TenderDekho Logo
Closed GEM

Bids are Invited For SITC OF HI-WALL SPLIT SYSTEMS,COPPER REFRIGERANT PIPING FOR 1.5TR AND 2.0TR HI-WALL SPLIT AC,DRAIN in KOLKATA, WEST BENGAL

Bid Publish Date

13-Aug-2026, 6:41 pm

Bid End Date

24-Aug-2026, 7:00 pm

EMD

₹7,000

Value

₹6,60,656

Progress

Issue13-Aug-2026, 6:41 pm
AwardPending

Public procurement opportunity for State Bank Of India (sbi) SITC OF HI-WALL SPLIT SYSTEMS, COPPER REFRIGERANT PIPING FOR 1. 5TR AND 2. 0TR HI-WALL SPLIT AC, DRAIN PIPE, OUTDOOR STAND FOR 1. 5TR AND 2. 0TR HI-WALL SPLIT AC, DISMANTLING OF OLD AC in KOLKATA, WEST BENGAL. Quantity: 323 issued by. Submission Deadline: 24-08-2026 19: 00: 00. View full details and respond.

Authority & Contact

Office Name

Kolkata

Grievance Contact

[email protected]

Tender Data

Bid Details

Quantity

323

Category

SITC OF HI-WALL SPLIT SYSTEMS

Bid Type

Two Packet Bid

Bid Validity

30 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

Tech Clarification Time

2 Days

Preference & Exemptions

EMD Required

Yes

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

MSE Exemption/Relaxation

No

Startup Exemption/Relaxation

No

Bid Splitting Applied

No

Requirements

OEM Avg. Turnover

20

Past Performance

80 %

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

SITC OF HI-WALL SPLIT SYSTEMS , COPPER REFRIGERANT PIPING FOR 1.5TR AND 2.0TR HI-WALL SPLIT AC , DRAIN PIPE , OUTDOOR STAND FOR 1.5TR AND 2.0TR HI-WALL SPLIT AC , DISMANTLING OF OLD AC

Advisory Bank

State Bank of India

Payment Timelines

Payments shall be made to the Seller within 30 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)

Delivery Details

Max Delivery Days

15

Delivery Locations

1

Delivery Cities

Kolkata

Delivery Pincodes

700001

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Souvagya Kumar Sahoo700001,LHO kolkata, 1 Strand Road, KolkataKolkataWest Bengal7000011115-

Authority Records

MINISTRY OF FINANCEFINANCIAL SERVICES DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 4

GeM-Bidding-9748279.pdf

Main Document

BOQ Document

BOQ

BOQ Document

BOQ

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Bill of Quantities (BOQ) 5 Items Sign in for GEM prices

#1

SITC OF HI-WALL SPLIT SYSTEMS

Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS - 1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Buy Back of OLD AC Units on wherein whereas basis.

11 set Delivery: 10 days
#2

COPPER REFRIGERANT PIPING FOR 1.5TR AND 2.0TR HI-WALL SPLIT AC

Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessoriesas per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 1.5 TR HI WALL SPLIT

150 mtr Delivery: 10 days
#3

DRAIN PIPE

Supply and fixing of duly insulated 25mm UPVC drain pipe

140 mtr Delivery: 10 days
#4

OUTDOOR STAND FOR 1.5TR AND 2.0TR HI-WALL SPLIT AC

Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 TR Hi-Wall Split AC.

11 set Delivery: 10 days
#5

DISMANTLING OF OLD AC

Dismantling of existing air conditioner

11 set Delivery: 10 days

Categories 76

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

OEM Authorization Certificate

5

OEM Annual Turnover

6

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

7

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer