TenderDekho Logo
Closed GEM

Open Tender for Neonatal Ventilators in CENTRAL DELHI, DELHI

Bid Publish Date

06-Aug-2026, 11:44 am

Bid End Date

28-Aug-2026, 12:00 pm

EMD

₹5,00,000

Value

₹3,30,00,000

Progress

Issue06-Aug-2026, 11:44 am
AwardPending

Lady Hardinge Medical College New Delhi has released a public tender for Neonatal Ventilators (Q2) in CENTRAL DELHI, DELHI. Quantity: 6. Submission Deadline: 28-08-2026 12: 00: 00. Download documents and apply online.

Authority & Contact

Tender Data

Bid Details

Quantity

6

Bid Type

Two Packet Bid

Bid Validity

180 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

RA Qualification Rule

H1-Highest Priced Bid Elimination

Tech Clarification Time

3 Days

Preference & Exemptions

EMD Required

Yes

MII Purchase Preference

No

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

MSE Exemption/Relaxation

Yes

Startup Exemption/Relaxation

Yes

Bid Splitting Applied

No

Requirements

Past Performance

30 %

Warranty Period

2 years

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Neonatal Ventilators (Q2)

Advisory Bank

Bank Of Baroda

ePBG Percentage

5%

ePBG Duration (Months)

30

Pre-Bid & Qualification

Pre-Bid Date

08-08-2026 11:00:00

Pre-Bid Venue

Office of Addl. Medical Superintendent, Ground Floor, old SSKH Building, Kalawati Saran Children's Hospital, New Delhi

Delivery Details

Max Delivery Days

45

Delivery Locations

1

Delivery Cities

New Delhi

Delivery Pincodes

110001

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Ajay Wadhawan110001,Kalawati Saran Children Hospital, Bangla Sahib Marg, New DelhiNew DelhiDelhi110001645-

Authority Records

MINISTRY OF HEALTH AND FAMILY WELFAREHEALTH AND FAMILY WELFARE DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 6

GeM-Bidding-9716115.pdf

Main Document

Other Documents

OTHER

CATALOG-Specification-1

CATALOG Specification

Other Documents

OTHER

Other Documents

OTHER

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Required Documents

1

Experience Criteria

2

Past Performance

3

Certificate (Requested in ATC)

4

OEM Authorization Certificate

5

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

6

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
PERFORMANCE PARAMETERS Patient Type Neonatal, Premature
PERFORMANCE PARAMETERS Tidal Volume Range In ml 2 to 300, 2 to 700
PERFORMANCE PARAMETERS Trigger Sensitivity Mechanism Pressure, Flow, Pressure and Flow
PERFORMANCE PARAMETERS Flow Pattern/Waveform Adjustment Yes, No
PERFORMANCE PARAMETERS Sigh Breath Function Yes, No
PERFORMANCE PARAMETERS Leak Compensation Available Yes, No
PERFORMANCE PARAMETERS Auto 100% increase O2 Button Yes, No
PERFORMANCE PARAMETERS Inspiratory Pause Available Yes, No
PERFORMANCE PARAMETERS Expiratory Hold Available Yes, No
PERFORMANCE PARAMETERS Suction Control Option Available Yes, No
PERFORMANCE PARAMETERS Nasal CPAP Option Available Yes, No
PERFORMANCE PARAMETERS Auto PEEP Manoeuvre Yes, No
PERFORMANCE PARAMETERS Control Panel Lock Yes, No
PERFORMANCE PARAMETERS Facility for double lung ventilation Yes, No
PERFORMANCE PARAMETERS Integrated Air Compressor Yes, No
VENTILATION MODES PSV(Pressure supported ventilation) Yes, No
VENTILATION MODES P-CMV(Inspiration pressure control) Yes, No
VENTILATION MODES PC-AC With Expiratory Minimal volume Yes, No
VENTILATION MODES SIMV(Synchronized intermittent Mandatory Ventilation) with PCMV Yes, No
VENTILATION MODES ITT - Inspiratory Time Termination Yes, No
VENTILATION MODES CPAP:Continuos Positive Airway pressure Ventilation CPAP With backup Ventilation Yes, No
VENTILATION MODES High Frequency Oscillation Ventilator(HFOV) Yes, No
PATIENT ASSESSMENT TOOLS Capnography/Co2 Monitoring Yes, No
PATIENT ASSESSMENT TOOLS Volume Guarantee Yes, No
PATIENT ASSESSMENT TOOLS APRV Yes, No
PATIENT ASSESSMENT TOOLS Oxygen Therapy Yes, No
ADDITIONAL CAPABILITIES ETCO2 Inbuilt available Yes, No
HUMIDIFIER Disposable Neonatal breathing circuit (dual heated wire) 20, 50, 80, 100, NA
HUMIDIFIER Auto Feed Humidification chamber Available Yes, No
HUMIDIFIER Disposable Neonatal breathing circuit with single heated wire provided for inspiratory Limb with Water trap in expiratory limb available 20, 50, 80, 100, NA
ADDITIONAL PARAMETERS Output Ports Type HDMI, Ethernet, RJ 45, USB
ADDITIONAL PARAMETERS Remote Alarm Display Port Yes, No
ADDITIONAL PARAMETERS Reporting (Vent alarms and Patient Status) Yes, No
ADDITIONAL PARAMETERS View Reports on Display Yes, No
ADDITIONAL PARAMETERS Save Data to USB Yes, No
ADDITIONAL PARAMETERS Send Data Via Network Yes, No
ADDITIONAL PARAMETERS Display Type LCD/LED/TFT
ADDITIONAL PARAMETERS Display Size in Inches ≥ 10, ≥ 12, ≥ 15 Or higher
ADDITIONAL PARAMETERS Can be used For Patient Transport Yes, No
ACCESSORIES Nasal CPAP Kit 10, 15, 20
ACCESSORIES Number of Disposable flow sensor 20, 50, 100, NA if Reusable
ACCESSORIES Number of Reusable flow sensor 3, 6, NA if Disposable
ACCESSORIES Trolley with ventillator with supporting arm from same manufacturer Yes, No
ACCESSORIES Autoclavable exhalation valve/expiratory cassette 2, 3
ACCESSORIES Test Lung Available Yes
POWER REQUIREMENTS Operating time of battery in min 30, 60, 120