTION
620-EL1234
PANEL MOUNTED MCCB RATED CURRENT- 160AMPS NO. OF POLES- 03 ULTIMATE SHORT CIRCUIT BREAKING CAPACITY(Icu)AT 415VAC50/60 HZ- 35KA OR BETTER SERVICE BREAKING CAPACITY(Ics)- 100% OF Icu ADJUSTABLE OVERLOAD AND ADJUSTABLE SHORT CIRCUIT SETTING FOR LINE PROTECTION ADJUSTABLE THERMAL and ADJUSTABLE MAGNETIC PROTECTION
620-EL1235
PANEL MOUNTED MCCB RATED CURRENT- 250AMPS NO. OF POLES- 03 ULTIMATE SHORT CIRCUIT BREAKING CAPACITY(Icu)AT 415VAC50/60 HZ- 35KA OR BETTER SERVICE BREAKING CAPACITY(Ics)- 100% OF Icu ADJUSTABLE OVERLOAD AND ADJUSTABLE SHORT CIRCUIT SETTING FOR LINE PROTECTION ADJUSTABLE THERMAL and ADJUSTABLE MAGNETIC PROTECTION
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | 620-EL1522 | PANEL MOUNTED MCCB RATED CURRENT- 63AMPS NO. OF POLES- 03 ULTIMATE SHORT CIRCUIT BREAKING CAPACITY(Icu)AT 415VAC50/60 HZ- 35KA OR BETTER SERVICE BREAKING CAPACITY(Ics)- 100% OF Icu ADJUSTABLE OVERLOAD AND ADJUSTABLE SHORT CIRCUIT SETTING FOR LINE PROTECTION ADJUSTABLE THERMAL and ADJUSTABLE MAGNETIC PROTECTION | 9 | nos | [email protected] | 70 | |
| 2 | 620-EL1523 | PANEL MOUNTED MCCB RATED CURRENT- 100AMPS NO. OF POLES- 03 ULTIMATE SHORT CIRCUIT BREAKING CAPACITY(Icu)AT 415VAC50/60 HZ- 35KA OR BETTER SERVICE BREAKING CAPACITY(Ics)- 100% OF Icu ADJUSTABLE OVERLOAD AND ADJUSTABLE SHORT CIRCUIT SETTING FOR LINE PROTECTION ADJUSTABLE THERMAL and ADJUSTABLE MAGNETIC PROTECTION | 10 | nos | [email protected] | 70 | |
| 3 | 620-EL1242 | PANEL MOUNTED MCCB RATED CURRENT- 125AMPS NO. OF POLES- 03 ULTIMATE SHORT CIRCUIT BREAKING CAPACITY(Icu)AT 415VAC50/60 HZ- 35KA OR BETTER SERVICE BREAKING CAPACITY(Ics)- 100% OF Icu ADJUSTABLE OVERLOAD AND ADJUSTABLE SHORT CIRCUIT SETTING FOR LINE PROTECTION ADJUSTABLE THERMAL and ADJUSTABLE MAGNETIC PROTECTION | 13 | nos | [email protected] | 70 | |
| 4 | 620-EL1234 | PANEL MOUNTED MCCB RATED CURRENT- 160AMPS NO. OF POLES- 03 ULTIMATE SHORT CIRCUIT BREAKING CAPACITY(Icu)AT 415VAC50/60 HZ- 35KA OR BETTER SERVICE BREAKING CAPACITY(Ics)- 100% OF Icu ADJUSTABLE OVERLOAD AND ADJUSTABLE SHORT CIRCUIT SETTING FOR LINE PROTECTION ADJUSTABLE THERMAL and ADJUSTABLE MAGNETIC PROTECTION | 8 | nos | [email protected] | 70 | |
| 5 | 620-EL1235 | PANEL MOUNTED MCCB RATED CURRENT- 250AMPS NO. OF POLES- 03 ULTIMATE SHORT CIRCUIT BREAKING CAPACITY(Icu)AT 415VAC50/60 HZ- 35KA OR BETTER SERVICE BREAKING CAPACITY(Ics)- 100% OF Icu ADJUSTABLE OVERLOAD AND ADJUSTABLE SHORT CIRCUIT SETTING FOR LINE PROTECTION ADJUSTABLE THERMAL and ADJUSTABLE MAGNETIC PROTECTION | 13 | nos | [email protected] | 70 |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Bharat Heavy Electricals Limited (bhel)
📍 BANGALORE, KARNATAKA
Bharat Heavy Electricals Limited (bhel)
📍 BANGALORE, KARNATAKA
Madras Fertilizers Limited (mfl)
📍 TIRUVALLUR, TAMIL NADU
Indian Navy
Hindustan Aeronautics Limited (hal)
📍 Rangareddi, TELANGANA
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS